DOI QR코드

DOI QR Code

Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

  • Li, Yuquan (State Nuclear Power Technology R&D Center, South Park, Beijing Future Science & Technology City) ;
  • Hao, Botao (State Nuclear Power Technology R&D Center, South Park, Beijing Future Science & Technology City) ;
  • Zhong, Jia (State Nuclear Power Technology R&D Center, South Park, Beijing Future Science & Technology City) ;
  • Wang, Nan (State Nuclear Power Technology R&D Center, South Park, Beijing Future Science & Technology City)
  • Received : 2016.01.09
  • Accepted : 2016.06.30
  • Published : 2017.02.25

Abstract

The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility-the advanced core-cooling mechanism experiment (ACME)-was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups-a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break-were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative effects on the passive core cooling performance caused by nitrogen injection during the SBLOCA transient.

Keywords

References

  1. Y. Bae, Y.I. Kim, K.K. Kim, Transient performance analysis of pressurized safety injection tank with a partition, Ann. Nucl. Energy 75 (2015) 232-238. https://doi.org/10.1016/j.anucene.2014.08.053
  2. S.N. Tower, T.L. Schulz, R.P. Vijuk, Passive and simplified system features for the advanced Westinghouse 600 MWe PWR, Nucl. Eng. Des. 109 (1988) 147-154. https://doi.org/10.1016/0029-5493(88)90153-7
  3. R.A. Matzie, AP1000 will meet the challenges of near-term deployment, Nucl. Eng. Des. 238 (2008) 1856-1862. https://doi.org/10.1016/j.nucengdes.2007.10.035
  4. L. Ma, J. Li, S. Ji, H.J. Chang, Turbulent convection experiment at high Rayleigh number to support CAP1400 IVR strategy, Nucl. Eng. Des. 292 (2015) 69-75. https://doi.org/10.1016/j.nucengdes.2015.05.031
  5. L.M. Shotkin, Y. Kukita, Implications of the ROSA/AP600 high- and intermediate-pressure test results, Nucl. Technol. 119 (1997) 217-234. https://doi.org/10.13182/NT97-A35399
  6. J. Reyes, L. Hochreiter, Scaling analysis for the OSU AP600 test facility (APEX), Nucl. Eng. Des. 186 (1998) 53-109. https://doi.org/10.1016/S0029-5493(98)00218-0
  7. Yutaka Kukita, Taisuke Yonomoto, Hideaki Asaka, Hideo Nakamura, Hiroshige Kumamaru, Yoshinari Anoda, Timothy J. Boucher, Marcos G. Ortiz, Roy A. Shaw, Richard R. Schultz, ROSA/AP600 testing: facility modifications and initial test results, J. Nucl. Sci. Technol. 33 (1996) 259-265. https://doi.org/10.1080/18811248.1996.9731898
  8. R.F. Wright, R. Hundal, L.E. Hochreiter, M.T. Friend, M. Ogrins, Analysis and evaluation of the AP600 SPES-2 integral systems tests, Int. Conf. Nucl. Eng. ASME 2 (1996) 417-425.
  9. M.T. Friend, R.F. Wright, R. Hundal, L.E. Hochreiter, M. Ogrins, Simulated AP600 response to small-break loss-of-coolant-accident and non-loss-of-coolant-accident events: analysis of SPES-2 integral test results, Nucl. Technol. 122 (1998) 19-41. https://doi.org/10.13182/NT98-A2848
  10. R.F. Wright, Simulated AP1000 response to design basis small-break LOCA events in APEX-1000 test facility, Nucl. Eng. Technol. 39 (2007) 287-298. https://doi.org/10.5516/NET.2007.39.4.287
  11. J.N. Reyes Jr., G.T. Groome, A.Y. Lafi, S.C. Franz, C. Rusher, M. Strohecker, D. Wachs, S. Solpo, S. Binney, Final report of NRC AP600 research conducted at Oregon State University, NUREG/CR 6641, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, 1999.
  12. W. Wulff, U.S. Rohatgi, System scaling for the Westinghouse AP600 pressurized water reactor and related test facilities, NUREG/CR-5541, BNL-NUREG-52550, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, 1998, 1-1 - 9-2.
  13. K.B. Welter, S.M. Bajorek, Reyes Jose Jr., Woods Brain, Groome John, Hopson John, Youny Eric, DeNoma John, Abel Kent, APEX-AP1000 confirmatory testing to support AP1000 Design Certification (Non-Proprietary), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, 2005, 1-1 - 7-2, NUREG-1826.
  14. Z.M. Meng, B. Dong, L.S. Wang, X.L. Fu, W.X. Tian, Y.H. Yang, G.H. Su, Experimental research of liquid entrainment through ADS-4 in AP1000, Ann. Nucl. Energy 72 (2014) 428-437. https://doi.org/10.1016/j.anucene.2014.06.012
  15. K.B. Welter, Q. Wu, Y. You, K. Abel, D. McCreary, S.M. Bajorek, J.N. Reyes Jr, Experimental investigation and theoretical modeling of liquid entrainment in a horizontal tee with a vertical-up branch, Int. J. Multiphase Flow 30 (2004) 1451-1483. https://doi.org/10.1016/j.ijmultiphaseflow.2004.08.001
  16. Z.M. Meng, X.L. Fu, L. Ding, B. Dong, W.X. Tian, Y.H. Yang, G.H. Su, Experimental and theoretical investigation of liquid entrainment through small-scale ADS-4 in AP1000, Exp. Thermal Fluid Sci. 57 (2014) 177-187. https://doi.org/10.1016/j.expthermflusci.2014.04.022
  17. Z.M. Meng, L.F. Liu, L. Ding, X.L. Fu, W.X. Tian, Y.H. Yang, G.H. Su, Comparative study on effect of air-water and steam-water mediums on liquid entrainment through ADS-4 in AP1000, Exp. Thermal Fluid Sci. 69 (2015) 149-157. https://doi.org/10.1016/j.expthermflusci.2015.06.002
  18. W.W. Wang, G.H. Su, Z.M. Meng, W.X. Tian, S.Z. Qiu, Analyses of liquid entrainment through ADS-4 in AP1000 during a typical small break LOCA transient, Ann. Nucl. Energy 60 (2013) 195-201. https://doi.org/10.1016/j.anucene.2013.05.006
  19. W.W. Wang, G.H. Su, S.Z. Qiu, W.X. Tian, Thermal hydraulic phenomena related to small break LOCAs in AP1000, Prog. Nucl. Energy 53 (2011) 407-419. https://doi.org/10.1016/j.pnucene.2011.02.007
  20. H.J. Chang, Y.Q. Li, Q. Wu, Z.S. Ye, L. Chen, A new integral test facility ACME for passive safety PWR, ANS Winter Meeting, 2012, November 11-15, San Diego, CA.
  21. L. Chen, H.J. Chang, Y.Q. Li, Z.S. Ye, B.K. Qin, Analysis on working pressure selection of ACME integral test facility, Atomic Energy Sci. Technol. 45 (2011) 1215-1220.
  22. G.E. Wilson, B.E. Boyack, The role of the PIRT process in experiments, code development and code applications associated with reactor safety analysis, Nucl. Eng. Des. 186 (1998) 23-27. https://doi.org/10.1016/S0029-5493(98)00216-7
  23. Zuber Novak, Gary E. Wilson, Ishii Mamoru, Wulff Wolfgang, B.E. Boyack, A.E. Dukler, P. Griffith, J.M. Healzer, R.E. Henry, J.R. Lehner, S. Levy, F.J. Moody, M. Pilch, B.R. Sehgal, B.W. Spencer, T.G. Theofanous, J. Valente, An integrated structure and scaling methodology for severe accident technical issue resolution: development of methodology, Nucl. Eng. Des. 186 (1998) 1-21. https://doi.org/10.1016/S0029-5493(98)00215-5
  24. Y.Q. Li, H. Wang, Z.S. Ye, L. Chen, B.K. Qin, ACME test facility scaling analysis report (Ver. A), State Nuclear Power Research and Development Center, Beijing, 2012, p. K001BG0016.
  25. T. Zhang, M.T. Cui, F. Tian, Uncertainty Budget of ACME Instrumentation System(Ver. A), State Nuclear Power Research and Development Center, Beijing, 2014, p. K001BG0052.
  26. D.C. Sun, Y. Xiang, W.X. Tian, J.C. Liu, P. Zhang, S.Z. Qiu, G.H. Su, Experimental investigation of upper plenum entrainment in AP1000, Prog. Nucl. Energy 80 (2015) 80-85. https://doi.org/10.1016/j.pnucene.2014.12.003
  27. R. Sander, Compilation of Henry's law constants (version 4.0) for water as solvent, Atmos. Chem. Phys. 15 (2015) 4399-4981. https://doi.org/10.5194/acp-15-4399-2015