• 제목/요약/키워드: Noise Reduction Barrier

검색결과 93건 처리시간 0.024초

현장 적용성을 향상시킨 건설현장 소음예측프로그램 개발 (Development of the Noise Prediction Program to apply in Construction Site)

  • 오진균;박혜나;손장열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.302-309
    • /
    • 2009
  • Nowadays, the construction sites are growing in city every year, so complaints for construction noise have increased more and more. To analyze this noise scientifically, construction noise prediction program was developed in 1998 and 2005 but it is too difficult to apply program in field because there is few soundproof facilities and it can't understand the coordinate system and so on. The aim of this study is to develop noise prediction program to apply in construction sites. For this, the problems of existing program was analyzed and survey was performed to get requestion of field overseer and upgraded program. To get reliability of program, it was compared with sound measurement value in field. As a result, construction sound prediction program have various soundproof facilities data than existing program. It can also analyze multi receiver point at the same time for several construction machinery. Most of all, it is more powerful to set receiver or source in the axis of X, Y, Z. so program user can make use of it easily. An average of difference is -0.9$\sim$1.8dB.

  • PDF

현장 적용성을 향상시킨 건설현장 소음예측프로그램 개발 (Development of the Noise Prediction Program to apply in Construction Site)

  • 오진균;박혜나;손장열
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.409-417
    • /
    • 2009
  • Nowadays, the construction sites are growing in city every year, so complaints for construction noise have increased more and more. To analyze this noise scientifically, construction noise prediction program was developed in 1998 and 2005 but it is too difficult to apply program in field because there is few soundproof facilities and it can't understand the coordinate system and so on. The aim of this study is to develop noise prediction program to apply in construction sites. For this, the problems of existing program was analyzed and survey was performed to get requestion of field overseer and upgraded program. To get reliability of program, it was compared with sound measurement value in field. As a result, construction sound prediction program have various soundproof facilities data than existing program. It can also analyze multi receiver point at the same time for several construction machinery. Most of all, it is more powerful to set receiver or source in the axis of X, Y, Z. so program user can make use of it easily. An average of difference is -0.9~1.8 dB.

건설공사장 이동식 방음시설물의 음향특성 (Site Mitigation Plan for Noise Sources from Construction Sites by Developing Movable Noise Barriers)

  • 이성찬;정진연;임정빈
    • 한국소음진동공학회논문집
    • /
    • 제25권1호
    • /
    • pp.58-64
    • /
    • 2015
  • There are a lot of different types of noise from construction site and it depends on construction stage, equipment type and number of operating equipments. The problem is that the almost noise from construction site is high level and some kinds of noise levels are over 100 dB. In addition, if construction site is located in downtown, there are a few options to reduce noise level. Therefore several site mitigation plans were developed to reduce different types of construction noises such as breaker work, gang form and asphalt saw. They were applied in site and evaluated noise reduction performance. The test result of site insertion loss was between 4~8 dB depends on the equipment and type of work.

인클러져 개구부 투과소음 능동제어 (Active Control of Transmitted Noise through Opening of Enclosures)

  • 이한울;홍진숙;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.733-738
    • /
    • 2012
  • This paper presents active noise control for the reduction of transmission noise passing through opening of enclosures. Enclosures are essential measure to protect noise propagation from operating machinery. Access openings of the enclosures are important path of noise leakage. First, we modeled and analyzed the noise characteristics passing through the openings of the enclosure generated by the operation of the machinery based on the finite element method. We then implemented a feedforward controller to actively control the acoustic power through the opening. Finally, we conducted optimization of placement of the reference sensors for several cases of the number of sensors. A good control performances were achieved using a minimum number of microphones arranged a optimal placement.

  • PDF

도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구 (A study on Traffic Noise control by the Environmental facilities around Roadway)

  • 설증민;정용
    • 환경위생공학
    • /
    • 제3권2호
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

공명 원리를 이용한 흡음벽에 관한 연구 (A Study on the Acoustic Absorption Panel by the Theory of Resonator)

  • 유영훈;이종근
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2006년도 추계학술발표회
    • /
    • pp.125-129
    • /
    • 2006
  • 사람의 청각에 영향을 미치는 구역에 설치된 가전용품 및 기계에서 발생하는 소음을 저감하는 것은 중요하다. 특히 선박의 기관실에서 발생하는 소음은 저감이 불가능한 것으로 알려져 개선의 정도가 미미할 뿐 아니라 작업자의 청력손실이 발생하는 최악의 작업환경에 놓여져 있는 실정이다. 그러나 최근에 발전되고 있는 모니터링설비와 지능제어시스템을 이용하면 기관실의 주 엔진을 개방 해 둘 필요가 없어지게 되었다. 따라서 주 엔진의 주변을 흡음 및 차음벽으로 차단하여 기관실의 소음을 개선할 수 있는 계기가 되고 있다. 본 연구에서는 소음을 흡수할 수 있는 차음벽의 성능을 높이기 위해 헬름홀츠 공영기의 원리를 적용한 흡음벽에 대하여 연구하였다.

  • PDF

변압기 소음제어를 위한 다중채널 능동소음제어 시스템 (A Multi-Channel Active Noise Control System for Controlling Humming Noise Generated by a Transformer)

  • 이혁재;박영철;윤대희;차일환
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1137-1144
    • /
    • 1999
  • Most of ANC(active noise control) researches are focused on adaptive algorithms, computer simulations and implementations of single-channel system in experimental environments. In this paper, a multi-channel ANC system based on DSP's was developed to obtain global attenuations over wide region and applied to the active control of the humming noise generated by a transformer. The developed ANC system including 24 microphones and 12 spearkers was applied to the real transformer noise reduction problem. Results showed that the control system could successfully control the humming noise over the region of interest.

  • PDF

터널 발파소음 감쇠를 위한 방음시스템 개발 (The Development of Soundproof System for the Blasting Noise Reduction in Tunnels)

  • 노상림;김욱영;조영천;이상필;유지영
    • 화약ㆍ발파
    • /
    • 제22권1호
    • /
    • pp.67-74
    • /
    • 2004
  • 도심지 지역의 발파는 건설 공사장 주변의 주민들에게 많은 소음을 초래하므로 우리의 생활에 중요한 화제로 대두되고 있다. 따라서 발파소음을 줄일 수 있는 방법의 개발이 매우 절실한 것이 현실이지만, 발파소음의 실제적인 저감법을 찾는 것은 기본데이터의 부족과 현상연구의 부족으로 인하여 매우 어렵다. 기존 방음벽의 한계를 극복하기 위하여, 새로운 재료의 다층 방음시스템을 개발하여 국사봉 터널 현장에 적용하였으며 여기에서 얻은 소음데이터를 통계적인 방법으로 분석하였다. 이러한 일련의 과정을 통하여, 본 연구에서 개발한 방음시스템이 발파소음을 저감시키는데 매우 유용하다는 것을 확인하였다.

Comparison of Transfer Function Method and Reverberation Room Method in Measuring the Sound Absorption Coefficient of Rice Straw Particle Mat

  • Kang, Chun-Won;Jang, Eun-Suk;Jang, Sang-Sik;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권4호
    • /
    • pp.362-367
    • /
    • 2018
  • This study estimates the sound absorption capability of rice straw particle mats by two methods: the transfer function method and the reverberation room method. In the reverberation method, the central frequency was set to the one-third octave band in the 100-5000 Hz range; in the transfer function method, the frequency range was 500-6400 Hz. Both methods yielded similar noise reduction coefficients of the rice straw mats. The noise reduction coefficient was approximately 0.8, indicating a high sound-absorption property of the mats. Therefore, rice straw matting is a suitable candidate material for sound-barrier walls against highway noise.

대형 변압기의 밀폐장치용 소음기 개발 (Development of a Silencer for an Acoustic Enclosure of a Large Transformer)

  • 이준신;이욱륜;이대성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.786-789
    • /
    • 2005
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build up inside the enclosed acoustic field. In general, a silencer is installed to overcome these limitations, for large amount of air can be exchanged through the silencers. In this reason, a parallel baffle type duct silencer with acoustic resonators is studied to reduce the transmitted noise from a transformer. In this silencer, the high frequency components of the transmitted noise over 360Hz are effectively absorbed by the parallel baffles and the other ones, 120 and 240 Hz, are reduced due to the presence of Helmholtz resonators. Large sound attenuation is achieved by applying the sound resonating barrier to the large transformers in a substation.

  • PDF