• 제목/요약/키워드: Noise Emission

검색결과 466건 처리시간 0.044초

Fourier Transform 분광기를 이용한 불안정한 분자의 방출분광학 (Emission Spectroscopy of Unstable Molecules using a Fourier Transform Spectrometer)

  • 이상국;김은식
    • 대한화학회지
    • /
    • 제37권4호
    • /
    • pp.371-377
    • /
    • 1993
  • 불안정한 분자의 방출분광학에 상요이 가능하도록 Fourier Transform 분광기를 변형시켰다. 불안정한 분자 라디칼 $CH_3S$는 고전압 직류 방전에 의한 supersonic expansion 속에서 jet 형태의 흐름으로 생성되었다. Supersonic expansion에 의하여 냉각된 라디칼의 형광 스펙트럼은 Fourier Transform UV/VIS 분광기에 의해서 얻어졌다. 스펙트럼의 signal/noise 비율은 증가하였으며, 분자 라디칼 $CH_3S$의 회전구조도 명확하게 볼 수 있었다.

  • PDF

회전기계 결함신호 진단을 위한 신호처리 기술 개발 (Signal Processing Technology for Rotating Machinery Fault Signal Diagnosis)

  • 최병근;안병현;김용휘;이종명;이정훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.331-337
    • /
    • 2013
  • Acoustic Emission technique is widely applied to develop the early fault detection system, and the problem about a signal processing method for AE signal is mainly focused on. In the signal processing method, envelope analysis is a useful method to evaluate the bearing problems and Wavelet transform is a powerful method to detect faults occurred on rotating machinery. However, exact method for AE signal is not developed yet. Therefore, in this paper two methods which are Hilbert transform and DET for feature extraction. In addition, we evaluate the classification performance with varying the parameter from 2 to 15 for feature selection DET, 0.01 to 1.0 for the RBF kernel function of SVR, and the proposed algorithm achieved 94% classification accuracy with the parameter of the RBF 0.08, 12 feature selection.

  • PDF

렌지 후드 용 개선된 시로코 홴의 소음특성 변화 (Noise Characteristics of Improved Sirocco Fan for Range Hood)

  • 김철호;최영석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.209-212
    • /
    • 2005
  • Recently, since structures have become extremely airtight with the development of high-rise apartments, mixed use residential and commercial buildings and offices, large capacity range hoods have become commonly implemented. However, the high noise level caused by this range hood system made of thin plate is the cause of increased complaints among users. In this study, the level of noise emitted from this type of range hood was measured by height at the user's location in the kitchen. It was confirmed that a great deal of noise was emitted in the downward direction of the hood. In order to minimize the noise emitted from this type of range hood, a new type of fan was manufactured. This was done by changing only the material and shape of the fan, since it was determined to be the primary source of noise emission. Then a comparison and evaluation were carried out regarding the noise characteristics between the new type of fan and the existing type of fan. As a result, it was confirmed that the noise from the new fan was reduced by more than 2 dB compared to the existing fan without noise interference at the discharge end.

  • PDF

음향방출법에 의한 발전용 밸브 누설평가 (The Evaluation of Internal Leak in Valve for Power Plant Using Acoustic Emission Method)

  • 이상국;이선기;이준신;이욱륜
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1733-1739
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

유발이음향 방사현상을 이용한 와우각 특성 해석 (Analysis of Cochlear Characteristics Using Evoked Otoacoustic Emission)

  • 이남호;최진영;조진호;이건일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.133-138
    • /
    • 1992
  • Evoked otoacoustic emission (e-OAE) signals are measured from adult and analyzed by computer. Stimulation and detection are repeated and averaged 1000 times for noise cancellation. e-OAE signals are analyzed on frequency domain and time domain. The frequency domain analysis reveals that frequency of stimulus and emission has lineal relationship in 50 dB input sound amplitude. This result altos the cross correlation method to be applied for latency calculation. As the stimulus frequency grows higher, the latency tine is shorter and the gain or emission signal becomes greater. We introduced two mathmatical functions to identify these latecy and gain. These results can be utilized for cochlear modeling.

  • PDF

고강도 구조용 내화강의 피로특성 및 음향방출신호의 시간-주파수 해석 (Fatigue Characteristics of High Strength Fire Resistance Steel for Frame Structure and Time-Frequency Analysis its Acoustic Emission Signal)

  • 김현수;남기우;강창룡
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.67-72
    • /
    • 2000
  • Demand for now nondestructive evaluation are growing to detect fatigue crack growth behavior to predict long term performance of materials and structure in aggressive environments especially when they are In non-visible area. Acoustic emission technique is well suited to these problems and has drawn a keen interests because of its dynamic detection ability, extreme sensitivity and location of growing defects. In this study, we analysed acoustic emission signals obtained in fatigue and tensile test of high strength fire resistance steel for frame structure with time-frequency analysis methods. The main frequency range is different in the noise and the fatigue crack propagation. It could be classified that it were also generated by composite fracture mechanics of cleavage, dimple, inclusion separation etc.

  • PDF

발전용 밸브누설 실시간 감시기술 연구 (Study on the Real-Time Leak Monitoring Technique for Power Plant Valves)

  • 이상국
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

음향방출법에 의한 원자력발전소 밸브내부 누설평가에 관한 연구 (A Study on the Evaluation of Internal Leak in Valve for Nuclear Power Plant Using Acoustic Emission Method)

  • 이상국;이선기;이준신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.284-289
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석 (Analysis of performance test results of CA-certified air cleaners from 2003 to 2015)

  • 김학준;홍기정;우창규;한방우;김용진
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Performance of All-Optical Multihop RoFSO Communication System over Gamma-Gamma Atmospheric Turbulence Channels

  • Zong, Kang;Zhu, Jiang
    • Journal of the Optical Society of Korea
    • /
    • 제19권5호
    • /
    • pp.437-443
    • /
    • 2015
  • In this paper, we analyze the performance of the all-optical multihop radio over a free space optical (RoFSO) communication system with amplify-and-forward (AF) relays under varying weather conditions. The proposed channel model considers the propagation loss, attenuation and atmospheric fading modeled by the Gamma-Gamma (GG) distribution. Both the amplified spontaneous emission (ASE) noise in the all-optical relays and the background noise projected onto receiver apertures have been considered in the analysis. The lower bound analytical expressions for the end-to-end bit error rate (BER) and outage probability are derived for the multihop system employing the all-optical relays with the full channel state information (CSI). Meanwhile, the exact results for BER and outage probability are obtained via Monte Carlo simulation. Results indicate the performance of the proposed system will be improved by the multihop transmission technology. For a fixed number of relays, the BER and outage probability will be increased with the deterioration of the weather conditions.