• Title/Summary/Keyword: Noise Regulation

Search Result 212, Processing Time 0.023 seconds

Development of Lower Noise Excavator (굴삭기 저소음화 기술개발)

  • Ko, Kyung-Eun;Kim, Young-Hyun;Joo, Won-Ho;Kim, Dong-Hae;Bae, Jong-Gug;Shim,, Jae-Koo;Kang, Jeong-Weon;Son, Deuk-Kyun;Kim, Choon-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.156-160
    • /
    • 2005
  • The radiated noise of the excavator is composed of the various noise sources such as the diesel engine, cooling fan and hydraulic system, so the noise reduction for each noise source is required. In this study, the source contribution analysis for these principal noise sources is performed by using the noise source removal method. And to reduce the noise due to each one, the various experiments and analyses are studied. On the basis of these results, the proper reduction countermeasures are derived to develop the excavator satisfied the $2^{nd}$ noise regulation of EU.

  • PDF

Study on Effective Noise Management Plan of Construction Site (건설공사장의 효율적인 소음관리방안을 위한 연구)

  • Sun, Hyo-Sung;Park, Young-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.176-183
    • /
    • 2009
  • The objective of this study is to prepare the plans for managing construction noise effectively and solving the popular enmity from construction noise reasonably. In order to carry out this purpose, it covers the efficient improvement plans for adjusting the construction noise regulation standard rationally and managing the automatic noise measuring system which shows the advantage for construction noise management and popular enmity solution due to construction noise. The three alternative plans of the construction noise regulation standard and the recommendation plan including the guideline for installing and managing the automatic noise measuring system are suggested consequently.

A Study on Outdoor Acoustic Noise for HVDC Converter Station (HVDC 변환소의 옥외소음 분석)

  • Lee, Seong-Doo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.91-99
    • /
    • 2010
  • HVDC converter station consists of a number of equipment such as converter transformer, ac filter, thyristor valve and so on. They can be acoustic noise sources. In this paper, we analyzed the simulation results of the outdoor acoustic noise for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasures in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

Analysis of Acoustic Noise Characteristics of Jindo-Cheju HVDC (진도-제주 HVDC 변환설비 소음특성 분석)

  • Kim, Jae-Han;Kim, Chan-Ki;Lee, Seong-Doo;Kim, Jin-Young
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.574-576
    • /
    • 2010
  • HVDC converter station consists of a number of noise sources such as converter transformer, ac filter, cooling system and so on. In this paper, we analyzed the simulation results of the outdoor acoustic noise characteristics for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasure in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

  • PDF

Estimation of the Motor Vehicle Noise Emission based on Amendments of European Regulation R51 (ECE R51 자동차주행소음 규정의 개정에 따른 자동차 소음 평가)

  • Park, Jin-Woo;Cho, Sang-Soo;Shin, Jae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.783-787
    • /
    • 2007
  • Nowadays, vehicle becoming necessity is increasing gradually and is main cause of environmental problem. The current automobile noise measurement test method such as ISO 362 which have been used many countries contribute seriously to enforce the regulation of the noise rigidly and actively study vehicle's noise, using that method. However, the amendment of ISO 362 was completed under the international agreement due to the changes in vehicle's techniques and road conditions. In this study, the difference between the current ISO 362(or ECE R51) and new ISO 362(or new ECE R51) is estimated by the test using the practical car producing domestically because the Korean manufacturer have to be interested in new test method.

  • PDF

Pass by Noise Test Site Variability

  • Kim Byoung Sam
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.116-121
    • /
    • 2005
  • The objective of this paper is to compare the site-to-site variability of ISO 10844 pass by the noise test sites. In order to investigate the site-to-site variance of test surfaces, European commercial tires are tested at seven different test sites. Three Korea test sites and four Europe test sites are selected. The pass by noise test is done according to a 2001/43/EC regulation. Although the ISO surface has a very specific track composition, it does not reduce the variation of pass by noise measurements over the surface of test sites. This paper shows that the test results of pass by noise level are different depending on the test sites. The correlation obtained in this work is able to predict the pass by noise level for certain test site using the data measured from another test site. The prediction value is range with an error within 1dB(A).

Expansion Joints for Vibration and Noise Test (신축이음장치의 진동소음 실험)

  • Kwark, Jong-Won;Kim, Young-Jin;Lee, Jung-Woo;Choi, Eun-Suk;Chin, Won-Jong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.513-516
    • /
    • 2004
  • Consistency in design, manufacture, installation and performance test of expansion joints is insufficient for guarantee of reliability because they are imported from various foreign countries as America, Japan and Europe. In addition to that, the regulations or codes of expansion joint should be revised and established for levels of vibration and noise generated from riding vehicles especially. Regulation on the noise neighboring traffic roads is established by ministry of environment. Therefore, Field tests on the vibration and the noise at expansion Joints, especially rail-type and finger-type joints which are typical ones in bridge with short or middle span, are performed and performance of expansion joints are analyzed. And so, the results of the investigation will be utilized as basic data for the regulation on the vibration and the noise.

  • PDF

Development of Lower Noise Excavator (굴삭기 저소음화 기술개발)

  • Ko, Kyung-Eun;Kim, Young-Hyun;Joo, Won-Ho;Kim, Dong-Hae;Bae, Jong-Gug;Shim, Tae-Koo;Kang, Jeong-Weon;Son, Deuk-Kyun;Kim, Choon-O
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.12 s.117
    • /
    • pp.1185-1191
    • /
    • 2006
  • The radiated noise of the excavator is composed of the various noise sources such as the diesel engine, cooling fan and hydraulic system, so the noise reduction for each noise source is required. In this study, the source contribution analysis for these principal noise sources is performed by using the noise source removal method. And to reduce the noise due to each one, the various experiments and analyses are studied. On the basis of these results, the proper noise reduction countermeasures are derived to develop the excavator satisfied the $2^{nd}$ noise regulation of EU.

Low Drop Out Regulator with Ripple Cancelation Circuit (잡음 제거 회로를 이용한 LDO 레귤레이터)

  • Kim, Chae-Won;Kwon, Min-Ju;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.264-267
    • /
    • 2017
  • In this paper, A low dropout (LDO) regulator that improves the power supply rejection ratio by using a noise canceling circuit is proposed. The noise rejection circuit between the error amplifier and the pass transistor is designed to reduce the influence of the pass transistor on the noise coming from the voltage source. The LDO regulator has the same regulation characteristics as the conventional LDO regulator. The proposed circuit uses 0.18um process and Cadence's Virtuoso and Specter simulator.