• Title/Summary/Keyword: Ni-P thickness

Search Result 93, Processing Time 0.03 seconds

Characterization of GaN on GaN LED by HVPE method

  • Jung, Se-Gyo;Jeon, Hunsoo;Lee, Gang Seok;Bae, Seon Min;Kim, Kyoung Hwa;Yi, Sam Nyung;Yang, Min;Ahn, Hyung Soo;Yu, Young Moon;Kim, Suck-Whan;Cheon, Seong Hak;Ha, Hong Ju;Sawaki, Nobuhiko
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc1
    • /
    • pp.128-131
    • /
    • 2012
  • The selective area growth light emitting diode on GaN substrate was grown using mixed-source HVPE method with multi-sliding boat system. The GaN substrate was grown using mixed-source HVPE system. Te-doped AlGaN/AlGaN/Mg-doped AlGaN/Mg-doped GaN multi-layers were grown on the GaN substrate. The appearance of epi-layers and the thickness of the DH was evaluated by SEM measurement. The DH metallization was performed by e-beam evaporator. n-type metal and p-type metal were evaporated Ti/Al and Ni/Au, respectively. At the I-V measurement, the turn-on voltage is 3 V and the differential resistance is 13 Ω. It was found that the SAG-LED grown on GaN substrate using mixed-source HVPE method with multi-sliding boat system could be applied for developing high quality LEDs.

Bending Mode Multilayer Actuator Using Low Temperature Sintering Piezoelectric Ceramics (저온소결 세라믹을 이용한 밴더형 적층 액츄에이터의 제작)

  • Lee, Ju-Young;Kim, Sang-Jong;Kang, Chong-Yun;Kim, Hyun-Jai;Lee, Sang-Yoel;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.68-69
    • /
    • 2005
  • Low temperature ($\leq900^{\circ}C$) sintering piezoelectric ceramics $0.01Pb(Mg_{1/2}W_{1/2})O_3$-0.41Pb$(Ni_{1/3}Nb_{2/3})O_3-0.35PbTiO_3-0.23PbZrO_3+0.1wt%Y_2O_3+xwt%ZnO$ $(0{\leq}x{\leq}2.5)$ have been developed and investigated. The electromechanical coupling coefficient ($k_p$), piezoelectric constant ($d_{33}$), and mechanical quality factor ($Q_m$) have been measured to characterize the piezoelectric materials system. When 2.0 wt% ZnO is added, the properties of the system, $d_{33}$ = 559 pC/N, $k_p$ = 55.0 % and $Q_m$ = 73.4 are obtained which are very suitable for piezoelectric actuators. A bending mode multilayer actuator has been also developed using the materials which size is $27(L)\times9(W)\times1.07(t)mm^3$. The actuators are fabricated by multilayer ceramic (MLC) process and consist of24 layers and each layer thickness is $35{\mu}m$. At this time, the displacement of actuator was $100{\mu}m$ at 28V.

  • PDF

Mechanical reliability of Sn-37Pb BGA solder joints with high-speed shear test (고속전단 시험을 이용한 Sn-37Pb BGA solder joints의 기계적 신뢰성 특성 평가)

  • Jang, Jin-Kyu;Ha, Sang-Su;Ha, Sang-Ok;Lee, Jong-Gun;Moon, Jung-Tak;Park, Jai-Hyun;Seo, Won-Chan;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.4
    • /
    • pp.65-70
    • /
    • 2008
  • The mechanical shear strength of BGA(Ball Grid Array) solder joints under high impact loading was investigated. The Sn-37Pb solder balls with a diameter of $500{\mu}m$ were placed on the pads of FR-4 substrates with ENIG(Electroless Nickel Immersion Gold) surface treatment and reflowed. For the High Temperature Storage(HTS) test, the samples were aged a constant testing temperature of $120^{\circ}C$ for up to 250h. After the HTS test, high speed shear tests with various shear speed of 0.01, 0.1, 1, 3 m/s were conducted. $Ni_3Sn_4$ intermetallic compound(IMC) layer was observed at the solder/Ni-P interface and thickness of IMC was increased with aging process. The shear strength increased with increasing shear speed. The fracture surfaces of solder joints showed various fracture modes dependent on shear speed and aging time. Fracture mode was changed from ductile fracture to brittle fracture with increasing shear speed.

  • PDF

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

SCANNING ELECTRON MICROSCOPIC STUDY ON THE EFFICACY OF ROOT CANAL WALL DEBRIDEMENT OF ROTARY NI-TI INSTRUMENTS WITH DIFFERENT CUTTING ANGLE (엔진 구동형 니켈-타이타늄 합금파일의 절삭각에 따른 근관성형 효과에 관한 전자현미경적 연구)

  • Jeon, In-Soo;Yoon, Tai-Cheol;Park, Seong-Ho;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.577-586
    • /
    • 2002
  • The purpose of this in vitro study was to compare the effects of root canal cleanness following two Ni-Ti rotary instruments with different rake angle. Thirty-six sound, extracted human premolars with single root were randomly divided into three groups. The used rotary instruments were HEROShaper (Group 1, Micro-Mega, Besancon, France, n=12) and ProFile (Group 2, Maillefer, Ballaigues, Switzerland, n=12). Control group (n=12) was only extirpated with barbed broach (Mani, Matsutani Seisakusho Co., Japan) Group 1 & 2 teeth were prepared to a #40/.04 taper at the apex followed by 1 mm using crown-down technique. After canal preparation and frequent irrigation with 5.25% sodium hypochlorite, the roots split longitudinally into a bucco-lingual direction. Root halves were cross-sectioned in apical third portion again. All root specimens were processed for SEM investigation and photographed. Separate evaluations by one endodontist were undertaken for smear layer on prepared walls with a five score-index for each using reference photograph in root halves. The penetration depth of smear layer into dentinal tubules was also estimated in the other halves. Following results were obtained: 1. Smear layer was observed on all the prepared walls with two experimental groups except control group. 2. Smear layer characteristics in two experimental groups; 1) HEROShaper group showed snowy, dusty appearance and were shown open dentinal tubuli on the prepared walls of almost specimens, and the thickness of smear layer covering onto dentinal surfaces was within 1-2 ${\mu}m$ in a few specimens. 2) ProFile group showed shiny, burnished appearance and complete root canal wall covered by a homogenous smear layer with no open dentinal tubuli in all specimens. The penetration of smear layer into dentinal tubules was found in all specimens and the thickness was at 2-4 ${\mu}m$ in all specimens. These results demonstrated that a completely clean root canal could not be achieved regardless of positive or negative rake angle, which is in accordance with the majority of previous studies on root canal cleanliness In conclusion, through irrigation with antibacterial solutions or chelating agents is recommended to remove the smear layer on prepared canal wall in spite of Ni-Ti instrumentation.

Effects of Dietary Non-Specific Immuno-Stimulator(NIS) on Growth Performance and Carcass Characteristics in Finishing Pigs (비육돈 사료내 비특이성 면역증강제(NIS)의 급여가 성장 및 도체특성에 미치는 영향)

  • 권오석;김인호;홍종욱;김지훈;민병준;이원백;손경승
    • Food Science of Animal Resources
    • /
    • v.24 no.1
    • /
    • pp.44-49
    • /
    • 2004
  • This study was conducted to evaluate the effects of non-specific immuno-stimulator(NIS) supplementation on growth performance and carcass characteristics in finishing pigs. A total of eighty[Duroc${\times}$Yorkshir${\times}$Landrace] pigs(60.55${\pm}$3.72 kg in average initial body weight) were used for a 9-week assay. Dietary treatments included as follows 1) CON(basal diet), 2) NIS1(basal diet for 6 weeks and 0.05% NIS for 3 weeks), 3) NIS2(basal diet for 3 weeks and 0.05% NIS for 6 weeks) and 4) NIS3(0.05% NIS for 9 weeks). Average daily gain during the feeding period was not significantly different among the treatments (p>0.05). However, average daily feed intake was higher in NIS2 than CON(p<0.05). Backfat thickness did not differ among the treatments(p>0.05). The appearance rate of A or B carcass grade was much higher in NIS1 (58%) and NIS3 (75%) than CON(50%) and NIS2(50%). L*(lightness) value of loin was higher in NIS1 and NIS3 than CON and NIS2. However, there was no effect by dietary NIS(p>0.05). Although a*(redness) value of loin was lower in CON than other treatments, there was no significant difference among the treatments(p>0.05). No remarkable differences were found in sensory properties(marbling, firmness and color) among the treatments. The results from the present study suggest that NIS could be an effective feed additive to improve pork quality. However, further research is needed to investigate effect of carcass characteristics.

Effects of inulin diet supplementation on production performance, gut traits, and incidence of ascites in Haidong chicks under hypoxic conditions

  • Ding, Baoan;Chen, Lingyun;Lin, Hao;Wang, Xiezhong;Zhang, Licheng;Ni, Xiaoming;Pirone, Andrea;Madigosky, Stephen R.;Fronte, Baldassare
    • Animal Bioscience
    • /
    • v.34 no.3_spc
    • /
    • pp.417-426
    • /
    • 2021
  • Objective: Effects of inulin supplementation in diet of Haidong chicks under hypoxic conditions on production performance, intestinal morphologic change, microflora contents and the incidence of ascites were studied. Methods: Commercial male chicks (360) were randomly divided into 6 groups and were fed diets supplemented with 0, 0.05, 0.075, 0.1, 0.125, and 0.15 g/kg of inulin, respectively. Results: The body weight gain and feed intake were improved in chicks fed the diets supplemented with 0.1 and 0.125 g/kg of inulin, from d 1 to d 42 (p<0.05); moreover, blood parameters were positively affected when inulin was included in the diets and the thickness of the intestinal wall and muscle tissue in duodenum, jejunum, and ileum tended to increase (p<0.05), and the villi height and crypt depth in duodenum, jejunum, and ileum (p<0.05). Regarding the number of goblet cells in duodenum, jejunum and ileum tended to increase when chicks were fed the diets supplemented with 0.075, 0.1, 0.125, and 0.15 g/kg (p<0.05) of inulin. When chicks were fed diets supplemented with 0.75 or 0.1 g/kg of inulin, a significant reduction of Escherichia coli counts in the cecum was observed; for a contrary, a significant increment of Bifidobacterium and Lactobacillus was observed in cecum and ileum. Finally, supplementing the feed with inulin determined an overall reduction of ascites incidences in comparison to the control group. Conclusion: Thus, the results observed in the present study clearly suggest that the diet supplementation with a quantity of inulin ranging between 0.1 and 0.125 g/kg, can improve growth performances, intestinal morphology, internal microbial balance and ascites incidence, in broiler chicks raised at high altitude area. Even though these findings may be of interest for the poultry industry, they may particularly be relevant in those areas characterized by high altitude such as Northwest China regions.

Effect of Post Heat Treatment on Bonding Interfaces in Ti/STS409L/Ti Cold Rolled Clad Materials (Ti/STS409L/Ti 냉연 클래드재의 접합계면특성에 미치는 후열처리의 영향)

  • Bae, D.S.;Kim, W.J.;Eom, S.C.;Park, J.H.;Lee, S.P.;Kim, M.J.;Kang, C.Y.
    • Transactions of Materials Processing
    • /
    • v.20 no.2
    • /
    • pp.140-145
    • /
    • 2011
  • The aim of the present study is to derive optimized post heat treatment temperatures to get a proper formability for Ti/STS409L/Ti clad materials. These clad materials were fabricated by cold rolling followed by a post heat treatment process for 10 minutes at temperatures ranging from $500^{\circ}C$ to $850^{\circ}C$. The microstructure of the interface was observed using a Scanning Electron Microscope(SEM) and an Energy Dispersive X-ray Analyser(EDX) in order to investigate the effects of post heat treatment on the bonding properties of the Ti/STS409L/Ti clad materials. Diffusion bonding was observed at the interfaces with a diffusion layer thickness increasing with the post heat treatment temperature. The diffusion layer was composed of a type of(${\varepsilon}+{\zeta}$) intermetallic compound containing additional elements, namely, Fe, Ti and Ni. The micro Knoop hardness of the Ti/STS409L interfaces was found to increase with heat treatment up to $800^{\circ}C$ and then decrease for temperatures rising up to $850^{\circ}C$. The tensile strength was shown to decrease for heat treatment temperature increasing to $750^{\circ}C$ and then increase rapidly for temperature rising up to $850^{\circ}C$. A post heat treatment temperature range of $700{\sim}750^{\circ}C$ was found to optimize the formability of Ti/STS409L/Ti clad materials.

Highly transparent Pt ohmic contact to InGaN/GaN blue light-emitting diodes

  • Chul Huh;Kim, Hyun-Soo;Kim, Sang-Woo;Lee, Ji-Myon;Kim, Dong-Joon;Kim, Hyun-Min;Park, Seon-Ju
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.4 no.2
    • /
    • pp.47-49
    • /
    • 2000
  • We report on the fabrication and characterization of InGaN/GaN multiple quantum well light emitting diode (LED) with a highly transparent Pt ohmic contact as a current spreading layer. The value of light transmittance of a Pt thin film with a thickness of 8 m on p-GaN was measured to be 85% at 450nm. The peak wavelength and the full-width at half-maximum (FWHM) of the emission spectrum of the LED at 20 mA were 453 m and 23 m, respectively. Pt-contacted LEDs show good electrical properties and high light-output efficiency compared to Ni/Au-contacted ones. These results suggest that a Pt thin film can be used as an effective current spreading layer with high light-transparency.

  • PDF

Hydrogeochemistry of Supply Water in the Daedeok Campus of Chungnam National University, Korea (충남대학교 대덕캠퍼스내 상수도 물의 수리지구화학적 특성)

  • 이찬희
    • Economic and Environmental Geology
    • /
    • v.33 no.3
    • /
    • pp.181-193
    • /
    • 2000
  • This study was undertaken to evaluate the drinking water quality based on physicochemical properties and chemical compositions of the supply water in the Daedeok Campus, and to verify the analytical reliabilities of ICP-MS and IC equipped in the Central Research Facilities at Chungnam National University , Korea. The supply water belongs to $Ca^{2+}-({HCO_3}^-+{SO_4}^{2-})$type, whereas the original water from the Daecheong lake belongs to $(Ca^{2+}-(Mg^{2+})-{HCO_3}^-$ type. Generally, temperature (14.1$^{\circ}C$), pH (6.95), Eh (0 mV), electrical conductivity (117${\mu}$S/cm) and TDS (86.975mg/l) of supply water were higher than those of original lake water . Results using WATEQ4F revealed that potentially toxic ions of the supply water might exist mainly as free metals ($M^{2+}$) and a small amount as ${CO_3}^{2-}$ and $OH^-$ complexes. Also, the water composition belongs to the kaolinite field. Calculated average enrichment indies of the supply water normalized to lake water for anions, mamor cations, toxic cations and total ions are 1.05 , 1.56, 13.05 and 1.17 , respectively. Those values of the ground water in the Daedeok Campus showed 1.71, 4.78, 5.71 and 2.49 , respectively. However , contents of all constituents of these water are within the drinking water standard. All samples were filtered before the chemical analysis. Pale yellow or yellowish brown colored materials of colloidal particles coated the filter paper to thickness of 0.02 to 0.2mm. these are mainly Fe-Cy-Zn compounds with traces of Ni and Pb, the net weights of which compounds range from 0.01to 3.20mg/l. Most elements did not show any conceivable filtering effect of Cu, Fe and Zn. Especially, mean concentration of total Fe decreased considerably from 168.52${\mu}g$/lto 42.58${\mu}g$/l by filtering .

  • PDF