• Title/Summary/Keyword: Nitrogen dioxide($NO_2$)

Search Result 233, Processing Time 0.023 seconds

Estimation of surface nitrogen dioxide mixing ratio in Seoul using the OMI satellite data (OMI 위성자료를 활용한 서울 지표 이산화질소 혼합비 추정 연구)

  • Kim, Daewon;Hong, Hyunkee;Choi, Wonei;Park, Junsung;Yang, Jiwon;Ryu, Jaeyong;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.135-147
    • /
    • 2017
  • We, for the first time, estimated daily and monthly surface nitrogen dioxide ($NO_2$) volume mixing ratio (VMR) using three regression models with $NO_2$ tropospheric vertical column density (OMIT-rop $NO_2$ VCD) data obtained from Ozone Monitoring Instrument (OMI) in Seoul in South Korea at OMI overpass time (13:45 local time). First linear regression model (M1) is a linear regression equation between OMI-Trop $NO_2$ VCD and in situ $NO_2$ VMR, whereas second linear regression model (M2) incorporates boundary layer height (BLH), temperature, and pressure obtained from Atmospheric Infrared Sounder (AIRS) and OMI-Trop $NO_2$ VCD. Last models (M3M & M3D) are a multiple linear regression equations which include OMI-Trop $NO_2$ VCD, BLH and various meteorological data. In this study, we determined three types of regression models for the training period between 2009 and 2011, and the performance of those regression models was evaluated via comparison with the surface $NO_2$ VMR data obtained from in situ measurements (in situ $NO_2$ VMR) in 2012. The monthly mean surface $NO_2$ VMRs estimated by M3M showed good agreements with those of in situ measurements(avg. R = 0.77). In terms of the daily (13:45LT) $NO_2$ estimation, the highest correlations were found between the daily surface $NO_2$ VMRs estimated by M3D and in-situ $NO_2$ VMRs (avg. R = 0.55). The estimated surface $NO_2$ VMRs by three modelstend to be underestimated. We also discussed the performance of these empirical modelsfor surface $NO_2$ VMR estimation with respect to otherstatistical data such asroot mean square error (RMSE), mean bias, mean absolute error (MAE), and percent difference. This present study shows a possibility of estimating surface $NO_2$ VMR using the satellite measurement.

Analysis of PM10 Concentration using Auto-Regressive Error Model at Pyeongtaek City in Korea (자기회귀오차모형을 이용한 평택시 PM10 농도 분석)

  • Lee, Hoon-Ja
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.358-366
    • /
    • 2011
  • The purpose of this study was to analyze the monthly and seasonal PM10 data using the Autoregressive Error (ARE) model at the southern part of the Gyeonggi-Do, Pyeongtaek monitoring site in Korea. In the ARE model, six meteorological variables and four pollution variables are used as the explanatory variables. The six meteorological variables are daily maximum temperature, wind speed, amount of cloud, relative humidity, rainfall, and global radiation. The four air pollution variables are sulfur dioxide ($SO_2$), nitrogen dioxide ($NO_2$), carbon monoxide (CO), and ozone ($O_3$). The result shows that monthly ARE models explained about 17~49% of the PM10 concentration. However, the ARE model could be improved if we add the more explanatory variables in the model.

Retrieval of Nitrogen Dioxide Column Density from Ground-based Pandora Measurement using the Differential Optical Absorption Spectroscopy Method (차등흡수분광기술을 이용한 지상기반 Pandora 관측으로부터의 대기 중 이산화질소 칼럼농도 산출)

  • Yang, Jiwon;Hong, Hyunkee;Choi, Wonei;Park, Junsung;Kim, Daewon;Kang, Hyeongwoo;Lee, Hanlim;Kim, Joon
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_1
    • /
    • pp.981-992
    • /
    • 2017
  • We, for the first time, retrieved tropospheric nitrogen dioxide ($Trop.NO_2$) vertical column density (VCD) from ground-based instrument, Pandora, using the optical density fitting based on Differential Optical Absorption Spectroscopy (DOAS)in Seoul for the period from May 2014 to December 2014. The $Trop.NO_2$ VCDs retrieved from Pandora were compared with those obtained from Ozone Monitoring Instrument (OMI). A correlation coefficient (R) between those retrieved from Pandora and those obtained from OMI is 0.55. To compare with surface $NO_2$ VMRs obtained from in-situ, Trop. $NO_2$ VCDs retrieved from Pandora and those obtained from OMI are converted into $NO_2$ VMRs in boundary layer (BLH $NO_2$ VMRs) using data measured from Atmospheric Infrared Sounder (AIRS). Surface $NO_2$ VMRs obtained from in-situ range from 5.5 ppbv to 61.5 ppbv. BLH $NO_2$ VMRs retrieved from Pandora and OMI range from 2.1 ppbv to 44.2 ppbv and from 0.9 ppbv to 11.6 ppbv, respectively. The range of BLH $NO_2$ VMRs retrieved from OMI is narrower than that of BLH $NO_2$ VMRs retrieved from Pandora and surface $NO_2$ VMRs obtained from in-situ. There is a batter correlation between surface $NO_2$ VMRs obtained from in-situ and BLH $NO_2$ VMRs retrieved from Pandora (R= 0.50)than the correlation between surface $NO_2$ VMRs obtained from in-situ and BLH $NO_2$ VMRs retrieved from OMI (R = 0.36). This poor correlation is thought to be due to the lower near-surface sensitivity of the satellite-based instrument (OMI) than Pandora, the ground-based instrument.

Long-term Trend Analysis of NOx and SOx over in East Asia Using OMI Satellite Data and National Emission Inventories (2005-2015) (OMI 위성 자료와 국가 배출량 자료를 활용한 동아시아의 NOx, SOx 변화 장기 분석(2005-2015))

  • Seo, Jeonghyeon;Yoon, Jongmin;Choo, Gyo-Hwang;Kim, Deok-rae;Lee, Dong-Won
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.121-137
    • /
    • 2020
  • Data from the Ozone Monitoring Instrument (OMI) satellite and national emission inventories were used in this study to analyze air quality in East Asia and estimate the impact of domestic and foreign emissions on South Korea's air quality, based on which future emissions were predicted. The concentration trends of nitrogen dioxide (NO2) and sulfur dioxide (SO2) in East Asia from 2005 to 2015 showed that both substances were highest in North East China (NEC), followed by South East China (SEC) and Seoul Metropolitan Area (SMA). The average SO2 concentration was 1.63 times higher in NEC than in SMA. Analysis on the ratios of NO2/SO2 and NOx/SOx provides an indirect picture of the effect of transboundary air pollutants on atmospheric composition in Korea. The concentration ratio of NO2/SO2 in all study areas peaked in 2013 and SMA's emission ratio of NOx/SOx increased in 2015 by over 22% from 2013. Despite the reduction in domestic emissions, the concentration-to-emission ratios (NO2/NOx, SO2/SOx) rose gradually, which implies that other factors besides domestic emissions (e.g., foreign sources, lifetime, etc.) influence air quality in SMA. We estimated future emissions of NOx and SOx in SMA to be 296.2 and 39.0 ktons in 2025 and 284.4 and 33.8 ktons in 2035, respectively. Application of the inter-comparison techniques of this study to the data from the Geostationary Environment Monitoring Instrument (GEMS) is expected to provide concrete information which can be used to improve national emission inventories and figure out factors and sources that affect domestic air quality.

Perceived Air Quality Assessment of Occupants According to Indoor Air Quality (실내공기질에 따른 재실자의 인식성 공기질 평가)

  • Woo, Byung-Lyul;Lee, Hyun-Su;Ahn, Ho-Gi;Jung, Soon-Won;Hwang, Moon-Young;Park, Choong-Hee;Yu, Seung-Do;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.61-69
    • /
    • 2011
  • Perceived air quality (PAQ) is defined as evaluation of indoor air satisfaction and comfortable sensory by occupants. However, there are differences between criteria of indoor pollutants and lowest sensory thresholds. In this study, we compared indoor PAQ by questionnaire with measured benzene, toluene and nitrogen dioxide ($NO_2$) concentrations in home indoors. The $NO_2$ concentration was the highest in Seoul, while benzene and toluene were the highest in Asan. Average PAQ score in winter was higher than that in summer. Significant correlations between PAQs of home indoor air pollution and measured pollutant concentrations were not shown and correlation coefficients (r) ranged between -0.453

Carbon-Reduced Titanium Dioxide Production and Characterization Using Dyeing Wastewater Sludge (염색 폐수 슬러지를 활용한 탄소저감형 이산화티타늄 제조 및 특성 분석)

  • Jong Kyu Kim
    • Korean Journal of Materials Research
    • /
    • v.34 no.5
    • /
    • pp.254-260
    • /
    • 2024
  • This study is to manufacture a titanium dioxide (TiO2) photocatalyst by recycling sludge generated using titanium tetrachloride (TiCl4) as a coagulant. Compared to general sewage, a TiCl4 coagulant was applied to dyeing wastewater containing a large amount of non-degradable organic compounds to evaluate its performance. Then the generated sludge was dried and fired to prepare a photocatalyst (TFS). Scanning electron microscope-energy dispersive X-ray spectroscopy (SEM-EDX), X-ray diffraction (XRD), and nitrogen oxide reduction experiments were conducted to analyze the surface properties and evaluate the photoactive ability of the prepared TFS. After using titanium tetrachloride (TiCl4) as a coagulant in the dyeing wastewater, the water quality characteristics were measured at 84 mg/L of chemical oxygen demand (COD), 10 mg/L of T-N, and 0.9 mg/L of T-P to satisfy the discharge water quality standards. The surface properties of the TFS were investigated and the anatase crystal structure was observed. It was confirmed that the ratio of Ti and O, the main components of TiO2, accounted for more than 90 %. As a result of the nitric oxide (NO) reduction experiment, 1.56 uMol of NO was reduced to confirm a removal rate of 20.60 %. This is judged to be a photocatalytic performance similar to that of the existing P-25. Therefore, by applying TiCl4 to the dyeing wastewater, it is possible to solve the problems of the existing coagulant and to reduce the amount of carbon dioxide generated, using an eco-friendly sludge treatment method. In addition, it is believed that environmental and economic advantages can be obtained by manufacturing TiO2 at an eco-friendly and lower cost than before.

Comparison of Five Pollutant Levels between Inside and Outside Homes (主要 汚染物質에 대한 家庭에서의 室內外 濃度比較)

  • 金潤信
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.27-32
    • /
    • 1987
  • As part of an air pollution epidemiological study of asthmatics residing in the Houston area, an air monitoring system provided data on the indoor and outdoor measurements of major pollutant gases sampled at selected residences during May ~ October 1981. Continuously monitored pollutant gases included sulfur dioxide ($SO_2$), nitrogen dioxide($NO_2$), nitric oxide(NO), carbon monoxide(CO), and ozone($O_3$). Outdoor levels for each pollutant were compared with their indoor levels(bedroom, kitchen, living room). Mean concentrations of each pollutant in the kitchen, and living room exceeded the mean levels outside except for ozone, while average bedroom levels for all gases except for $O_3$ and $NO_2$ were found higher than the corresponding outside levels. Indoor/ outdoor ratios for $SO_2$, NO, and CO were 1.8 ~ 2.7 times the outdoor levels, but indoor/ outdoor ratios for $NO_2$ and $O_3$ were 0.99 and 0.06, respectively. The impact of several important household characteristics (type of cooking fuel and cigarette smoking) on the indoor levels for these gases is evaluated.

  • PDF

The Trend of the Concentrations of the Criteria Pollutants over Seoul (서울의 대기환경기준물질 농도 추이)

  • Kim, Yong Pyo;Yeo, Min Ju
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.369-377
    • /
    • 2013
  • The trends of the criteria air pollutants' concentrations over Seoul are reviewed, relative contributions of major sources are discussd, and directions for future air quality management are suggested. It was shown that the yearly average concentrations of the criteria air pollutants except nitrogen dioxide and ozone have decreased significantly over the last three decades. Though the concentration of nitrogen dioxide has not decreased, the concentration of $NO_x$ has decreased significantly. The major reason for the reduction of the criteria air pollutants has been strict government regulations such as establishment of strict emission standards and switch to cleaner fuels. However, it is not clear the major reason (s) for the reduction of the $PM_{10}$ concentration. It is suggested that to further reduce the concentrations of secondary air pollutants such as ozone and $PM_{2.5}$, understanding the major chemical pathways for them is essential. In addition, influence from outside Seoul should be quantified and effectively controlled.

Critical Evaluation of and Suggestions for a Comprehensive Project Based on the Special Act on Seoul Metropolitan Air Quality Improvement (수도권 대기환경 개선사업-진단과 제언)

  • Baek, Sung-Ok;Koo, Youn-Seo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2008
  • On January 1, 2005, the Korean Ministry of Environment put into operation a comprehensive program, so called 'Blue Sky 21' project, for the improvement of air quality in greater Seoul metropolitan area. This program was legally based on the 'Special Act on Metropolitan Air Quality Improvement' for Greater Seoul area, which was established in 2003, and should be updated every 10 years. The principal objective of this program is to improve the air quality in Seoul and surrounding area by 2014 to the levels of air quality in Tokyo and Paris, with particular emphases on reducing the concentrations of nitrogen dioxide and $PM_{10}$. Any regulation of the emission of toxic air pollutants in general, and $NO_2$ and $PM_{10}$ in particular, should be based on human exposure levels and consequential health effects. In this article, the contents and feasibility of the special program were critically evaluated with respect to the reduction of health risks. Important issues for improving not only air quality but public health are discussed, and future requirements for the success of the special program are suggested.

The Simultaneous Absorption Rate of CO2/SO2/NO2 from Flue Gas with Aqueous Alkanolamine Solutions (알카놀아민 수용액을 이용한 연소배가스 중의 CO2/SO2/NO2 동시 흡수속도에 관한 연구)

  • Seo, Jong-Beom;Choi, Won-Joon;Kim, Jae-Won;Choi, Bong-Wook;Oh, Kwang-Joong
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.639-645
    • /
    • 2009
  • In this study, alkanolamine was used to achieve high absorption rates for $CO_2$ as suggested at several literatures. The absorption rates of aqueous AMP and MEA solutions with $CO_2$, $SO_2$, $NO_2$ were measured using a stirredcell reactor. The reaction rate constants were determined from the measured absorption rates. The performances were evaluated under various operating conditions. As a result, the reactions with $SO_2$, $NO_2$ into aqueous AMP and MEA solutions were classified as an instantaneous reaction respectively. The absorption rates increased with increase of the reaction temperature and the concentration of absorbents. The simultaneous absorption rate of $CO_2/SO_2/NO_2$ into 3, 5, 10 wt.% MEA at various pressure of $CO_2/SO_2/NO_2$, was more increased 14~20% than AMP solution. We investigated the effect of $SO_2$ and $NO_2$ on the simultaneous absorption of $CO_2/SO_2/NO_2$ from a flue gas. The performances were evaluated under various operating conditions in order to investigate the absorption characteristic.