• 제목/요약/키워드: Nitrogen Cooling

검색결과 273건 처리시간 0.027초

6.6 ㎸-200A급 HTS 한류기 DC Reactor용 과냉질소 냉각시스템의 개발 (Development of cooling system with sub-cooled nitrogen for DC Reactor of 6.6 ㎸-200A class HTS fault current limiter)

  • 김형진;권기범;강형구;배덕권;안민철;정은수;장호명;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.171-175
    • /
    • 2003
  • The sub-cooled nitrogen cooling system at 65 K with GM cryo-cooler is developed for cooling down the DC reactor of 6.6 ㎸-200 A class HTS Fault Current Limiter(SFCL). The sub-cooled nitrogen cooling is more economic than saturated nitrogen cooling, because the length of HTS wire is reduced in the same capacity, as well as, more stable. The cooling system with the GM cryo-cooler installed on the cryostat is not only compact but also efficient for energy saving. In the nitrogen vessel, after evacuating with vacuum pump to saturated nitrogen at 65 K, sub-cooled nitrogen at 65 K is made by putting in gas helium to 1 atm. During the short circuit test occurring the fault current of 1000 A, the sub-cooled nitrogen cooled DC reactor for SFCL is kept the state of sub-cooled nitrogen at 65 K.

  • PDF

CONTROL OF NITROGEN CONTENT FOR THE IMPROVEMENT OF HAZ

  • Bang, Kook-soo;Kim, Byong-chul;Kim, Woo-yeul
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.229-234
    • /
    • 2002
  • The variation of HAZ toughness with nitrogen content and weld cooling rate was investigated and interpreted in terms of both microstructure and the amount of free nitrogen. The presence of free nitrogen in HAZ was investigated by internal friction measurement and its amount was measured by hydrogen hot extraction analysis. Both nitrogen content and weld cooling rate influenced HAZ microstructure and high toughness was obtained at a mixed microstructure of acicular ferrite, feffite sideplate and polygonal ferrite. If nitrogen content is too low or cooling rate is too fast, bainitic microstructure is obtained and toughness is low. On the other hand, if nitrogen content is too high or cooling rate is too slow, coarse polygonal ferritic microstructure is obtained and toughness is deteriorated again. ill addition to the microstructural change, high nitrogen content also resulted in a large amount of free nitrogen. Therefore, nitrogen content should be kept as low as possible even if the mixed micostructure is obtained. In this experimental condition, the maximum toughness was obtained at 0.006% nitrogen content when weld cooling time ($\Delta$t$_{8}$5/)) is 60s.TEX>5/)) is 60s.

  • PDF

금형 냉각이 Al-Mn계 다중압출 평판관의 압출 특성 변화에 미치는 영향 (Effects of die cooling on change of extrusion characteristics of Al-Mn-based thin-walled flat multi-port tube)

  • 신영철;하성호;강태훈;이기안;이승철
    • Design & Manufacturing
    • /
    • 제17권4호
    • /
    • pp.63-71
    • /
    • 2023
  • In order to increase the extrusion production speed of aluminum, extrusion die cooling technology using liquid nitrogen has recently attracted a lot of attention. Increasing the extrusion speed increases the temperature of the bearing area of extrusion dies and the extrusion profile, which may cause defects on the surface of extruded profile. Extrusion die cooling technology is to directly inject liquid nitrogen through a cooling channel formed between the die and the backer inside the die-set. The liquid nitrogen removes heat from the die-set, and gaseous nitrogen at the exit of the channel, covers the extrusion profile of an inert atmosphere reducing the oxidation and the profile temperature. The aim of this study is to evaluate the cooling capacity by applying die cooling to extrusion of Al-Mn-based aluminum alloy flat tubes, and to investigate the effects of die cooling on the change in extrusion characteristics of flat tubes. Cooling capacity was confirmed by observing the temperature change of the extrusion profile depending on whether or not die cooling is applied. To observe changes in material characteristics due to die cooling, surface observation is conducted and microstructure and precipitate analysis are performed by FE-SEM on the surface and longitudinal cross section of the extruded flat tubes.

한전 초전도전력케이블 냉각시스템 성능시험 (Performance Test of Cooling System for the KEPCO HTS Power Cable)

  • 양형석;김동락;손송호;임지현;최하옥;이병섭;최연석;류희석;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

케로신 내 용존질소 측정 및 제거 방법 연구 (A Study on Measurement and Elimination Methods of Dissolved Nitrogen in Kerosene)

  • 이원구;김성룡;안규복
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.142-148
    • /
    • 2018
  • 발사체 연료 케로신은 발사체의 성능 향상을 위해 고밀도화 과정을 거치게 된다. 고밀도화 방법 중 액체질소 주입 냉각법은 시스템이 간단하고 비용이 저렴한 효과적인 방법이다. 하지만 냉각과정 중 질소가 케로신에 용해되어 물성을 변화시키는 원인이 되기도 한다. 따라서 냉각 후 케로신 내 용존질소의 양을 측정하고 제거하는 작업이 필수적이다. 본 연구에서는 케로신 내 용존질소 함유량을 측정할 수 있는 진공추출 원리를 소개하였다. 또한 질소 샘플링 장치를 설계/제작하여 수행한 실험 결과를 설명하였다. 실험결과로부터 질소 샘플링 장치와 용존질소 측정법/제거법의 유효성을 입증하였다.

고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성 (Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

Al 6061의 열간압출시 질소금형냉각이 압출재의 미세조직에 미치는 영향 (The Influence of Extrudate Microstructure of Die Cooling Using $N_2$ gas in Hot Extrusion for Al 6061 Alloy)

  • 고대훈;이상호;고대철;김병민
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.50-53
    • /
    • 2008
  • It's so difficult to obtain simultaneously both product quality and improvement of the productivity of which products are in hot aluminum extrusion process. But significant improvements in productivity and extrudate quality result from die cooling system using nitrogen gas injection during aluminum hot extrusion. These benefits are due primarily to cooling effect nitrogen gas and removal of excess heat in the extrudate temperature. This investigation is carried out hot extrusion experiment, also compared cooling system with non-cooling system to inspect cooling effects on hot aluminum extrusion. The purpose of this investigation is estimated the grain growth fur the extrudate quality, and the ram speed for the improvement of the productivity.

  • PDF

Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

  • Li, Yuquan;Hao, Botao;Zhong, Jia;Wang, Nan
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.54-70
    • /
    • 2017
  • The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility-the advanced core-cooling mechanism experiment (ACME)-was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups-a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break-were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative effects on the passive core cooling performance caused by nitrogen injection during the SBLOCA transient.

초전도케이블 냉각시스템의 냉각특성 시험 (Test of The HTS Power Cable Cooling System)

  • 염한길;고득용;김익생;김춘동;김도형
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.281-283
    • /
    • 2003
  • High temperature superconducting power cable requires forced flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65K and 80K. Subcooler heat exchanger uses saturated liquid nitrogen boiling on the shell side to subcool the circulating liquid nitrogen stream that cools the HTS cable. The paper describes performance tests of the cooling system. The test items are heat exchanging performance of subcooler. pressure drop between supply and return lines, heat transfer coefficient inside former, cable cryostat heat leak and simulation of electrical load of HTS cable.

  • PDF