• Title/Summary/Keyword: Newton-Raphson

Search Result 588, Processing Time 0.023 seconds

Fault Location Identification Using Software Fault Tolerance Technique (소프트웨어 Fault Tolerance를 이용한 고장점 표정)

  • Kim Wonha;Jang Yong-Won;Han Seung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.2
    • /
    • pp.73-78
    • /
    • 2005
  • The management of technological systems will become increasingly complex. Safe and reliable software operation is a significant requirement for many types of system. So, with software fault tolerance, we want to prevent failures by tolerating faults whose occurrences are known when errors are detected. This paper presents a fault location algorithm for single-phase-to-ground faults on the teed circuit of a parallel transmission line using software fault tolerance technique. To find the fault location of transmission line, we have to solve the 3rd order transmission line equation. A significant improvement in the identification of the fault location was accomplished using the N-Version Programming (NVP) design paradigm. The delivered new algorithm has been tested with the simulation data obtained from the versatile EMTP simulator.

Low-Frequency Harmonic Eliminations on DC/AC Sides of a 3 Phase-Controlled Converter (3상 제어컨버터의 노치법에 의한 출력과 입출력의 저고조파 제거)

  • 홍성태;권순결;이현우;서기영;임근희
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.906-915
    • /
    • 1994
  • Line-Current harmonics resulting from ac to dc power conversion interfere with power system operation and reduce power factor, hence resulting in increasing power source unnecessarily. This study describes a 3 phase phase-controlled converter eliminating low frequency harmonics in the output by inserting notches. Notch points are calculated by Newton-raphson method, The impacts of the choppings on ac and dc sides are analyzed in the steady state. Potential applications of the study are dc motor controls, high power dc power supplies for telecommunications, static var compensators and HVDC.

  • PDF

New Power Flow Calculation Using Improved Genetic Algorithm (개선된 유전 알고리즘을 이용한 새로운 전력조류계산)

  • Chae, Myung-Suck;Lee, Tae-Hyung;Shin, Joong-Rin;Im, Han-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.43-51
    • /
    • 1999
  • The power flow calculations(PFc) are the most important and powerful tools in power systems engineering. The conventional power flow problem is solved generally with numerical methods such as Newton-Raphson(NR). The conventional numerical method generally have some convergency problem, which is sensitive to initial value, and numerical stability problem concerned with jacobian matrix inversion. This paper presents a new PFc algorithm based on the improved genetic algorithm (IGA) which can overcome the disadvantages mentioned above. The parameters of GA, with dynamical hierarchy of the coding system, are improved to make GA a practical algorithm in the problem of real system. Some case studies with test bus system also present to show the performance of proposed algorithm. The results of proposed algorithm are compared with the results of PFc obtained using a conventional NR method.

  • PDF

Three-phase Load Flow using DistFlow Method (DistFlow Method를 이용한 삼상조류해석 알고리즘에 관한 연구)

  • Kwak, Do-Il;Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.43-45
    • /
    • 2000
  • Traditionally, load flows have been calculated using the Gauss-Seidel and Newton-Raphson Method. DistFlow Method which is proposed by Wu and Baran is superior to the other two methods because it does not require the admittance matrix calculation to optimize the distribution system. This paper introduces a new alternative algorithm to the DistFlow Method which is slow and complex to find solutions as the number of lateral and sublateral increases. The proposed load flow method can construct System Jacobian easily. We can minimize the off-diagonal elements of the branch Jacobian and submatrices in the System Jacobian. Simulation results show that progressive performances of the proposed algorithm.

  • PDF

The Improvement of Continuation Power Flow System Using Decoupled Method (Decoupled법을 이용한 연속조류계산 시스템의 개발)

  • Park, Min-Seok;Song, Hwa-Chang;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.46-48
    • /
    • 2000
  • Continuation power flow has been developed to remove the ill-condition problem caused by singularity of power flow Jacobian at and near steady-state voltage instability point in conventional power flow. When solving large-scale power transmission systems, an alternative strategy for improving computational efficiency and reducing computer storage requirements is the decoupled power flow method, which makes use of an approximate version of the Newton-Raphson procedure. This paper presents a technique to improve the speed of continuation power flow system using decoupled power flow method.

  • PDF

Estimation of Power System Parameters using Synchronized Phaser Measurements (동기 페이저 측정치를 이용한 전력계통 매개변수 추정)

  • Song, Shi-Cheol;Cho, Ki-Seon;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.80-84
    • /
    • 2000
  • Network parameters in power systems are indispensable for all of power system engineering studies, including the power flow calculation and the state estimation. The network parameters required for the studios, in general, are estimated by using several estimation techniques, since it Is very difficult to measure. To improve the estimation accuracy of the network parameters, this paper adopt the synchronized phasor measurements which are acquired from the Phasor Measurement Unit with built-in GPS receiver. In this paper, the parameter estimation problem is formulated with over-determined nonlinear measurement equations and solved with Newton-Raphson method and pseudo-inverse. The effectiveness of the proposed parameter estimation with the synchronized phasor measurements is verified through some case studies with IEEE sample system. The results are very promising.

  • PDF

Application of Procedures to Calculate Thermodynamic Properties of Carbon Dioxide, HFC-134a and HCFC-22

  • Park Hyoung Joon;Park Kyoung Kuhn
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.176-183
    • /
    • 2004
  • Systematic methods to calculate thermodynamic properties of carbon dioxide, HFC-134a and HCFC-22 are presented. First, application of a basic method to identify the saturation state with given temperature or pressure is attempted and the feasibility of auxil­iary equations is tested. Next, detailed procedures are suggested to tell a phase when tem­perature/pressure and another property are specified. Finally the Newton-Raphson method is applied to calculate unknown thermodynamic properties fixing the state with the two inde­pendent properties specified. The procedures described here are utilized to develop a computer program, which is used to find the relation between temperature and pressure with maximum isobaric heat capacity for super-critical carbon dioxide.

Minimum Disparity Estimation for Normal Models: Small Sample Efficiency

  • Cho M. J.;Hong C. S.;Jeong D. B.
    • Communications for Statistical Applications and Methods
    • /
    • v.12 no.1
    • /
    • pp.149-167
    • /
    • 2005
  • The minimum disparity estimators introduced by Lindsay and Basu (1994) are studied empirically. An extensive simulation in this paper provides a location estimate of the small sample and supplies empirical evidence of the estimator performance for the univariate contaminated normal model. Empirical results show that the minimum generalized negative exponential disparity estimator (MGNEDE) obtains high efficiency for small sample sizes and dominates the maximum likelihood estimator (MLE) and the minimum blended weight Hellinger distance estimator (MBWHDE) with respect to efficiency at the contaminated model.

Determination Algorithm of Hydraulic Parameters in Water Distribution System (상수관망의 수리학적 지배인자 결정기법)

  • Park, Jae-Hong;Kim, Sang-Hyun;Han, Kun-Yeun
    • Water for future
    • /
    • v.29 no.6
    • /
    • pp.217-224
    • /
    • 1996
  • In this paper, the evaluation of diameter, global velocity, global roughness coefficients of the water distribution pipes are examined by using pressure and flowrate measurements in selected points of the network. The selected pipe network parameters are determined through reformulation of the continuity and energy equation. Additional energy equation is considered to analyze the coefficient matrix. The resulting nonlinear equations are solved by using Newton Raphson method. Three computer models with complex pipe system are used to demonstrate these procedures. The computed results of hydraulic parameters show good agreements with KYPIPE2 flow analysis model.

  • PDF

Hydrodynamic Analysis of Piston Rings (피스톤 링의 유체 윤활 해석)

  • 김재현;최상민;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.167-172
    • /
    • 1998
  • An algorithm of Thermal-elastohydrodynamic lubrication analysis for the piston ring is developed. This algorithm contains cavitation boundary condition so it automatically satisfies conservation of mass. 1-D Reynolds equation and 2-D energy equation are solved simultaneously by using Gauss-Jordan method and Newton-Raphson method. Minimum film thickness and friction force are calculated for 1 cycle. There is little difference between the results caculated by isothermal rigid and EHL analysis in entire cycle. In the results of THL, shear heating effect and temperature boundary condition affect the minimum film thickness and friction force prediction. The minimum film thickness and the friction force calculated by THL are lower than those caculated using isothermal assumption.

  • PDF