• Title/Summary/Keyword: No-Load Test

Search Result 691, Processing Time 0.029 seconds

Development Trends of Tidal Current Energy and Its Test Bed (조류에너지의 이용기술)

  • Yang, Changjo;Hoang, T.G.
    • Vacuum Magazine
    • /
    • v.3 no.2
    • /
    • pp.11-16
    • /
    • 2016
  • Tidal current energy is the most interesting renewable resources that have been less harnessed. Korea has globally outstanding tidal current energy resources and it is highly needed to develop a tidal current energy conversion system. It is reported that the total amount of available tidal current energy is approximately 6GW in Korea. A good tidal site candidate is required a large amount of fast moving water, bathymetry and seabed properties, no conflicts with other users and is close to a load and grid interconnection. In this review, we summarized the results of R&D projects regarding tidal current resources, utilization projects and demonstration test bed.

A Study on the Engine Performance and Combustion Characteristics of Fish Oil in a Diesel Engine (디젤기관에서의 어유의 연소특성과 기관성능에 관한 연구)

  • 서정주;왕우경;안수길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.3
    • /
    • pp.85-93
    • /
    • 1994
  • The engine performance and combustion characteristics of diesel oil and fish oil blended with diesel oils were investigated at various blending rate of fish oil in a diesel engine. The maximum pressure showed no significant difference among test fuels at low load, but it was higher as the blending rate of fish oil increases at high load. Increasing the blending rate of fish oil, the rate of heat release and burned fraction were higher than those of diesel oil. The ignition delay became longer than that of diesel oil as the blending rate of fish oil increases, and its differences were larger at different loads. The combustion duration and density of smoke were shorter and lower as the blending rate of fish oil increases. The rate of fuel consumption showed no significant difference between diesel oil and fish blended with diesel oils.

  • PDF

비아50 구조 구성품 정적강도 시험

  • Kang, Wang-Gu;Kim, Dong-Min;Lee, Jin-Woo;Yeom, Chan-Hong
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • Tail-wing, gondola and thrust motor mount(EMS) were built by carbon/glass fiber composites. Structural strength & stiffness was verified by specimen tests. Static strength tests for each structural components were conducted separately. Boundary conditions are specially designed for each components to simulate exact joint conditions. Tests shows no detriment deformation at 100% DLL and no failure at 150% DLL.

  • PDF

High Temperature Deformation Behavior of Ti-Al Intermetallic Compound - Microstructure Effect (TiAl 금속간 화합물의 미세조직에 따른 고온변형특성)

  • 하태권;정재영;이광석;장영원
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.295-298
    • /
    • 2003
  • High temperature deformation behavior of a Ti-Al intermetallic compound has been investigated. Specimens with a near gamma and a lamella structures were obtained by performing heat treatment at 1200 and 1330$^{\circ}C$, respectively, for 24 hr and stabilized at 900$^{\circ}C$ for 4 hr followed by air cooling. A series of load relaxation tests has been conducted on these samples at temperatures ranging from 850 to 950$^{\circ}C$ to construct flow curves in the strain rate range from 10$\^$-6//s to 10$\^$-3//s. Strain hardening was observed even at the temperature of 950$^{\circ}C$ in both the near gamma and the lamella structures. Further aging treatment for 12 hr at test temperatures has found to cause no softening in both microstructures.

  • PDF

The Seismic Performance for Concrete-filled Steel Piers (콘크리트 충전 강교각의 내진 성능)

  • 정지만;장승필;인성빈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.189-196
    • /
    • 2002
  • The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

  • PDF

A study on Analysis Technique of Design Parameters for Brushless DC motor (Brushless DC motor의 설계 Parameter 분석 기법에 관한 연구)

  • Maeng, Kyung-Ho;Park, Chang-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.6-8
    • /
    • 2004
  • Recently, it is increasing to use more Brushless DC Motor with high energy density permanent magnet and semiconductor control unit for complementing the mechanical defect of Brushed DC Motors. For designing of BLDC Motors are required complex parameters like as rated characteristic, Geometries, B-H curve of magnet and steel materials, winding factor, etc. Moreover, design and manufacturing are difficult because of additional control circuits. Generally, Design parameters are gotten by analysis of Motor which is used. And the design parameters are used to design a new motor. But getting the design parameters through the eyes and experience is limited and it takes a long time. In this paper a method is proposed to efficiently analyze motor design parameters through the No load and Load Test, Back EMF Test, Simulation Analysis and Patent Analysis Method for existing BLDC Motor for a cooling Fan in Vehicle.

  • PDF

Test of a High Temperature Superconducting Power Transformer (고온초전도변압기 특성시험)

  • Lee, H.J.;Cha, G.S.;Kim, W.S.;Han, S.Y.;Ryu, K.W.;Choi, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.33-35
    • /
    • 1999
  • This paper describes the test results of the single phase 3kVA high temperature superconducting power trans-former. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used in total. Among them two double pancake windings are connected in series for high voltage winding and two double pancake windings are connected in parallel for low voltage winding. The rated voltages of each winding are 220/110 V. Fundamental characteristics are obtained through short circuit and no load tests. The over load capability and characteristics are investigated.

  • PDF

Hysteretic Behavoir of Flat Plate System Using Rebar Type Shear Reinforcement (철근형 전단보강근을 사용한 플랫 플레이트 시스템의 이력 거동)

  • Lee, Hyun-Ho;Chun, Young-Soo;Kim, Jin-Soo;Lee, Do-Bum;Kim, Ook-Jong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.55-58
    • /
    • 2005
  • From the development of residential flat plate system, continuously bended shear reinforcements were applied in the joint performance test. The testing parameters are shear reinforcement types, which are no reinforcement, studrail reinforcement, and rebar type reinforcement. To verify the lateral resisting capacity, cyclic load is applied in the constant vertical load condition. From the test results, the resisting capacity of developed shear reinforcement system has a good performance behavior in the story drift ratio.

  • PDF

Seismic behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 1: Experimental study

  • Zhu, Y.;Su, R.K.L.;Zhou, F.L.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.2
    • /
    • pp.149-172
    • /
    • 2007
  • An experimental study of five full-scale coupling beam specimens has been conducted to investigate the seismic behavior of strengthened RC coupling beams by bolted side steel plates using a reversed cyclic loading procedure. The strengthened coupling beams are fabricated with different plate thicknesses and shear connector arrangements to study their respective effects on load-carrying capacity, strength retention, stiffness degradation, deformation capacity, and energy dissipation ability. The study revealed that putting shear connectors along the span of coupling beams produces no significant improvement to the structural performance of the strengthened beams. Translational and rotational partial interactions of the shear connectors that would weaken the load-carrying capacity of the steel plates were observed and measured. The hierarchy of failure of concrete, steel plates, and shear connectors was identified. Furthermore, detailed effects of plate buckling and various arrangements of shear connectors on the post-peak behavior of the strengthened beams are discussed.

The Study on a Dynamic Analysis of Permanent Magnet Generator considering Overhang Effect (오버행을 고려한 영구자석 동기 발전기의 동특성 해석 연구)

  • Kim, Ki-Chan;Lee, Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.58-62
    • /
    • 2006
  • The purpose of this paper is characteristic analysis of permanent magnet generator (PMG) for automatic voltage regulator (AVR)power of brush less synchronous generator. However, this PMG has a spoke type permanent magnet rotor with large overhang for high power density, characteristic analysis considering concentration effect of air-gap flux density due to the overhang should be performed. 30 transient finite element method (FEM)analysis is good solution for overhang parameter, but this method needs too much calculation time. In this paper, we examined the overhang effects based on overhang length and material of rotor core by using 20 and 30 static FEM analysis, and proposed 20 dynamic FEA model considering overhang parameter which gives good and rapid results. The proposed method is verified by the test results of no load, load and short circuit test.

  • PDF