• Title/Summary/Keyword: No

Search Result 126,461, Processing Time 0.088 seconds

Effect of Propene($C_3H_6$) ON NO-$NO_2$ Conversion Process in a Pulsed Corona Discharge (펄스코로나 방전에서 프로핀($C_3H_6$)이 NO-$NO_2$ 변환에 미치는 영향에 관한 연구)

  • 박광서;전배혁;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.67-77
    • /
    • 2000
  • Investigated was the effect of propene(C3H6) on the NO-NO2 conversion in dry exhaust gases from lean burn engine using a pulsed corona discharge. A kinetic model was developed to characterize the plasma chemistry in simulated exhausts containing propene. The model uses ELENDIF program to solve Boltzmann equation for electron energy distribution function, and CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement for NO and NO2 concentrations with the experimental data, and predicts the formation of byproducts such as CH2O, CH3HCO, CO AND CH3NO2 Propene enhances the NOx conversion enormously at lower energy density and the NOx conversion increases with the increase of initial propene and oxygen concentration, and temperature.

  • PDF

Method for NoC Bottleneck Relaxation Using Proxy (프록시를 이용한 NoC의 병목현상 해소 방법)

  • Kim, Kyu-Chull;Kwon, Tai-Hwan
    • The KIPS Transactions:PartA
    • /
    • v.18A no.1
    • /
    • pp.25-32
    • /
    • 2011
  • NoC is actively being studied recently in order to overcome the limitations of shared-bus architecture. We proposed an NoC architecture which employs a buffer that plays a similar role of a proxy server in a computer network to enhance the communication efficiency of NoC architecture. In the proposed NoC architecture, whenever the master has a difficulty in communicating with the slave directly, the master communicates with the proxy server which is able to communicate with the slave on behalf of the master. With the proposed scheme in NoC, we can increase the speed and the bandwidth of communication channel. The experimental results showed that overall communication efficiency was significantly improved by sending the packets to the proxy server rather than holding them in the switch buffer.

Image Observation of NO Particles Using ICCD Camera (ICCD Camera를 이용한 NO입자의 Image관측)

  • 전용우;하장호;박원주;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.98-103
    • /
    • 2001
  • In this parer, the removal rate of NO in a reactor is rreasured first using nonthermal plasma generated from a wire-cylinder type reactor, then the discharge image and horizontal signal strength and vertical signal strength of NO particles is observed using ICCD(Intensified Charged Coupled Device) carrera It was fOlmd that NO rerroval rate was iflLTeased with NO concentration c1ecreasing, and that honzontal signal strength and vertical signal strength were also increased with NO concentration decreasing. Especially, this research is a1!Tffl at clarifying the discharge mechanism of NO particles by observing the images of AC discharge wnen the nonthermal plasma generated by an discharge was used.

  • PDF

The Methods Calculating the Reduction Efficiency of Nitrogen Oxide for the Facilities Including the Low NOx Burners (저녹스 버너 설치 시설의 질소산화물 저감 효율 산정 방법)

  • Lee, Ki Yong;Talukder, Niladri
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.295-296
    • /
    • 2015
  • We presented the methods calculating the reduction efficiency of nitrogen oxide for the low $NO_x$ burner as the pollution prevention facilities. The standard $NO_x$ concentration was used on the emission factor of LNG, $3.7g/m^3$. The $NO_x$ reduction efficiency based on the $NO_x$ concentration was presented and the relationships between the $NO_x$ concentration and the emission factor or the specific heat emission factor were derived. These results could be accurately reflected on calculating the amount of the nitrogen oxide emissions. In addition, according to the arrangement of the low $NO_x$ burners the methods of applying their $NO_x$ reduction efficiency were proposed. The $NO_x$ reduction efficiency for the facilities consisting of the low $NO_x$ burners and the non-low $NO_x$ burners could be estimated with information about the reduction efficiency of each low $NO_x$ burners, the fuel consumption rate, and the heating value of fuel.

  • PDF

Numerical analysis of NOx formation characteristics in CH$_{4}$-air jet diffusion flame (CH$_{4}$-공기 분류 확산화염의 NOx 생성특성에 관한 수치해석)

  • O, Chang-Bo;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.193-204
    • /
    • 1998
  • Numerical analysis was performed with multicomponent transport properties and detailed reaction mechanisms for axisymmetric 2-D CH$_{4}$ jet diffusion flame. Calculations were carried out twice with the $C_{2}$-Thermal Mechanism including $C_{2}$ and thermal NO reactions and the $C_{2}$-Full Mechanism including prompt NO reactions in addition to the above $C_{2}$-Thermal NO mechanism. The results show that the flame structures such as flame temperature, major and minor species concentration are indifferent to respective mechanisms. The production path of Thermal NO is dominant comparing with that of Prompt NO in total NO production of pure CH$_{4}$ jet diffusion flame. This is because thermal NO mechanism mainly contributes to positive formation of NO in the whole flame region, but Prompt NO mechanism contributes to negative formation in the fuel rich region. In addition, 0$_{2}$ penetration near the nozzle outlet affects the flame structures, especially N0$_{2}$ formation characteristics.

Core network maintenance by NO.7 protocol analyzing (Core Network 유지 보수를 위한 NO.7 Protocol 감시 방안)

  • Yoo Jun-Mo;Kim Yun-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.1
    • /
    • pp.49-60
    • /
    • 2005
  • The Back Bone of gearing portion between Core Network System which is used in wire and wireless system is No.7 Protocol. ISUP( ISDN User Part), INAP handling in Intelligent Network and MAP gearing method for linking each Network Element System in mobile network have use of No.7 signaling. Therefore, it is require for system to detect the problem - operating problem occurs in Core Network which use No.7 signaling or the existing problem that is not recognized - in shortest time. This paper study out analyzing and measuring system for No.7 protocol and analyzing out system whether out of order or not. It can abstract No.7 Signaling Message and analyze system performance and report it. This system is connected in system No.7 HW Module which is in charge of No.7 Signaling. It is not offer Emulator function and Simulation function for any scenario but offer monitoring No.7 signaling. This system perform the function about No.7 MTP, ISUP, INAP and MAP and is offered several wire and wireless network Operator. It can detect and correct SW system, HW system and operating system problem. From now on, this system may offer the function about A-interface which is gearing between BSC and MSC, so it will perform to analyze generally and prompt effective operating for Core Network system.

Phosphorus Removal by DPAOs (Denitrifying Phosphorus Accumulating Organisms) in Aerobic Condition (호기 조건에서 DPAOs (Denitrifying Phosphorus Accumulation Organisms)에 의한 인 제거)

  • Jeong, No-Sung;Park, Young-Seek;Kim, Dong-Seog
    • KSBB Journal
    • /
    • v.25 no.1
    • /
    • pp.62-66
    • /
    • 2010
  • This study was carried out to get phosphorus uptake rate in aerobic condition with nitrate and nitrite. Nitrate and nitrite inhibited phosphorus accumulating organisms' (PAOs') luxury uptake in aerobic condition. Nitrite awfully decreased the phosphorus uptake rate in aerobic condition. At the influent of 10 mg ${NO_3}^-$-NL, the phosphorus uptake was decreased to 52% comparing that at no influent of nitrate. And at the influent of 10 mg ${NO_2}^-$-NL, the phosphorus uptake was decreased to 28% comparing that at no influent of nitrite. At the influent of 20 mg ${NO_3}^-$-NL, nitrite and nitrate were co-existed and the phosphorus uptake rate was decreased to 16% comparing that at no influent of nitrite and nitrate. Also, the denitrification was occurred by denitrifying glycogen accumulating organisms (DGAOs)/denitrifying phosphorus accumulating organisms (OPAOs) in spite of aerobic condition, and the phosphorus uptake rate was increased by the decrease of influent nitrate concentration at the aerobic condition. The inflection point in the phosphorus uptake rate was shown at the nitrite concentration of 1.5~2 mg/L.

Comparison of the cultivation performance between Korean (Sugwawon No. 301) and Chinese strains (Huangguan No. 1) of kelp Saccharina japonica in an aquaculture farm in Korea

  • Hwang, Eun Kyoung;Liu, Fuli;Lee, Ki Hyun;Ha, Dong Su;Park, Chan Sun
    • ALGAE
    • /
    • v.33 no.1
    • /
    • pp.101-108
    • /
    • 2018
  • Saccharina japonica was introduced to both Korea and China from Hokkaido, Japan, and it has become an economically important species in both nations. After a long period of cultivation, several varieties of S. japonica have been developed in Korea and China. In this study, we conducted aquacultural research on the persistence of thalli from two kelp cultivars, one from China (Huangguan No. 1) and one from Korea (Sugwawon No. 301), between December 2015 and November 2016 in Haenam, Korea. The maximum length was $247.8{\pm}13.0$ and $227.5{\pm}42.0cm$, respectively, which were significantly longer in Sugwawon No. 301 than in Huangguan No. 1. The maximum width was $29.9{\pm}5.4$ and $23.2{\pm}1.9cm$, respectively, which were significantly wider in Huangguan No. 1 than in Sugwawon No. 301. The mean biomass obtained from the culture ropes was for Sugwawon No. 301 was $3.5{\pm}0.3kg\;wet\;wt\;m^{-1}$ and for while Huangguan No. 1 was $3.1{\pm}1.0kg\;wet\;wt\;m^{-1}$ of culture rope. After August, the persistence of the thalli of Sugwawon No. 301 was two months longer than that of Huangguan No. 1. We found that the Sugwawon No. 301 performed as well as the Huangguan No. 1 in Korean waters possibly due to increased flexibility as a result of the different cell arrangements of the two cultivars. Overall, the use of the Sugwawon No. 301 cultivar rather than the Huangguan No. 1 cultivar of S. japonica appears the best alternative to help to ensure a stable year round algal feed supply for the Korean abalone industry.

Determination of an LNT Regeneration Condition Based on a NOx Storage Fraction in a 2.2L Direct Injection Diesel Engine (2.2L 디젤 엔진에서 NOx 흡장률 기반 LNT 재생 조건 결정)

  • Chun, Bongsu;Lee, Jungwoo;Han, Manbae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.345-351
    • /
    • 2016
  • This study was carried out to determine an optimal lean $NO_x$ trap (LNT) regeneration condition based on a $NO_x$ storage fraction. The LNT regeneration was performed by an in-cylinder post fuel injection method. A $NO_x$ storage fraction is defined by the ratio of current cumulated $NO_x$ amount in the LNT to the $NO_x$ storage capacity: 0 means empty and 1 fully loaded. In this study five engine operating conditions were chosen to represent the New European Driving Cycle. With various $NO_x$ storage fractions each engine operating condition, the LNT regeneration was executed and then $NO_x$ conversion efficiency, additional fuel consumption, CO and THC slip, peak catalyst temperature were measured. The results showed that there exist an optimal condition to regenerate the LNT, eg. 1500 rpm 6 bar BMEP with below 0.7 $NO_x$ storage fraction in this experimental constraint.

Analysis of Relationship between O3, NO, and NO2 in Riyadh, Saudi Arabia

  • Shareef, Mohammed Mujtaba;Husain, Tahir;Alharbi, Bader
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.17-29
    • /
    • 2018
  • For the first time in the city of Riyadh, the formation of $O_3$ and its relationship with NO and $NO_2$ ($NO_x$) was investigated. Throughout the summer $O_3$, NO, and $NO_2$ were collected from three locations: residential, industrial, and rural areas. During the sampling period $O_3$ concentrations exceeded 1-hour local standards a few times yet remained consistent with the standards most of the time. The $O_3$ concentrations were observed highest in the rural location and lowest in the industrial area. The diurnal variation of NO followed a double peak: one in the morning and the other in the evening, representing the traffic pattern. Early morning NO peaks were observed in the rural location, which were attributed to the movement of NO from other locations. The $O_3$ concentrations depicted typical pattern, increasing after sunrise and reaching its maximum during midday. The highest $O_3$ concentrations were observed in the rural location followed by the residential and industrial. $NO_2$ photolysis rates were 3-4 times higher compared to other similar investigations, potentially due to intense solar radiation. A strong negative correlation was observed between $NO_x$ and $O_3$ values in the industrial location indicating photochemical activities around the industrial area were higher, likely due to additional $NO_x$ emissions from industries. Regression analysis of $NO_x$ and OX ($O_3+NO_2$) indicated that in residential and industrial locations at nighttime there were large $NO_x$ independent regional contributions which is attributed to VOCs. The Weekend Effect was observed in the city potentially due to the production of the OH radical and subsequent reactions with VOCs implying that the area is VOC-sensitive.