• 제목/요약/키워드: No-load condition

검색결과 363건 처리시간 0.03초

300kW급 가스엔진 열병합발전시스템 성능평가 및 실증 (The Experimental Evaluation and Verification of a 300kW Small Engine Cogeneration System)

  • 최재준;박화춘
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.332-337
    • /
    • 2009
  • The importance of the evaluation and verification of small-size cogeneration system has been emphasized because there is no KS-code related to the small-size cogeneration system. The evaluation method of small-size engine cogeneration system, regarding Japanese standard JIS B-8122 and international standard organization, ISO-8528, was applied to the system. The evaluation methods, start-test, rapid-load-up and rapid-load-down, etc. were executed at the system, and reasonable results were acquired. The electrical and thermal efficiencies were executed and analyzed at various load conditions. The NOx emission at various load condition was also measured. Finally, the gas engine cogeneration system was installed to a site for actual usage and it was continually operated during more than 6 months as the site condition.

  • PDF

고속 NO 분석기를 이용한 Sl 엔진에서의 사이클 변동에 따른 NO 배출에 관한 분석 (Analysis on Cycle-by-Cycle NO Emissions from an Sl Engine with Fast HO Analyser)

  • 성정민;김현우;이경환
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.73-79
    • /
    • 2002
  • The NO emissions at the exhaust manifo1d were investigated with a fast NO analyzer to investigate the cycle-by-cycle variations on NO emissions level and the dependence of NO emissions on combustion. The measurement was performed with a part load condition with respect to the mixture ratios and the changes in loads at 1800rpm. The averaged values were obtained during 200 cycles. We found that there is characteristic pattern in 70 emissions from exhaust port and it was possible to set a representative value with the data sampled during specific period. As the load increased, the characteristics of NO emissions were more dependent on combustion pressures. It was also analyzed that the correlation between combustion pressures and NO emissions for different equivalence ratios tends to increase as the mixture goes leaner, Furthermore, this correlation for the lean mixture near the lean limit seemed to be kept.

고온화재조건 콘크리트 라이닝의 하중비에 따른 폭렬영향성 및 화재손상특성에 관한 실험적 연구 (An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire)

  • 김형준;김흥열;박경훈;안찬솔;권기혁
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.145-151
    • /
    • 2010
  • 터널의 화재는 초동진압에 실패할 경우 터널의 내부는 상당한 화재하중이 존재하고, 제연설비의 영향으로 화재전파속도가 빨라 단시간 내에 화재의 확산과 함께 고온으로 발전하여 터널 구조체 및 인명에 대한 피해를 증대시킨다. 이에 본 연구에서는 초기 가장 급격한 온도상승이 발생하는 시나리오인 MHC(Modified Hydrocarbon) 화재곡선을 대상으로 하중비를 0, 20, 40, 60, 70%를 조정한 화재실험을 수행하여 하중재하에 의한 콘크리트 폭렬영향성 및 화재손상범위에 대한 열적특성을 규명하고자 하였다. 실험체는 EFNARC에서 규정한 소규모 실물실험체 형상조건을 준용하였으며, 배합강도는 일반강도인 24MPa로 실험제반조건을 선정하였다. 실험수행결과 비재하조건의 라이닝의 경우 16mm의 폭렬이 발생하였으나 하중비 20%와 40%에서는 폭렬이 발생하지 않았다. 재하 하중비를 증가시킨 60%의 경우 24mm의 폭렬이 발생하였으며, 70% 재하조건의 경우 가열시작 10분 이후에 파괴되었다.

Design of a Fuel Cell Power Conditioning System for Online Diagnosis and Load Leveling

  • Nguyen, Thanh-Tuan;Doan, Van-Tuan;Choi, Woojin
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.695-703
    • /
    • 2016
  • A fuel cell power conditioning system for online diagnosis and load leveling under the condition of varying load is developed in this study. The proposed system comprises a unidirectional boost converter and a bidirectional buck-boost converter with a battery. The system operates in two different modes. In normal mode, the bidirectional converter is utilized for load leveling; in diagnostic mode, it is utilized to control load voltage while the boost converter generates perturbation current to implement the online diagnosis function through in-situ electrochemical impedance spectroscopy (EIS). The proposed method can perform EIS for a fuel cell under varying-load conditions with no influence on the load. The validity and feasibility of the proposed system are verified by experiments, and the design procedure of the proposed system is detailed.

정적 부하의 비대칭적 적용에 따른 등 근육의 근전도 분석 (An Electromyographic Analysis of Back muscle Activity when Subjects are Lifting Static Loads in One Hand)

  • 김태영;박은영;이응상
    • 한국전문물리치료학회지
    • /
    • 제4권1호
    • /
    • pp.78-86
    • /
    • 1997
  • Back muscles play an important role in protecting the spine. Epidemiological studies have shown that loads imposed on the human spine during daily living play a significant role in the onset of low back pain. No previous study has attempted to correlate the response of the trunk musculature with the type of external load. The purpose of this study was to use surface electromyography (EMG) to quantify the relative demands placed on the back muscles while lifting loads in one hand. Forty asymptomatic, twenty year-old subjects stood while lifting loads of 10% of body weight(BW) unilaterally. All EMG data were normalized to a percentage of the EMG voltage produced during no-load standing(%EMG). Our major analysis involved a paired t-test for repeated measures. Of particular note was the fact that the ipsilateral 10% of BW condition produced statistically less % EMG change than did the contralateral 10% of the condition.

  • PDF

윤하중조건에서의 프리캐스트 콘크리트 바닥판 피로특성 (Fatigue Characteristics of Precast Concrete Bridge Decks under Wheel Load Condition)

  • 주봉철;박흥석;김영진;송재준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.394-397
    • /
    • 2006
  • For checking fatigue safety and endurance of precast concrete deck and loop joint system in the steel plate girder composite bridge, the test composite bridge model was made for the fatigue experiment by the wheel load machine. The fatigue tests of 1,000,000 cycles were implemented according to wheel load condition of DB24 rear axle of Korea Highway Design Code. From the test results, the loop joint system for the precast deck has a sufficient flexural capacity. Although a little lower longitudinal continuity capacity is evaluated than general sound cast-in-place RC bridge deck, there is no problem about the safety. The overall fatigue level of safety defined by the code is satisfied.

  • PDF

연료전지의 진단 및 부하 평준화를 위한 다중 컨버터 시스템의 설계 (Design of the Multi-converter System for Fuel Cell Diagnosis and Load Leveling)

  • 응웬탄두안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.11-12
    • /
    • 2013
  • In this research, a novel multi-converter system for the fuel cell diagnostics and the load leveling function under varying load condition is proposed. The proposed system is composed of two converters and operates in two different modes. In the normal mode operation the additional bidirectional converter is used for the load leveling and in the diagnostic mode it is used for implementing integral diagnostics by way of electrochemical impedance spectroscopy (EIS). The proposed method can perform the EIS for fuel cell under varying load conditions with no influence to the load. The validity and feasibility of the proposed system is verified by the experiments and the design procedure of the proposed system is detailed.

  • PDF

Does Strategy of Downward Stepping Stair Due to Load of Additional Weight Affect Lower Limb's Kinetic Mechanism?

  • Ryew, Checheong;Yoo, Taeseok;Hyun, Seunghyun
    • International journal of advanced smart convergence
    • /
    • 제9권4호
    • /
    • pp.26-33
    • /
    • 2020
  • This study measured the downward stepping movement relative to weight change (no load, and 10%, 20%, 30% of body weight respectively of adult male (n=10) from standardized stair (rise of 0.3 m, tread of 0.29 m, width of 1 m). The 3-dimensional cinematography and ground reaction force were also utilized for analysis of leg stiffness: Peak vertical force, change in stance phase leg length, Torque of whole body, kinematic variables. The strategy heightened the leg stiffness and standardized vertical ground reaction force relative to the added weights (p<.01). Torque showed rather larger rotational force in case of no load, but less in 10% of body weight (p<.05). Similarly angle of hip joint showed most extended in no-load, but most flexed in 10% of body weight (p<.05). Inclined angle of body trunk showed largest range in posterior direction in no-load, but in vertical line nearly relative to added weights (p<.001). Thus the result of the study proved that downward stepping strategy altered from height of 30 cm, regardless of added weight, did not affect velocity and length of lower leg. But added weight contributed to more vertical impulse force and increase of rigidity of whole body than forward rotational torque under condition of altered stepping strategy. In future study, the experimental on effect of weight change and alteration of downward stepping strategy using ankle joint may provide helpful information for development of enhanced program of prevention and rehabilitation on motor performance and injury.

Three Buffer 맥동관 냉동기에 관한 실험적 연구 (An Experimental Study of a Therr Buffer Pulse Tube Refrigerator)

  • 박성재;고득용;김효봉;신완순
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF

Performance of Rock-socketed Drilled Shafts in Deep Soft Clay Deposits

  • Kim, Myung-Hak
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.409-429
    • /
    • 2006
  • In designing rock-socketed drilled shaft, bearing capacity evaluation is very important because the maximum values of base and side resistance are not generally mobilized at the same value of displacement, FHWA and AASHTO code suggest different ultimate bearing capacity formular according to rock type and shaft settlement. In domestic code suggest base resistance and side resistance can be added on condition that after confirming the result of field load test with axial load transfer test. This paper shows that static load test and hi-directional load test result analysis of deep rock-socketed drilled shaft in three different sites. Load-settlement curve, t-z, and q-w curve in rock-socketed part were calculated and compared. t-z curve in weathered and soft rock showed no deflection softening behavior in pretty large strain (about 2-3% of diameter). Ultimate resistance could be the summation of side resistance and base resistance in rock-socketed drilled shaft in domestic sites.

  • PDF