• 제목/요약/키워드: Noise and vibration test

검색결과 1,768건 처리시간 0.028초

HDD의 소음도 평가에 대한 연구 (Research on evaluation for the noise of HDD)

  • 최성준;문원규;강성우;황태연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.543-548
    • /
    • 2002
  • Nowadays since the customers of HDD's are interested in their noise levels in addition to their primary performances such as their average access time, capacity, HDD manufacturers make efforts on reducing the noise. The works to reduce noise are usually based on the measurable physical quantities such as SPL or acoustic intensity level. However, since the HDD noise is Judged by human beings, the basis of noise reduction should be human sensations. In this paper, the noise levels of various HDD's are evaluated by the human jury test to find a relationship between the physical quantities used for noise control and the human sensations of noise. Discrepancies are found in the judgments by the human beings and by the physical quantities. The loudness level, a psychoacoustic variable, is used to solve the discrepancy.

  • PDF

마이크로폰 어레이 측정에서의 도플러 효과와 자체소음 제거에 관한 실험적 연구 (Elimination of Self Noise & Doppler Effects from the Microphone Array Measurement)

  • 이욱;박성;김재무;최종수
    • 한국소음진동공학회논문집
    • /
    • 제16권7호
    • /
    • pp.677-682
    • /
    • 2006
  • In the case of aeroacoustic test in windtunnel, measurement accuracy is reduced by not only Doppler effects but also by the microphone self noise due to airflow and high turbulence in the wall boundary layer. Microphone array measurements can be easily utilized for the solutions of these problems. In this paper, geometrical optics approach and diagonal term elimination of cross spectral matrix was introduced to the de-dopplerization and self noise reduction methods for the microphone array measurement. For the validation, beamforming tests for sinusoidal point source were performed in the closed type test section of windtunnel, and their performances of beam width and sidelobe rejection were significantly improved.

마이크로폰 어레이 측정에서의 도플러 효과와 자체소음 제거에 관한 실험적 연구 (Elimination of Self Noise & Doppler Effects from the Microphone Array Measurement)

  • 이욱;박성;최종수;김재무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.822-825
    • /
    • 2005
  • In the case of aeroacoustic test in windtunnel, measurement accuracy is reduced by not only Doppler effects but also by the microphone self noise due to airflow and high turbulence in the wall boundary layer. Microphone array measurements can be easily utilized for the solutions of these problems. In this paper, geometrical optics approach and diagonal term elimination of cross spectral matrix was introduced to the de-dopplerization and self noise reduction methods for the microphone array measurement. For the validation, beamforming tests for sinusoidal point source were performed in the closed type test section of windtunnel, and their performances of beam width and sidelobe rejection were significantly improved.

  • PDF

건물을 통과하는 도로의 방진설계 연구 (A Study on the Vibration Isolation Design of Road Passing through Building)

  • 맹주원;권태철;이성춘;홍갑표
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.760-765
    • /
    • 2003
  • This study is performed in order to determine a method to solve vibration-borne problems by isolating the vibration that is generated by vehicles in case a road passes through a building and also to verify its applicability and effect both theoretically and experimentally.

  • PDF

대형 잔향실의 방진 구조 설계 및 검증시험 (Design and Verification of a Large Reverberation Chamber's Isolation System)

  • 김홍배;이득웅
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1066-1074
    • /
    • 2004
  • A vibration isolation system for a large reverberation chamber (1,228 $m^3$ and 1,000 ton) has been installed and verified. The reverberation chamber generates loud noise and induces high level of vibration while performing spacecraft acoustic reliability tests. The isolation system prevents vibration transfer from the chamber to the enclosure buildings. This paper describes design process and commissioning experiments of the system. Design criteria have been derived from rigid body model of the chamber. The stiffness of neoprene pads has been selected by employing finite element analysis of the reverberant chamber and isolation system. A total of 21 neoprene pads have been installed between the chamber and supporting Pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. While 136.9 dB noise is generated in the chamber, absolute transmissibility of the isolation system has been measured. The measured natural frequency of the chamber is 10.2Hz, which is 80% of the predicted value. Overall transmissibility at working frequency range (25∼10.000 Hz) is less than -12.4 dB.

충격식 피로시험기 개발 (Development of Impact Fatigue Test Machine)

  • 남용윤;신병천;홍석균;이성우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1154-1160
    • /
    • 2000
  • This paper reports the development of a special impact fatigue test machine for high pressure vessels. The targeted vessels are subjected to shock pressures equivalent of explosions. This severe loading condition brings many difficulties to the design of test machine. Unfortunately, there are very rare such test machine in the world, and more worse, the machine is not opened and sold.

  • PDF