• 제목/요약/키워드: Ni-ions

검색결과 514건 처리시간 0.04초

Defects evolution and element segregation of Ni-Mo-Cr alloy irradiated by 30 keV Ar ions

  • Liu, Min;Liu, Wenguan;He, Xiujie;Gao, Yantao;Liu, Renduo;Zhou, Xingtai
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1749-1755
    • /
    • 2020
  • In present study, TEM foils of Ni-Mo-Cr alloy were directly irradiated with 30 keV Ar ions to allow direct characterization. The defects evolution and element segregation after irradiation were investigated by TEM and HAADF-EDS linear scanning. At low irradiation doses (1.38 and 2.76 dpa), black dots were formed and grew with increasing dose. Complicated defects including peas-shaped dislocation loops, polygon dislocation networks and large loops were visible in samples irradiated to high doses (13.8 and 27.6 dpa). Meanwhile, dislocation channels appeared, in which defects were swept out. Significant Mo depletions at dislocation lines and grain boundaries were induced by irradiation due to large misfits between Mo-Ni atoms and high content of Mo.

NiZn Ferrite Coating for Electrical Insulation of MnZn Ferrite Cores

  • Kitamoto, Y.;Yajima, H.;Nakayama, Y.;Abe, M.
    • 한국세라믹학회지
    • /
    • 제38권6호
    • /
    • pp.506-508
    • /
    • 2001
  • The ferrite plating with applying power ultrasound waves of 19.5 kHz and 600W enabled us to encapsulate entirely MnZn ferrite cores for transformers with Ni$\sub$x/Zn$\sub$y/Fe$\sub$3-x-y/O$_4$coating. Supplying a NH$_4$OH solution during the plating broke the limit of the solubility of Ni ions to ferrite-plated films. The electrical resistivity of the NiZn ferrite coating increased with increasing the Ni and Zn content, reaching 2.3${\times}$10$\^$5/Ωcm at the composition of Ni$\sub$0.24/Zn$\sub$0.30/Fe$\sub$2.46/O$_4$. The saturation magnetization was 540 emu/㎤. As a result, the MnZn ferrite cores were successfully encapsulated with the NiZn ferrite coatings for an insulation layer.

  • PDF

전산모사를 활용한 Fe-Cr-Ni 전주용 수용액의 안정성 분석 (Computational Analysis of Aqueous Solution Stability for Electroformed Fe-Cr-Ni Thin Layer)

  • 전승환;한상선;김마로;최용;이상범
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.214-214
    • /
    • 2014
  • Computational analysis of aqueous solution stability of Fe-Cr-Ni system to find an electroplating condition of Fe-Cr-Ni layer. Aqueous sulfate solution with iron, chromium and nickel ions was selected by using a numerical S/W with which aqueous solution stability was analyzed. Several possible conditions to perform electro-forming of Fe-Cr-Ni were selected with thermo-dynamical data. The Fe-Cr-Ni system was electro-formed which composition and microstructure of the electroplated Fe-Cr-Ni significantly depended on the solution temperature and electro-potential. The final composition of Fe-3%Cr-48%Ni with less than $30{\mu}m$ thick was well electroplated.

  • PDF

M(1)-Ni(5)/AlCeO3 (M = La, Ce, Y) 촉매상에서 수소 제조를 위한 메탄의 부분산화반응에서 La의 효과 (Effect of La in Partial Oxidation of Methane to Hydrogen over M(1)-Ni(5)/AlCeO3 (M = La, Ce, Y) Catalysts)

  • 서호준
    • 공업화학
    • /
    • 제30권6호
    • /
    • pp.757-761
    • /
    • 2019
  • 고정층 상압 유통식 반응기를 사용하여 M(1)-Ni(5)/AlCeO3 (M = La, Ce, Y) 촉매상에서 메탄의 부분 산화 반응을 수행하여 수소의 수율을 조사하였다. XRD 분석으로 반응 전과 반응 후의 환원된 La(1)-Ni(5)/AlCeO3 촉매의 결정상 특성피크를 조사하였고 FESEM과 EDS 분석으로 La, Ni, Ce 금속 입자가 촉매 표면상에 균일하게 분포하고 있음을 조사하였다. XPS 분석으로 촉매 표면상에 O2-, O22-의 산소와 Ce3+, Ce4+, La3+, Ni2+ 등의 이온이 존재함을 알 수 있었고, Ni(5)/AlCeO3 촉매에 1 wt%의 La를 첨가하면 Ni2p3/2과 Ce3d5/2의 원자가 각각 52.7과 6.3%로 증가하였다. La(1)-Ni(5)/AlCeO3 촉매상에서 수소의 수율은 89.1%이었으며, M(1)-Ni(5)/AlCeO3 (M = Ce, Y)보다 매우 우수하였다. AlCeO3이 산소와 반응하여 만들어진 CeO2의 Ce4+ 이온이 La3+로 치환됨으로서 격자에 산소 빈자리를 만들고 strong metal-support interaction (SMSI) 효과로 Ni 원자의 분산을 증가시켜 수소 수율를 향상시켰다.

무전해 니켈/금도금에서의 내부 금속층의 결함에 대한 연구 (A Study of the fracture of intermetallic layer in electroless Ni/Au plating)

  • 박수길;정승준;김재용;엄명헌;엄재석;전세호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.708-711
    • /
    • 1999
  • The Cu/Ni/Au lamellar structure is extensively used as an under bump metallization on silicon file, and on printed circuit board(PCB) pads. Ni is plated Cu by either electroless Ni plating, or electrolytic Ni plating. Unlike the electrolytic Ni plating, the electroless Ni plating does not deposit pure Ni, but a mixture of Ni and phosphorous, because hypophosphite Is used in the chemical reaction for reducing Ni ions. The fracture crack extended at the interface between solder balls of plastic ball grid (PBGA) package and conducting pads of PCB. The fracture is duets to segregation at the interface between Ni$_3$Sn$_4$intermetallic and Ni-P layer. The XPS diffraction results of Cu/Ni/Au results of CU/Ni/AU finishs showed that the Ni was amorphous with supersaturated P. The XPS and EDXA results of the fracture surface indicated that both of the fracture occurred on the transition lesion where Sn, P and Ni concentrations changed.

  • PDF

Separation of cadmium and chromium heavy metals from industrial wastewater by using Ni-Zn nanoferrites

  • Thakur, Atul;Punia, Pinki;Dhar, Rakesh;Aggarwal, R.K.;Thakur, Preeti
    • Advances in nano research
    • /
    • 제12권5호
    • /
    • pp.457-465
    • /
    • 2022
  • The potentials of NixZn1-xFe2O4 (x = 0.0, 0.2, 0.4, 0.6, 0.8 and 1.0) nanoadsorbents were investigated for removal of Cd and Cr from contaminated water from an electroplating industry in Himachal Pradesh, India. Optimal values were recorded under batch adsorption experiments performed to remove dissolved heavy metal ions from industrial wastewater. The specific surface area (SSA) of nanoadsorbents perceived to vary in a range 35.75-45.29 cm2/g and was calculated from the XRD data. The influence of two operating parameters, contact time and dopant (Ni) concentration was also investigated at pH ~7 with optimum dosage. Kinetic studies were conducted within a time range of 2-10 min with rapid adsorption of cadmium and chromium ions onto Ni0.2Zn0.8Fe2O4 nanoadsorbents. Pseudo-second-order kinetic model was observed to be well fitted with the adsorption data that confirmed the only existence of chemisorption throughout the adsorption process. The maximum adsorption efficiency values observed for Cd and Cr were 51.4 mg/g and 40.12 mg/g, respectively for different compositions of prepared series of nanoadsorbents. The removal percentage of Cd and Cr was found to vary in a range of 47.7%-95.25% and 21%-50% respectively. The prepared series of nanoferrite found to be suitable enough for adsorption of both heavy metal ions.

습식 직접 합성법에 의한 Ni-Zn Ferrite 분말의 합성 (Synthesis of Ni-Zn Ferrite Powder by wet direct method)

  • 김한근;지상량;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.217-220
    • /
    • 1991
  • Ni-Zn ferrite powders in the few hundred angstrum size range and up have been synthesized by a wet direct method. The coprecipitate were prepared by adding alkaline solution into the constituent metal ions solution. and subsequent calcined at various temperature. At 95, the particles were ultrafine spherical shaped particles of about 500(A) in diameter.

  • PDF

무정형 알루미나에서의 Ni(II), Co(II), Sr(II) 흡착의 표면착물 모델링 (Surface Complexation Modeling of Ni(II), Co(II), and Sr(II) Adsorption on Amorphous Alumina)

  • 박영재;박경균;서무열;윤수경;최광순;지광용;김원호
    • 대한화학회지
    • /
    • 제44권4호
    • /
    • pp.305-310
    • /
    • 2000
  • 일정한 이온강도(0.1M)에서 알루미나에 의한 Ni(II), Co(II), Sr(II) 및 Cs(I)의 흡착거동을 세 가지의 금속이온 농도를 사용하여 pH를 변화시키면서 관찰하였다. 금속 이온의 농도가 증가할수록 흡착률은 감소했으며 흡착변곡점이 보다 높은 pH쪽으로 이동하였다. 금속 이 온의 농도가 $1.0{\times}10^{-4}$M인 조건에서 측정한 흡착데이터로부터 표면착물 모델을 적용하여 각 금속의 흡착종에 대한 고유의 흡착상수 값을결정하였다. 흡착 세기는 Co(II)>Ni(II)>Sr(II)순으로 감소하였으며 Cs(I)는 흡착이 되지 않았다. 높은 pH에서의 Co(II)와 Ni(II)의 흡착성이 대부분이 가수분해된 형태로 존재하였다.

  • PDF

$CuCl_2-NiCl_2-CoCl_2$용액으로부터 Alamine336과 LIX84에 의한 구리의 용매추출 (Solvent Extraction of Copper from $CuCl_2-NiCl_2-CoCl_2$ Solutions by Alamine336 and LIX84)

  • 이만승;안종관;안재우
    • 자원리싸이클링
    • /
    • 제11권6호
    • /
    • pp.12-17
    • /
    • 2002
  • $CuCl_2$-$NiCl_2$-$CoCl_2$용액으로부터 구리를 분리하기 위해 추출제로 Alamine336과 LIX84를 사용하여 추출실험을 하였다. 염산용액에서 Alamine336과 LIX84에 의한 구리, 코발트, 니켈의 분배계수와 구리의 분리계수는 금속이온과 염소이온간에 형성되는 착물의 농도에 큰 영향을 받았다. 염소이온농도가 0.5에서 4.0M사이인 용액에서 코발트로부터 구리의 분리성은 LIX84가 Alamine336보다 우수하였다. 염소이온농도가 1.0M인 용액에서 LIX84와 Alamine336의 부피백분율을 5에서 40%까지 변화시켜 추출한 결과 LIX84로 추출하는 경우 Alamine336에 비해 더 높은 구리의 분리계수를 얻었다.