DOI QR코드

DOI QR Code

Design and Verification of a Large Reverberation Chamber's Isolation System

대형 잔향실의 방진 구조 설계 및 검증시험

  • Published : 2004.11.01

Abstract

A vibration isolation system for a large reverberation chamber (1,228 $m^3$ and 1,000 ton) has been installed and verified. The reverberation chamber generates loud noise and induces high level of vibration while performing spacecraft acoustic reliability tests. The isolation system prevents vibration transfer from the chamber to the enclosure buildings. This paper describes design process and commissioning experiments of the system. Design criteria have been derived from rigid body model of the chamber. The stiffness of neoprene pads has been selected by employing finite element analysis of the reverberant chamber and isolation system. A total of 21 neoprene pads have been installed between the chamber and supporting Pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. While 136.9 dB noise is generated in the chamber, absolute transmissibility of the isolation system has been measured. The measured natural frequency of the chamber is 10.2Hz, which is 80% of the predicted value. Overall transmissibility at working frequency range (25∼10.000 Hz) is less than -12.4 dB.

Keywords

References

  1. A High Intensity Acoustic Chamber for Spacecraft Environmental Tests Kim, Y. K.;Kim, H. B.;Moon, S. M.;Woo, S. H
  2. 한국소음진동공학회, 춘계학술대회논문집 다목적 실용위성 2호 구조 - 열 모델의 음향환경 시험 김홍배;문상무;김성훈;우성현;이상설
  3. ISO3743 Precision Measurement of Sound Power at a Reverberant Acoustic Chamber
  4. Shock and Vibration Handbook Crede, Charles E.;Ruzicka , Jerome E.
  5. Mechanical Vibrations(Second Edition) Rao, Singiresu S.
  6. 한국소음진동공학회논문집 v.13 no.3 적응 삼각형 빔 방법에 의한 실내음장 해석 조대승;성상경;김진형;최재호;박일권 https://doi.org/10.5050/KSNVN.2003.13.3.217