• Title/Summary/Keyword: New type section

Search Result 303, Processing Time 0.026 seconds

Seismic behavior of steel reinforced concrete (SRC) joints with new-type section steel under cyclic loading

  • Wang, Qiuwei;Shi, Qingxuan;Tian, Hehe
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1561-1580
    • /
    • 2015
  • No significant improvement has been observed on the seismic performance of the ordinary steel reinforced concrete (SRC) columns compared with the reinforced concrete (RC) columns mainly because I, H or core cross-shaped steel cannot provide sufficient confinement for core concrete. Two improved SRC columns by constructing with new-type section steel were put forward on this background: a cross-shaped steel whose flanges are in contact with concrete cover by extending the geometry of webs, and a rotated cross-shaped steel whose webs coincide with diagonal line of the column's section. The advantages of new-type SRC columns have been proved theoretically and experimentally, while construction measures and seismic behavior remain unclear when the new-type columns are joined onto SRC beams. Seismic behavior of SRC joints with new-type section steel were experimentally investigated by testing 5 specimens subjected to low reversed cyclic loading, mainly including the failure patterns, hysteretic loops, skeleton curves, energy dissipation capacity, strength and stiffness degradation and ductility. Effects of steel shape, load angel and construction measures on seismic behavior of joints were also analyzed. The test results indicate that the new-type joints display shear failure pattern under seismic loading, and steel and concrete of core region could bear larger load and tend to be stable although the specimens are close to failure. The hysteretic curves of new-type joints are plumper whose equivalent viscous damping coefficients and ductility factors are over 0.38 and 3.2 respectively, and this illustrates the energy dissipation capacity and deformation ability of new-type SRC joints are better than that of ordinary ones with shear failure. Bearing capacity and ductility of new-type joints are superior when the diagonal cross-shaped steel is contained and beams are orthogonal to columns, and the two construction measures proposed have little effect on the seismic behavior of joints.

Girder Section of Continuous Bridges Spliced by Partial Post-Tensioning (부분 포스트텐션닝 방법에 의해 연속화된 교량의 주형단면)

  • 이환우;곽효경;송영용
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.43-50
    • /
    • 2000
  • In this paper, a new splicing method was applied to design the girder section of bridges with the span length of 25m, 30m, 35m, 40m and 45m. A U-type precast prestressed section was also determined for each bridge. Additionally, the sectional area, beam depth and Guyon's efficiency factor of the spliced U-type sections in each span were analyzed in comparison with the present I-type PSC bridges. As a result, in spite of an increase of 31%∼50% in the sectional areas compared with the I-type precast girders, the spliced U-type the beam depth of the spliced U-type girder was designed as 2,050 mm compared with the I-type precast girder of 2,600mm in a 40m span bridge. The sectional efficiency factors of the spliced U-type sections were analyzed as 0.76∼0.99. It shows that the spliced U-type sections ar of a superior structural efficiency in contrast to the average sectional efficiency factor of 0.66 value in the I-type girders.

A Numerical Study on Inplane Nonlinear Buckling Strengths of New Arches Subjected to Uniformly Distributed Loading (수직등분포하중을 받는 신형식단면 원형아치리브의 비선형 면내좌굴강도에 대한 해석연구)

  • Park, Jong-Sup;Kang, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.399-405
    • /
    • 2012
  • This paper investigates the characteristics of buckling loads for steel arches with new type cross section which is consisted of T-section and pipe-section. A general purpose finite-element program ABAQUS was used to evaluate the inelastic buckling strengths of the arches which included the influence of the geometric and material nonlinearity. According to the comparisons between earlier studies and results from finite-element analyses, new design equations should be developed for the new arches. New buckling factors were developed to consider influence of rise-to-span ratio and boundary conditions. It is found that the presented factors are sufficiently accurate to predict the inplane buckling loads of new type section steel arches subjected to uniformly distributed loading. The proposed equations can be used to investigate new type steel arches subjected to unsymmetrical loading and composited arches.

A Comparative Analysis of Existing Channel-Type Lining Board and New-Type lining Board Models (기존 채널형 복공판과 새로운 복공판 모델에 관한 비교분석 연구)

  • Kim Doo-Hwan;Kim Young-Sei
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.78-83
    • /
    • 2004
  • The channel-type lining board that partial welded on many partition frames is used to normal servicing lining board type. On this study is to investigate existing channel-type lining board's capacity by using the static loading test. From this study, to develop new-type lining board which reflect well cross section area and sectional modulus of existing channel-type lining board. Six types FEM model are adopted. The accumulated test results of stress conditions and deflections by section shapes will be used to analyzed the relation between the capacity and the section shape. With the comparing the results of static loading test and FEM analysis.

A Study on Optimum Section of New Type Steel-Concrete Composite Beam (신형상 층고절감형 합성보의 최적단면 도출에 관한 연구)

  • Yoon, Myung-Ho;Lee, Yoon-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.30-35
    • /
    • 2011
  • This study investigates the optimum section properties of newly developed steel-concrete composite beam. For that purpose we developed computer program calculating section properties. The suggested new beam section highly contribute to save inter-story height and reduce construction duration and cost compared with conventional steel works such as H-beam and column + RC slab system. But the section shape have different section modulus with upper and lower fiber because of the unsymmetric cross section. Therefore the parametric study on thickness-ratio of top and bottom flange plate is needed. In this paper the change of neutral axis and section modulus for thickness-ratio of up and down flage plate is analysed and discussed.

A Study on the Section Design of FRP-Concrete Composite Slabs Considering Failure Behaviors (파괴 거동을 고려한 FRP-콘크리트 합성 바닥판의 단면 설계에 관한 연구)

  • 조근희;김병석;이영호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.641-646
    • /
    • 2002
  • FRP-concrete composite slab is consisted of brittle materials and then shows brittle failure mechanism. This study suggests a new design approach that FRP-concrete composite slab leads to ductile failure, and investigates their failure behaviors for two types of section by numerical analysis. Box-type section is higher than I-type section in load capacity to required FRP quantity. Each section was designed so that the strain of FRP plate is 50% to its ultimate strain on initiation of concrete crushing, and it is verified that displacement ductility is more than two. Ductility capacity can be improved by reducing the strain of FRP on initiation of concrete crushing, but as the strain of FRP is reduced load capacity to required FRP quantity is also reduced. Therefore section optimization study is needed considering safety and economical efficiency.

  • PDF

Buckling Behavior of Plates Stiffened with the New Type Ribs (새로운 형태의 리브를 갖는 보강판의 좌굴거동)

  • Chu, Seok Beom;Lee, Pil Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.1
    • /
    • pp.59-66
    • /
    • 2018
  • In this study, the parametric analysis for the buckling behavior of plates stiffened with the new type(${\Box}$ type) ribs was performed. Changes of the buckling capacity according to dimensions of ${\Box}$ type ribs show certain behaviors, so that the system to find the section of ${\Box}$ type ribs under the specific buckling capacity can be proposed. Applying this system to the steel deck of existing bridges, more economic sections of ${\Box}$ type ribs rather than that of closed ribs can be obtained. Therefore, the economic section of steel deck having the required buckling capacity can be designed by using the proposed system of ${\Box}$ type ribs.

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

A Study on the Safety of Passing-type Climbing Lanes in Expressways using C-G Method (비교그룹방법을 이용한 고속도로 추월차로형 오르막차로 안전성 연구)

  • Kim, Bong Soo;Kim, Sang-Gu;Yun, Ilsoo;Oh, Young-Tae;Hong, Doo-Pyo;Lee, Kang-Hoon
    • International Journal of Highway Engineering
    • /
    • v.16 no.1
    • /
    • pp.99-109
    • /
    • 2014
  • PURPOSES : Climbing lanes on expressways managed by the Korea Expressway Corporation (KEC) have been hot potatoes due to conflicts between slow-moving vehicles such as trucks and other vehicles at the merging section as well as the less popularity with the slow-moving vehicles. In order to resolve such problems, KEC has altered existing climbing lanes to passing-type climbing lanes in 1999. The new type of climbing lanes showed an apparent improvement in mobility. For example, the speeds of vehicles using both climbing lane and other lanes improved a lot. However, there has been no clear evidence about improved safety. METHODS : This research effort was initiated to evaluate the safety of the new passing-type climbing lanes using the comparison-group(CG) method based on three-year-long traffic accident data sets before and after the change, respectively. RESULTS : The passing-type climbing lanes showed twice increased traffic accidents even though the traffic accidents on old type climbing lanes increased 1.1% during the same periods. In addition, in-depth study, the merging area of the passing-type climbing lanes was found out to be the weakest section where 43.8% traffic accidents out of total traffic accidents happened. It is noted that the merging area of the old type climbing showed only 25.0% traffic accidents. CONCLUSIONS : The new passing-type climbing lanes were found to be weak in terms of safety when compared with the old type climbing lanes. Especially, the merging area should be improved to reduce the risk of traffic conflicts between slow-moving vehicles and other vehicles.

A Study on the Design Parameters of the PSC I-Type Girders for Long Span Bridges (장지간 교량을 위한 PSC-I형 거더의 단면 설계변수 연구)

  • 심종성;오홍섭;김민수
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.13-22
    • /
    • 2000
  • In order to resolve the problem of increasing traffic entailed by the economic development, road system is reorganization and new highways are built, and long span bridges over 40m are being constructed in environmental and aesthetic considerations. Most long span bridges that are currently being constructed are in general steel box girder and preflex girder bridges; however these types of breiges are less efficiency than PSC I-type girder bridges in terms of construction cost and maintenance. Therefore, in these study, structural efficiency of PSC I-type girders based on section parameters, concrete compressive strength and other design parameter is observed to develope new PSC I-type girder for long span bridges. As a results of analysis, most important design parameters that control the stress of the girder are found to be the top flange width and the height of girder. In this light, the relationship between the two variables is determined and cross-section details of the girder that most appropriates for the long span bridges are proposed. The use of high strength concrete appears to increase the general design span however the increase rate of the span from increasing concrete ultimate strength appears to be reduced depending on the span. Also, the optimal girder spacing is determined through the parameter studies of design span using the proposed girder.