• 제목/요약/키워드: Noise Level

검색결과 3,738건 처리시간 0.031초

전동차 외부소음 저감 방안 검토 (Review of the mitigations the exterior noise level of EMU)

  • 박길배;박희준;기호철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.666-671
    • /
    • 2014
  • To reduce the exterior noise level of EMU, there are several ways have been evaluated. The noise sources for the exterior noise level are the traction motor, driving gear and wheel/rail rolling noise. In this article, the ways to mitigate the noise issue for EMU have been investigated and especially the way to protect the noise radiation from the bogie area and wheel/rail rolling noise. The way to evaluate the effect of the side skirt has been reviewed. To install the side skirt, the interface between the side skirt and the carbody and bogie should be examined and the acoustic design of the side skirt will be evaluated.

  • PDF

근접 측정에 의한 K2 소총 사격음의 측정 (The Measurement of Firing Noise of K2 Rifle at Close Distance)

  • 이윤
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1123-1128
    • /
    • 2004
  • An experimental study on firing noise of K2 rifle was performed. Firing noises of K2 rifle were measured at close distance to rifle. Firing noise of K2 rifle which made in Korea, has not measured before. The measurement of firing noise at close distance is not simple, because the amplitude of firing noise is much bigger than the measuring limit of ordinary sound level meter even though it uses a signal attenuator. The measurement of firing noise at close distance is necessary for noise source positioning and for obtaining the sound power of K2 rifle. By this experimental study, the firing noise levels of K2 rifle at different positions are obtained and these data can be used to Predict the sound pressure level at any distance from muzzle of the rifle. Also these data can be used to calculate the threshold shift of gunner's ear.

공동주택 소음예측 방법에 관한 연구 (Study on the efficient noise prediction for an apartment house)

  • 고준희;김동준;박수진;장서일;조만희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.505-509
    • /
    • 2008
  • This paper studied the efficient noise prediction method for new apartment house near the road traffic noise. Three noise prediction software were compared by each prediction noise level using the simple model which is included the road, soundproofing wall and building. Two foreign national calculation models(RLS-90 and NMPB) were verified by comparison of measured sound level. Frequency of sound level was predicted by NMPB and compared by measured data. The sphere of noise source and facade reflection were proposed to accurate predict the road traffic noise in new apartment house.

  • PDF

대구지역 경부선 철도주변의 소음실태와 특성 (The Actual Conditions and Characteristics of Railroad Noise Level in Taegu Area in the Seoul-Pusan Line)

  • 민경섭;송희봉
    • 한국환경과학회지
    • /
    • 제6권1호
    • /
    • pp.9-16
    • /
    • 1997
  • We investigated and analysed the actual conditions and characteristics of railroad noise levels for 17 sites in the vicinity of the Seoul-Pusan Line. The results i,we summarized as follows : 11 Railroad noise level ranged to 64 ~ 74 $L_{eq}$ dB(A) at day time and ranged to 60 ~ 72 $L_{eq}$ dB(A) at night time. 21 Increased night noise level depend on the increase of trains passing at night time. 31 The major factor of Increased noise level in the vicinity of stations are using loudspeakers and stream whistle on trains. 4) Decreased effect of noise according to distance is able to be described quantitatively using regression equations of multiplicative model. $L_{eq}$=$78.59^{X-0.056}$, n =25, r=-0.994, s.e. =1.007 $P_{av}$ = $105.68X^{-0.073}$, n =25, r =-0.997, s.e. = 1.007 Also increased and decreased effect of noise according to floor in apartment Is able to be described quantitatively using regression equations of multiplicative model. $L_{eq}$ = $64.238X^{0.0567}$, n = 39, r = 0.787, s.e. = 1.004 $P_{av}$ =79.963X0.0524, n =39, r =0.689, s.e. = 1.056 5) Average noise level in high floor is over 70 $L_{eq}$ dB(A) at day and night time. so more detailed soundproofing countermeasured in high floors apartment is required.

  • PDF

배경잡음을 고려한 4배 가변 압축률을 갖는 ADPCM의 C6000 DSP 실시간 구현 (Implementation of Quad Variable Rates ADPCM Speech CODEC on C6000 DSP considering the Environmental Noise)

  • 김대성;한경호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.727-729
    • /
    • 2002
  • In this paper, we proposed quad variable rates ADPCM coding method and its implementation on C6000 DSP, which is modified from the standard ADPCM of ITU G.726 for speech quality improvement considering the environmental noise Four coding rates, 16Kbps, 24Kbps, 32Kbps and 40Kbps are used for speech window samples and the rate decision threshold is decided by the environmental noise level. The object of the proposed method is to reduce the coding rate while retaining the speech quality and the speech quality is considerably close to 40Kbps single rate coder with the coding rate close to 16Kbps single rate coder under the environmental noise. The environmental noise level affects the coding rate and the noise level is calculated per every speech window samples. At high noise level, more samples are coded at higher rates to enhance the quality, but at low noise level, only the big speech signals are coded at higher rates and more speech samples are coded at lower coding rates to reduce the coding rates. The influence of the noise on tile speech signal is considerably high for small signals and the small signal has the higher ZCR (zero crossing rate). The method is simulated in PC and to be implemented on C6000 floating point DSP board in real time operations.

  • PDF

레인지후드 덕트설치 조건에 따른 소음 및 풍량특성 연구 (A Study on the Performance of Noise Level and Airflow Amount of a Kitchen Hood by the Different Conditions of Airflow Path.)

  • 김일호;김윤재;이용준;이규동
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.11-14
    • /
    • 2007
  • Noise level and Airflow amount of a kitchen hood are affected by the conditions of airflow path. Thus this study is expected to be used as a basic reference in designing airflow path of apartment housing throughout analysing changes in noise level and airflow amount from the various conditions of airflow path. Noise level generated by the kitchen hood is estimated in a kitchen and a living room of two constructed apartment houses, and an experiment is conducted in an half anechoic chamber to analyze noise level and airflow amount by the different length, diameter and number of windings of a round shaped soft duct which is connected to the kitchen hood. The measured results in apartment houses show that the noise level in both apartments exceeds the NC standard greatly in living spaces. In apartment A, a regular apartment house, the noise level was $NC-65{\sim}75$, $NC-45{\sim}60$ and NC-70, NC-45 in the kitchen and living room with an operation of kitchen hood in 1 and 3 stages. In apartment B, an apartment complex, the noise level was NC-55 and NC-60 in the kitchen and living room with an operation of kitchen hood in 3 stages. In particular, there was an increase of noise level at 125Hz-band resulted from an amplification of sound, which requires adequate measures in noise reduction. The results measured in Half anechoic chamber show 99% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 100mm to ${\Phi}$ 125mm, 37% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 125mm to ${\Phi}$ 150mm, and 173% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ l00mm to ${\Phi}$ 150mm. The noise level was lower than the level measured in apartment housing about 20 in NC-value and 11.4 in dB(A)-value, which was interpreted as the effect of the load by the pressure condition at the rear end of the duct. Also, an amplification of sound in 125Hz-band influenced NC-value considerably, therefore effective measure is needed.

  • PDF

실험에 의한 직교류홴의 유량 및 소음 분석 (Experimental Study on the Design Parameter Effects on the Flow-rate and the Noise level in a Cross-flow Fan)

  • 안철오;류호선
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.41-48
    • /
    • 1998
  • This study was carried out to investigate the effect of design parameters on the volume flow-rate and the noise level and to finally find the optimal design variables. Eighteen cross-flow fans were designed by the method of orthogonal array, and the flow-rate and the noise level were measured. These data were analyzed by the neural network system. The effects of eight design variables(scroll exit angle, scroll arc length et al.) on the fan performance and the noise level were valuated and discussed. This experiment shows that the design solutions suggested by neural network system may increase its volume flow-rate and reduce noise simultaneously.

  • PDF

급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구 (An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom)

  • 이태강;고광필;최은석;김항;김선우
    • 한국소음진동공학회논문집
    • /
    • 제17권3호
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

항공기소음피해지역 설정 기준의 개선방안에 관한 고찰 : 학교를 중심으로 (A Study on the Amendment of Criteria for the Establishment of the Area Damaged by the Aircraft Noise : Criteria for School Classrooms)

  • 이준호;이기호
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.263-269
    • /
    • 2009
  • The purpose of this study is to propose an appropriate criterium for proper sound insulation service preventing school classrooms from aircraft noise. The guideline of noise level for school facility by Korean school health law is less than Leq 55 which is less stringent than that of other countries. It has been reported that many students are annoyed and disturbed for their works when they are exposed to the noise level over Leq 55. It is desirable to modify this guideline of indoor noise level for school classroom. The noise level of classroom of which windows are opened was measured relatively high in case the school is located at the outside of the official area damaged by aircraft noise. In order to minimize the influence of aircraft noise on the school classrooms in the vicinity of domestic airport, it is necessary to improve the present criteria of WECPNL 75 for the establishment of the area damaged by aircraft noise from WECPNL 70.

휴대용 음향기기 소음실태 및 소음도 평가 (The Survey for the Maximum Noise Level of Portable Audio Equipments and Its Assessment)

  • 이재원;구진회;박형규;이우석
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.3-8
    • /
    • 2013
  • Recently, the impact on hearing induced by using of portable audio equipment have been actively studied. In general, Because they turn the volume up with loud background noise, they may expose to louder noise. In this study, we investigated the maximum noise level of 20 the domestic potable audio equipment and estimated the impact of the hearing induced by portable audio equipment in according to exposure time. As a result, the use of portable audio equipment is assumed to be more three hours when the level of more than 50 % of volume is most likely to affect the hearing.