• 제목/요약/키워드: NiMo

검색결과 651건 처리시간 0.027초

ADI의 미세조직과 기계적 특성에 미치는 특수열처리 및 합금원소의 영향 (Effects of Special Heat Treatments and Alloying Elements on the Microstructures and Mechanical Charateristics of ADI)

  • 김석원;한상원;이의종;박진성;우기도;김동건
    • 한국주조공학회지
    • /
    • 제22권2호
    • /
    • pp.69-74
    • /
    • 2002
  • The effects of heat treatments and alloying elements on the microstructure and mechanical charaterisitics of specially austempered ADIs containing alloying elements such as Cu, Mo and Ni were investigated. To compare with the effect of conventional and normal(CN) austempering treatment, two kinds of special austempering treatments which are those with pre-quenching and pre-heating were conducted. The hardness and uniaxial fatigue tests were carried out to evaluate the mechanical charateristics. The hardness of ADI treated by CN heat cycles was higher than those of other ADIs. Cu added ADI (Cu-ADI) tempered at 400 after austenitizing exhibited the highest fatigue life cycles. While austempering after prequenching makes the austenite with high carbon stable, which resulted in transformation to highly strengthened bainites from the carbon enriched austenite phases during tempering. The high carbon enriched banites is considered to improve the fatigue strength.

원전 해수 펌프 임펠러 합금의 케비테이션 피로 손상 해석 (An Analysis on Fatigue Fracture of Nuclear Pump Impeller Alloys by Ultrasonic Vibratory Cavitation Erosion)

  • 홍성모;이민구;김광호;이창규
    • 한국표면공학회지
    • /
    • 제39권1호
    • /
    • pp.35-42
    • /
    • 2006
  • In this study, the fatigue properties on the cavitation damage of the flame quenched 8.8Al-bronze (8.8Al-4.5Ni-4.5Fe-Cu) as well as the current nuclear pump impeller materials (8.8Al-bronze, STS316 and SR50A) has been investigated using an ultrasonic vibratory cavitation test. For this the impact loads of cavitation bubbles generated by ultrasonic vibratory device quantitatively evaluated and simultaneously the cavitation erosion experiments have been carried out. The fatigue analysis on the cavitation damage of the materials has been made from the determined impact load distribution (e.g. impact load, bubble count) and erosion parameters (e.g. incubation period, MDPR). According to Miner's law, the determined exponents b of the F-N relation ($F^b$ N = Constant) at the incubation stage (N: the number of fracture cycle) were 5.62, 4.16, 6.25 and 8.1 for the 8.8Al-bronze, flame quenched one, STS316 and SR50A alloys. respectively. At the steady state period, the exponents b of the F-N' curve (N': the number of cycle required for $1{\mu}m$ increment of MDP) were determined as 6.32, 5, 7.14 and 7.76 for the 8.8Al-bronze, flame quenched one, STS316, and SR50A alloys, respectively.

A design of transmission-type multi-target X-ray tube based on electric field modulation

  • Zhao, Lei;Jia, Wenbao;Jin, Limin;Shan, Qing;Cheng, Can;Zhu, Hongkui;Hei, Daqian
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3026-3034
    • /
    • 2021
  • Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 105 V/m electric field. The focus areas are about 2 mm × 5 mm and 4 mm × 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mm and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively.

Effects of superimposed cyclic operation on corrosion products activity in reactor cooling system of AP-1000

  • Mahmood, Fiaz;Hu, Huasi;Lu, Guichi;Ni, Si;Yuan, Jiaqi
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1109-1116
    • /
    • 2019
  • It is essential to predict the radioactivity distribution around the reactor cooling system (RCS) during obligatory cyclic operation of AP-1000. A home-developed program CPA-AP1000 is upgraded to predict the response of activated corrosion products (ACPs) in the RCS. The program is written in MATLAB and it uses state of the art MCNP as a subroutine for flux calculations. A pair of cyclic power profiles were superimposed after initial full power operation. The effect of cyclic operation is noticed to be more prominent for in-core surfaces, followed by the primary coolant and out-of-core structures. The results have shown that specific activity trends of $^{56}Mn$ and $^{24}Na$ promptly follow the power variations, whereas, $^{59}Fe$, $^{58}Co$, $^{99}Mo$ and $^{60}Co$ exhibit a sluggish power-following response. The investigations pointed out that promptly power-following response of ACPs in the coolant is vital as an instant radioactivity source during leakage incidents. However, the ACPs with delayed power-following response in the out-of-core components are perceived to cause a long-term activity. The present results are found in good agreement with those for a reference PWR. The results are useful for source term monitoring and optimization of work procedures for an innovative reactor design.

고질소 2상 스테인리스강의 고온 석출거동 (High Temperature Precipitation Behavior of High-Nitrogen Duplex Stainless Steel)

  • 배종인;김성태;이태호;하헌영;김성준;박용호
    • 대한금속재료학회지
    • /
    • 제49권2호
    • /
    • pp.93-103
    • /
    • 2011
  • Precipitation behavior of high-nitrogen duplex Fe-24Cr-7Mn-4Ni-4Mo-0.43N stainless steel aged at $850^{\circ}C$ was investigated using scanning transmission electron microscopy. Based on the analyses of selected area diffraction patterns, four kinds of precipitates (intermetallic sigma (${\sigma}$) and chi (${\chi}$), $Cr_2N$ and secondary austenite) were identified. At the ferrite/austenite phase boundary, the ${\sigma}$ phase and secondary austenite were formed via ${\alpha}{\rightarrow}{\gamma}+{\sigma}$ eutectoid reaction. The precipitation of $Cr_2N$ occurred at the austenite grain boundary as well as the interior of the ferrite. The intermetallic ${\chi}$ phase also formed within the ferrite and showed a cube-cube orientation relationship with the ferrite. Further aging produced a lamellar structure composed of $Cr_2N$ and austenite along the ferrite/austenite boundary and enhanced the precipitation of the ${\chi}$ phase. The crystallographic features of the precipitates were also examined in terms of the orientation relationship with the austenite or ferrite matrix.

Corrosion of Containment Alloys in Molten Salt Reactors and the Prospect of Online Monitoring

  • Hartmann, Thomas;Paviet, Patricia
    • 방사성폐기물학회지
    • /
    • 제20권1호
    • /
    • pp.43-63
    • /
    • 2022
  • The aim of this review is to communicate some essential knowledge of the underlying mechanism of the corrosion of structural containment alloys during molten salt reactor operation in the context of prospective online monitoring in future MSR installations. The formation of metal halide species and the progression of their concentration in the molten salt do reflect containment corrosion, tracing the depletion of alloying metals at the alloy salt interface will assure safe conditions during reactor operation. Even though the progress of alloying metal halides concentrations in the molten salt do strongly understate actual corrosion rates, their prospective 1st order kinetics followed by near-linearly increase is attributed to homogeneous matrix corrosion. The service life of the structural containment alloy is derived from homogeneous matrix corrosion and near-surface void formation but less so from intergranular cracking (IGC) and pitting corrosion. Online monitoring of corrosion species is of particular interest for molten chloride systems since besides the expected formation of chromium chloride species CrCl2 and CrCl3, other metal chloride species such as FeCl2, FeCl3, MoCl2, MnCl2 and NiCl2 will form, depending on the selected structural alloy. The metal chloride concentrations should follow, after an incubation period of about 10,000 hours, a linear projection with a positive slope and a steady increase of < 1 ppm per day. During the incubation period, metal concentration show 1st order kinetics and increasing linearly with time1/2. Ideally, a linear increase reflects homogeneous matrix corrosion, while a sharp increase in the metal chloride concentration could set a warning flag for potential material failure within the projected service life, e.g. as result of intergranular cracking or pitting corrosion. Continuous monitoring of metal chloride concentrations can therefore provide direct information about the mechanism of the ongoing corrosion scenario and offer valuable information for a timely warning of prospective material failure.

용접사업장 근로자의 흄 및 금속 노출농도에 대한 평가와 혈중 금속 농도 (Airborne Concentrations of Welding Fume and Metals of Workers Exposed to Welding Fume)

  • 최호춘;김강윤;안선희;박화미;김소진;이영자;정규철
    • 한국산업보건학회지
    • /
    • 제9권1호
    • /
    • pp.56-72
    • /
    • 1999
  • Airborne concentrations of welding fumes in which 13 different metals such as Al, Cd, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Si, Sn, Ti, and Zn were analyzed were measured at 18 factories including automobile assembly and manufactures, steel heavy industries and shipyards. Air samples were collected by personal sampler at each worker's worksite(n=339). Blood levels of Cd, Cu, Fe, Mn, Pb and Zn were also measured from samples taken from 447 welders by atomic absorption spectrometry and compared with control values obtained from 127 non-exposed workers. The results were as follows ; 1. Among various welding types, $CO_2$ welding 70.2 % were widely used, shielded metal arc welding(SMAW) 22.1 % came next, and rest of them were metal inert gas(MIG) welding, submerged arc welding(SAW), spot welding(SPOT) and tungsten inert gas(TIG) welding. 2. Welding fume concentration was $0.92mg/m^3$($0.02{\sim}15.33mg/m^3$) at automobile assembly and manufactures, $4.10mg/m^3$($0.02{\sim}70.75mg/m^3$) at steel heavy industries and $5.59mg/m^3$($0.30{\sim}91.16mg/m^3$) at shipyards, respectively, showing significant difference among industry types. Workers exposed to high concentration of welding fumes above Korean Permissible Exposure Limit(KPEL) amounted to 7.9 % and 12.5 %, in $CO_2$ welding and in SMAW at automobile assembly and manufactures and 62.7 % in $CO_2$ welding, and 12.5 % in SMAW at shipyards, and 66.2 % in $CO_2$ welding and 70.6 % in SMAW at steel heavy industries. 3. Geometric mean of airborne concentration of each metal released from welding fumes was below one 10th of KPEL in all welding types. Percentage of workers, however, exposed to airborne concentration of metals above KPEL amounted to 16.8 % in Mn and 7.6 % in Fe in $CO_2$ welding; 37.5 % in Cu in SAW, 30 % in Cu in TIG; and 25 % in Pb in SPOT welding. As a whole, 76 Workers(22.4%) were exposed to high concentration of any of the metals above KPEL. 4. There were differences in airborne concentration of metals such as Al, Cd, Cr, Cu. Fe. Mn, Mo, Ni, Pb, Si, Sn, Ti and Zn by industry types. These concentrations were higher in shipyards and steel heavy industries than in automobile assembly and manufactures. Workers exposed to higher concentration of Pb above KPEI amounted to 7.4 % of workers(7/94) in automobile assembly and manufactures. In shipyards, 19.2 % of workers(19/99) were over-exposed to Mn and 7.1 % (7/99) to Fe above KPEL. In steel heavy industries, 14.4 %(21/146), 7.5 %(11/146) and 13 %(19/146) were over-exposed to Mn, Fe and Cu, respectively. As a whole, 76 out of 339 workers(22.4%) were exposed to any of the metals above KPEL. 5. Blood levels of Cd, Cu, Fe, Mn, Pb, and Zn in welders were $0.11{\mu}g/100m{\ell}$, $0.84{\mu}g/m{\ell}$, $424.4{\mu}g/m{\ell}$, $1.26{\mu}g/100m{\ell}$, $5.01{\mu}g/100m{\ell}$ and $5.68{\mu}g/m{\ell}$, respectively, in contrast to $0.09{\mu}g/100m{\ell}$, $0.70{\mu}g/m{\ell}$, $477.2{\mu}g/m{\ell}$, $0.73{\mu}g/100m{\ell}$, $3.14{\mu}g/100m{\ell}$ and $6.15{\mu}g/m{\ell}$ in non-exposed control groups, showing significantly higher values in welders but Fe and Zn.

  • PDF

수유기간별 모유의 주요 무기질 및 미량원소 함량 변화 (Changes in the Contents of Major Minerals and Trace Elements of Human Milk During the Breast-Feeding)

  • 안홍석
    • Journal of Nutrition and Health
    • /
    • 제25권2호
    • /
    • pp.123-131
    • /
    • 1992
  • 한국인 수유부 21명의 모유에 함유된 무기질(Na, K, Ca, P, Mg)과 일부 미량원소(Mn, Mo, Ni)의 함량을 경시적으로 초유부터 12주의 성숙유에 이르기 까지 일정한 간격으로 세분하여 비교 분석하였다. 모유에 함유된 5종의 무기질과 8종의 미량원소들의 함량은 수유기간에 따라 유의적으로 감소하였다. 모유의 평균 나트륨 함량은 초유에서 293.01$\mu\textrm{g}$/$m\ell$, 이행유에서는 $251.24$\mu\textrm{g}$/m\ell$ 그리고 성숙유에서 $199.17$\mu\textrm{g}$/m\ell이었으며$ 칼륨농도는 각각 $436.18$\mu\textrm{g}$/m\ell,458.90,$ $390.10$\mu\textrm{g}$/m\ell이었다.$ 초유, 이행유 및 성숙유의 평균 칼슘 농도는 각각 $378.88$\mu\textrm{g}$/m\ell,$ $379.41$\mu\textrm{g}$/m\ell$ 그리고 $338.58$\mu\textrm{g}$/m\ell로$ 측정되었고 모유의 Ca/P의 비는 각각 3.39, 2.81과 2.45이었다. 또한 마그네슘 함량은 초유와 이행유에서 각각 $37~38$\mu\textrm{g}$/m\ell이었고$ 성숙유에서 $33.37$\mu\textrm{g}$/m\ell로$ 분석되었다. 모유의 평균 망간 함량은 초유와 이행유에서 각각 $0.024$\mu\textrm{g}$/m\ell,$ 성숙유에서 $0.014$\mu\textrm{g}$/m\ell,$ 믈리브덴의 평균 농도는 각각 $0.035$\mu\textrm{g}$/m\ell,$ $0.044$\mu\textrm{g}$/m\ell$ 그리고 $0.044$\mu\textrm{g}$/m\ell이었고$ 니켈 함량은 초유에서 $0.062$\mu\textrm{g}$/m\ell이행유에서$ $0.022$\mu\textrm{g}$/m\ell,$ 성숙유에서 $0.017$\mu\textrm{g}$/m\ell이었다.$ 수유기간에 따른 모유내 무기질과 미량원소 함량의 감소가 영아의 성장발달과 어떻해 관련 되는가에 관한 연구와 함께 유선조직에서 유즙으로의 무기질과 미량원소의 분비기전에 관한 생리학적 연구가 병행되어야 하겠으며, 본 연구결과가 앞으로 우수한 조제분유나 기타 영아식 개발에 활용되고, preterm milk의 무기질 성분을 비교하는데 이용될 수 있기를 희망한다.

  • PDF

제주지역 PM10의 수농도 및 질량농도와 원소성분 조성 특성 (Characteristics of the Number and the Mass Concentrations and the Elemental Compositions of PM10 in Jeju Area)

  • 강창희;허철구
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.447-457
    • /
    • 2014
  • The number concentrations, the mass concentrations and the elemental concentrations of $PM_{10}$ have measured at Gosan site in Jeju, Korea, from March 2010 to December 2010. And the correlation and the factor analysis for the number, the mass and the elemental concentrations of $PM_{10}$ are performed to identify their relationships and sources. The average $PM_{10}$ number concentration is observed $246\;particles/cm^3$($35.7{\sim}1,017\;particles/cm^3$) and the average $PM_{10}$ mass concentration is shown $50.1{\mu}g/m^3$($16.7{\sim}441.4{\mu}g/m^3$) during this experimental period. The number concentrations are significantly decreased with increasing particle size, hence the concentrations for the smaller particles less than $2.5{\mu}m$($PM_{2.5}$) are contributed 99.6% to the total $PM_{10}$ number concentrations. The highest concentration of the 20 elements in $PM_{10}$ determined in this study is shown by S with a mean value of $1,497ng/m^3$ and the lowest concentration of them is found by Cd with a mean value of $0.57ng/m^3$. The elements in $PM_{10}$ are evidently classified into two group based on their concentrations: In group 1, including S>Na>Al>Fe>Ca>Mg>K, the elemental mean concentrations are higher than several hundred $ng/m^3$, on the other hand, the concentrations are lower than several ten $ng/m^3$ in group 2, including Zn>Mn>Ni>Ti>Cr>Co>Cu>Mo>Sr>Ba>V>Cd. The size-separated number concentrations are shown positively correlated with the mass concentrations in overall size ranges, although their correlation coefficients, which are monotonously increased or decreased with size range, are not high. The concentrations of the elements in group 1 are shown highly correlated with the mass concentrations, but the concentrations in group 2 are shown hardly correlated with the mass concentrations. The elements originated from natural sources have been predominantly related to the mass concentrations while the elements from anthropogenic sources have mainly affected on the number concentrations of $PM_{10}$.

감압잔사유 수첨분해반응의 생성물 분석방법 비교 (Comparison of Analytical Methods of Products in Hydrocracking of Vacuum Residue)

  • 권혁민;김한나;웬후이친;김도경;김도완;오승훈;신은우
    • 청정기술
    • /
    • 제17권1호
    • /
    • pp.56-61
    • /
    • 2011
  • 감압잔사유를 고압 회분식 반응기에 넣고, 상용 Ni-Mo/$Al_2O_3$ 촉매를 이용하여 $450^{\circ}C$, $500^{\circ}C$에서 수첨분해하였다. 그리고 반응 생성물을 단증류 혹은 GC-SIMDIS 방법으로 각각 분석하였다. 먼저 수첨분해반응에서는 두 온도 조건 모두 촉매 반응뿐만 아니라 열분해 반응도 같이 일어나고 있음을 확인하였고, 온도가 증가할수록 전환율이 증가하고, 생성물 중 가솔린 및 납사 비율이 높아졌다. 생성물 분석 결과, $500^{\circ}C$ 반응에서는 단증류와 GC-SIMDIS 분석 결과의 차이가 없었지만, $450^{\circ}C$ 반응에서는 단증류에서는 디젤이, GC-SIMDIS에서는 vacuum gas oil이 주 생성물로 드러났다. 이는 $450^{\circ}C$ 반응에서의 단증류 분석은 단증류에 의한 열분해 반응으로 인해 생성물의 선택도가 정확하지 않음을 알려준다.