• 제목/요약/키워드: Noise Reduction Barrier

검색결과 93건 처리시간 0.021초

방음벽의 유피관리 실태 및 개선방안에 관한 연구 (Actual Status and Improvement Method of Maintenance Management for Noise Barrier)

  • 김흥식;허영
    • 한국소음진동공학회논문집
    • /
    • 제13권7호
    • /
    • pp.570-576
    • /
    • 2003
  • Noise harriet Is used for noise reduction method of traffic noise. The length and the total cost of that are increased In this national area. But. a maintenance management of noise barrier is not systematic. and the guideline of that is not prepared for maintenance manual. The situations of existed installation and management of noise barriers Installed at 3.619 positions were investigated by questionnarie and direct field survey. And comparisons with foreign management guideline of noise harrier were carried out. The results show that the improvement methods of maintenance management system such as practical checklist and required Items for management of noise barrier were suggested.

음향공명 방음벽 연구 (A Study on the Sound Resonating Barrier)

  • 이준신;김태룡
    • 한국소음진동공학회논문집
    • /
    • 제12권6호
    • /
    • pp.413-419
    • /
    • 2002
  • Noise barriers are widely used to reduce the sound level propagating from highways, railways or factories to residential areas. The reduced noise level at a receiver point is then determined by the diffracted waves around the edge of the barrier as well as by the transmitted waves through the barrier. 1'or proper usage, many studies either theoretical or experimental have been made with the objective of precisely Predicting the acoustic field and improving the noise attenuating properties of barriers. In this study. a simple scattering model. a line acoustic source scattered by an infinite cylinder, is introduced to simply Investigate the sound attenuation efficiency of a sound-resonating barrier. From this model study, it is observed that the sound-resonating harrier can be used as a good sound-shielding element especially for the pure-tone noise generated from the transformer. Large sound-attenuation is achieved by applying the sound-resonating barrier to the large transformers in a substation.

400 km/h급 고속철도의 소음저감을 위해 방음벽 상부에 설치하는 소음저감장치 개발에 관한 연구 (A Study on the Development of a Noise Reduction Device Installed at the Top of Noise Barrier for the 400 km/h Class High-speed Railroad)

  • 윤제원;김영찬;장강석;홍병국;엄기영
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.823-830
    • /
    • 2013
  • The purpose of this study is to develop a noise reduction device installed at the top of noise barrier for further decreasing of noise level of 400 km/h class high-speed railroad. For this, the frequency spectrum of 400 km/h class high-speed railroad was analyzed through the field noise test, and the tuning frequency was determined to design a noise reduction device. The noise reduction device was designed to have noise reduction performance of at least 3 dB(A) using the prediction method(2D BEM) and through the laboratory test with the prototype. Finally, the outdoor test showed that this device could decrease noise level of 400 km/h class high-speed railroad even more than 3 dB(A).

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(3) - 시험 및 평가방법의 제안 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(3) - Suggestion of Test and Estimation Method -)

  • 김철환;장태순;강희만;전기성;김동준;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.496-499
    • /
    • 2008
  • The noise reducing devices installed on the noise barrier have been developed in many shapes and ways to reduce noise around road traffic areas. In this study, test and estimation method for the noise reducing device witch installed on the top of a noise barrier was suggested. For this, the authors have considered sound power flow around the device and sound pressure levels for the far field area. To estimate the area effect behind the barrier, area average of noise pressure level difference divided by two area, upper and bellow the sight-line. Comparing the attenuation difference of these areas, the tendency of noise reduction effect was studied according to type of noise reducing devices. Compared with noise shielding efficiency of the devices that using equivalent height of a simple barrier calculated by the SoundPlan, the commercial environment noise simulation software.

  • PDF

Reducing the wind pressure at the leading edge of a noise barrier

  • Han, Seong-Wook;Kim, Ho-Kyung;Park, Jun-Yong;Ahn, Sang Sup
    • Wind and Structures
    • /
    • 제31권3호
    • /
    • pp.185-196
    • /
    • 2020
  • A method to reduce the wind pressure at the leading edge of a noise barrier was investigated by gradually lowering the height of a member added to the end of the noise barrier. The shape of the lowered height of the added member was defined by its length and slope, and the optimal variable was determined in wind tunnel testing via the boundary-layer wind profile. The goal of the optimal shape was to reduce the wind pressure at the leading edge of the noise barrier to the level suggested in the Eurocode and to maintain the base-bending moment of the added member at the same level as the noise-barrier section. Using parametric wind tunnel investigation, an added member with a slope of 1:2 that protruded 1.2 times the height of the noise barrier was proposed. This added member is expected to simplify, or at least minimize, the types of column members required to equidistantly support both added members and noise barriers, which should thereby improve the safety and construction convenience of noise-barrier structures.

방음벽 상단의 소음감소기 성능 시험 (Performance Test of Noise Reducers Installed on Noise Barrier)

  • 강대준;이재원;구진회
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.388-391
    • /
    • 2006
  • The use of noise barrier is being increased to reduce the environmental noise in these days. Also, many noise reducers installed at the top of noise barrier are developed for improving the performance of noise reduction. So we evaluate the performance of the noise reducers and compare the results. Results of the field tests show that the insertion loss due to the noise reducers is up to 10.6 dB.

  • PDF

방음벽 상단의 소음감소기 성능 평가 (Performance Test of Noise Reducers Installed on Noise Barrier)

  • 강대준;이재원;구진회
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1139-1144
    • /
    • 2007
  • The use of noise barrier is being increased to reduce the environmental noise in these days. Also, many noise reducers installed at the top of noise barrier are developed for improving the efficiency of noise reduction. So we evaluate the performance of the noise reducers and compare the results among the others. Results of field tests show that the insertion loss due to the noise reducers is up to 10.6 dB.

방음벽 상단의 소음감소기 성능 평가 (Performance Test of Noise Reducers Installed on Noise Barrier)

  • 강대준;이재원;구진회
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.570-574
    • /
    • 2013
  • The use of noise barrier is being increased to reduce the environmental noise in these days. Also, many noise reducers installed at the top of noise barrier are developed for improving the efficiency of noise reduction. So we evaluate the performance of the noise reducers and compare the results among the others. Results of field tests show that the insertion loss due to the noise reducers is up to 10.6 dB.

  • PDF

방음벽 상단 소음저감장치의 감음성능 평가방법 연구 (A Study on the Test Method for Noise Reduction Devices Installed on the Noise Barriers)

  • 김철환;장태순;김득성;김동준;장서일
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.791-796
    • /
    • 2010
  • Installing noise barriers is the most common method for reducing the highway traffic noise to the road side residential area. After the report about edge potential concept of a noise barrier, various types of noise reducing devices(NRDs) called "noise reducers" have been suggested for getting more shielding effect on the top of highway noise barriers. But, it has been doubtful about effect of the NRDs in field because there was no appropriate and unified method to estimate the acoustic performance by using field measurement of the NRDs in Korea. In this study, the authors have considered to setup a practical method to test and estimate the acoustic performance of NRDs. For eliminating the noise reduction effect of the NRDs height itself, the source and measuring points are adjusted as highly as the NRDs height. For the frequency weighting in the estimation of the NRDs effect, the highway noise spectra were measured at asphalt and concrete road side and then averaged for a unit spectral parameter.

도로환경에 따른 최적의 방음벽 높이 산정식 연구 (Development of an Optical Height Formula for Noise Barrier Considering the Road Environment)

  • 임유진;문학룡
    • 한국도로학회논문집
    • /
    • 제17권4호
    • /
    • pp.63-68
    • /
    • 2015
  • PURPOSES : A study on the efforts to minimize the road traffic noise has been underway. An attempt has been made to measure the noise level using a noise map; however, the attempt is limited to certain areas only. In general, a noise barrier is employed to prevent road traffic noise; however, unplanned noise barriers developed without considering the surrounding environment, including excessively high walls, cause problems such as infringement on prospect right. Noise ceiling at daytime in Korea is 68 dB(A), which is relatively higher than in other countries. METHODS: The noise barrier used mainly for road noise reduction was analyzed to estimate the optimal height. Related variables such as road width, the height of the upper part, distance to the building, and angle (for instance, $30^{\circ}$). RESULTS : A formula to calculate the optical height of the noise barrier, considering the road environment (i.e., parameters such as road width and distance to building), was developed in this study in an attempt to mitigate the noise generated from the road. CONCLUSIONS : The formula to calculate the noise barrier is expected to lead to cost saving, accurate installation of barriers, and protection of the right of prospect.