• 제목/요약/키워드: Noise Rating

검색결과 156건 처리시간 0.028초

공동주택 생활소음의 통합 평가등급 설정 (Criteria for multiple noises in residential buildings uslng combined rating system)

  • 류종관;이평직;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.367-371
    • /
    • 2005
  • Social noise survey on multiple residential noises such as nut impact, air-borne, bathroom, drainage and traffic noises was conducted to investigate major variables affecting the overall satisfaction for noise environment The effect of individual noise perception on the evaluation of the overall noise environment was investigated through a questionnaire survey on annoyance, disturbance and noise sensitivity. Auditory experiments was also undertaken to determine noise level according to the percent of satisfaction for individual noise source. As a result of survey, it was found that satisfaction for floor impact noise most greatly affects the overall satisfaction for noise environment and annoyance most greatly affects the satisfaction for individual noise sources. Result of auditory experiment showed that the noise level of floor impact noise by bang machine, airborne, drainage and traffic noise corresponding to 50% satisfaction is 44dB($L_{i,Fmax,AW}$) and 40dBA, respectively.

  • PDF

음질을 기초한 교통소음의 척도화에 관한 연구 (A Study of the Evaluation Scale of Traffic Noise base on Sound Quality Index)

  • 허덕재;조경숙
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1280-1284
    • /
    • 2006
  • This paper describes the methodology for environmental assessments of traffic noise sources. An attempt is made to establish evaluation scale relationships between noise quality Parameters and subjective degrees annoyance. Subjective experimental was conducted to determine the subjective degrees annoyance that scaling score compare with reference and varieties noise source about modified traffic noises with $40{\sim}85dB$. Also a correlation analysis between noise rating index and satisfactory percentage of the noise dose response curves varied with response was conducted. As a result of study, subjective annoyance degree has not correlation of proportional linearity to the A weight noise level, but has correlation of proportional linearity to the index composed to loudness and tonality. It is suggested to be resonable level 4.9 (equivalence about 53dB) index on the out door noise limits for traffic noise and to be 6 step scale base on the linearity for evaluation traffic noise.

  • PDF

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • 제8권4호
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

함정의 실내소음 허용기준 설정을 위한 청감평가 및 분석 (Psycho-acoustic Evaluation and Analysis of the Indoor Noise in Cabins of a Naval Vessel to Specify its Allowable Limit)

  • 홍현수;심상렬;한형석
    • 한국소음진동공학회논문집
    • /
    • 제21권7호
    • /
    • pp.650-656
    • /
    • 2011
  • The noise inside a naval vessel is very important in considering the need for hearing protection, improving the working environment and maintaining good communications for crews living on board a naval vessel. The indoor noise of a ship usually is specified by the A-weighted sound pressure level, but other evaluating parameters are required to reflect human senses more effectively. This paper uses additional noise indices related to room acoustics, such as NR(noise rating), NC(noise criterion), RC(room criterion), PSIL(preferred speech interference level) and loudness level to evaluate the noise inside cabins on a naval vessel. Using these psychological noise indices, allowable limit of noise level in cabins is suggested through psycho-acoustic evaluation for the noise in cabins.

고소음 작업장에서 발생하는 기기소음 평가를 위한 어휘의 유형화 (Typicality of Vocabulary for evaluation on Instrument-Noise generated at Loud Noise Workplace)

  • 주덕훈;국정훈;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.242-247
    • /
    • 2007
  • After the Industrialization of 1960s, while it has greatly contributed to the industrial development owing to acceleration of mechanization, but it is real situation that the countermeasure to Noise Damage generating at the loud noise workshop is scarcely made. Especially, the Instrument-Noise made at factory and workplace is so shocking and repeatedly reiterating terrible noise that most of the spot workers are forcedly imposing such dangers as the severe unpleasant feeling and hearing impairments. On such point of view, this Research has attempted to extract the proper Rating Vocabulary in order for valuation on Instrument Noise made at the terrible noise-workplace, therefore it is considering that those extracted Vocabularies could be utilized as the useful materials for appraisal on Instrument Noise, also for establishment of Regulation-Standard with regard to Acoustic Psychology Experimentation and Instrument Noise.

  • PDF

화장실 배수관에 따른 배수소음 평가 (Rating of Noise Emission by Plumbing system in Bathroom)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.923-927
    • /
    • 2003
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by pipe material, wrapped pipe with glass wool and installed pipe height The characteristics of noise emission from drain-pipes is as follows. The noise reduction pipe in PVC can reduce noise levels in 7-10㏈ and the cast-iron pipe can reduce in 14㏈compared with the normal PVC pipe. In these days, the glass wool was used for preventing the burst and the noise reduction. But the glass wool for wrapping pipe is not effective to the noise reduction. The characteristics of noise emission from various installed pipe height were measured As the ceiling space of the remodeled building was raised, the noise level was troubled by increasing of the vertical pipe length.

  • PDF

Casing 부착 SIP공법에 의해 발생하는 항타소음의 전달 및 감쇠특성에 관한 연구 (A Study on the Characteristics of Propagation and Attenuation of Piling Noise by SIP Method with Casing)

  • 이병윤;윤해동;조원희;김재수
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.899-905
    • /
    • 1999
  • Construction equipment noise has caused much annoyance for a number of dwellers in nearby construction field and has become a very serious issure in our living environment. Therefore, in our country, a practical solution and a better method of reducing construction equipment noise are highly required in construction field. Practical solutions for the construction equipment noise, however, are very difficult because of the poorness of basic data and insufficiency of the existing research. Especially, in order to establish the sound insulation plan about pilling works noise with high sound pressure level and impactive, a real situation of sound characteristics about the noise of pilling works in foundation work demands more detail investigation. In this point, this study attempts to survey the characteristics of attenuation and propagation of construction equipment noise in pilling work using SIP(soil-cement injected precast pile) method with casing. And this study intends to get the basic data for establishment of a standard about construction noise.

  • PDF