• 제목/요약/키워드: New technology

검색결과 30,067건 처리시간 0.055초

Hydrothermal Synthesis, Crystal Structures and Properties of Zinc(II) Di-nuclear Complex and Copper(I) Coordination Polymer Based on Building Block 2-Phenyl-4,6-di(pyridin-2-yl)pyrimidine

  • Zhao, Pusu;Jing, Wang;Jing, Long;Jian, Fangfang;Li, Yufeng
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3743-3748
    • /
    • 2013
  • A tetradentate ligand of 2-phenyl-4,6-di(pyridin-2-yl)pyrimidine (L) has been synthesized and its complexes with $ZnI_2$ and CuI have been obtained by hydrothermal method. single crystal X-ray diffraction analysis indicates that ligand L coordinates with Zn(II) ions to form a simple four-coordinate di-nuclear complex, while the complexation of L with Cu(I) constructs a one-dimensional chain polymer. The existence of $I^-$ ion hampers the L to assemble grid-type complexes with Zn(II) and Cu(I). Fluorescence spectra show that the L emits blue fluorescence while its Cu(I) polymer decrease the fluorescence intensity and Zn(II) complex quenches the fluorescence.

Energy Star 기준에 따른 Omnidirectional LED 벌브의 전기적 광학적 특성 분석 (Analysis of the Electrical and Optical Properties in Omnidirectional LED Bulbs by Energy Star)

  • 김유신;배호준;김기훈;김현식;송상빈
    • 한국전기전자재료학회논문지
    • /
    • 제25권9호
    • /
    • pp.750-754
    • /
    • 2012
  • An LED (light emitting diode) has the advantages of lower power consumption, energy saving, high efficiency, long lifetime, and environmental friendliness so that it has been getting the spotlight as a next-generation light source. Thus, the application range of an LED has been extended to various fields including indoor and outdoor lighting. Recently, the high efficient LED lighting has been developed, an LED has been extended its market rapidly every year and is expected to replace the general light source within near future. In this study were measured electrical and optical properties for 6 types of LED bulbs which are being developed to replace the general incandescent lamps, and were analysed under the standard of the omnidirectional lamp required by the Energy Star.

Cytotoxic Components in an Extract from the Leaves and Stems of Stauntonia hexaphylla

  • Zhao, Jing;Yim, Soon-Ho;Um, Jung-In;Park, Si-Hwan;Oh, Eun-Sang;Jung, Da-Woon;Williams, Darren R.;Lee, Ik-Soo
    • Natural Product Sciences
    • /
    • 제20권2호
    • /
    • pp.130-134
    • /
    • 2014
  • An investigation was carried out to identify novel anti-cancer compounds from Korean indigenous plant extracts. Bioassay-guided fractionation and chemical investigation of the EtOAc extract from the leaves and stems of Stauntonia hexaphylla resulted in the isolation of two active compounds, hederagenin 3-O-${\alpha}$-L-arabinoside (1) and quercetin (2). The structures of these compounds were elucidated by spectroscopic methods, including UV, IR, MS, NMR techniques and compared with previous spectroscopic data. The cytotoxic effects of fractions and compounds on HCT116 human colon cancer cells were evaluated using the MTT assay. Quercetin showed a stronger anti-cancer effect when compared to hederagenin 3-O-${\alpha}$-L-arabinoside.

Multi Channel LED 조명 Module 구동에서 최대 효율을 위한 최대 Channel 전압 감지회로 (Feedback Circuit of Maximum LED Channel String Voltage Detection Converter for Energy Saving on Multichannel LED Module)

  • 김현식;김기원;김기훈;김유신;송상빈
    • 한국전기전자재료학회논문지
    • /
    • 제25권11호
    • /
    • pp.938-941
    • /
    • 2012
  • LED is divided to multichannel in order not to exceed a certain voltage in aspects of electric standard. However, it's not possible to know in accordance with what channel SMPS controls the constant voltage and current. In order to solve this problem, it needs to detect the maximum LED String voltage which is applied to LED control circuit, and it is possible to minimize the voltage drop when a difference of LED string voltage occurs by each channel if LED is controlled by the maximum LED string voltage detected. In addition, it is also possible to maximize the efficiency of LED if change LED voltage by detecting the maximum voltage. Feasibility of this claim was verified through implementation of the circuit.

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.

  • PDF

A semi-analytical mesh-free method for 3D free vibration analysis of bi-directional FGP circular structures subjected to temperature variation

  • Shamshirsaz, Mahnaz;Sharafi, Shahin;Rahmatian, Javad;Rahmatian, Sajad;Sepehry, Naserodin
    • Structural Engineering and Mechanics
    • /
    • 제73권4호
    • /
    • pp.407-426
    • /
    • 2020
  • In this present paper, a semi-analytical mesh-free method is employed for the three-dimensional free vibration analysis of a bi-directional functionally graded piezoelectric circular structure. The dependent variables have been expanded by Fourier series with respect to the circumferential direction and have been discretized through radial and axial directions based on the mesh-free shape function. The current approach has a distinct advantage. The nonlinear Green-Lagrange strain is employed as the relationship between strain and displacement fields to observe thermal impacts in stiffness matrices. Nevertheless, high order terms have been neglected at the final steps of equations driving. The material properties are assumed to vary continuously in both radial and axial directions simultaneously in accordance with a power law distribution. The convergence and validation studies are conducted by comparing our proposed solution with available published results to investigate the accuracy and efficiency of our approach. After the validation study, a parametric study is undertaken to investigate the temperature effects, different types of polarization, mechanical and electric boundary conditions and geometry parameters of structures on the natural frequencies of functionally graded piezoelectric circular structures.

슁글드 모듈에서 경화조건에 따른 ECA 접합강도와 효율의 상관관계에 관한 연구 (A Study on Correlation Peel Strength and the Efficiency of Shingled Modules According to Curing Condition of Electrically Conductive Adhesives)

  • 전다영;손형진;문지연;조성현;김성현
    • Current Photovoltaic Research
    • /
    • 제9권2호
    • /
    • pp.31-35
    • /
    • 2021
  • Shingled module shows high ratio active area per total area due to more efficient packing without inactive space between cells. The module is fabricated by connecting the pre-cut cells into the string using electrically conductive adhesives (ECA). ECAs are used for electric and structural connections to fabricate the shingled modules. In this work, we investigated a correlation between ECA peel strength and the efficiency of pre-cut 5 cells module which are fabricated according to ECA interconnection conditions. The curing conditions are varied to determine whether ECA interconnection properties can affect module properties. As a result of the peel test, the highest peel strength was 1.27 N/mm in the condition of 170℃, the lowest peel strength was 0.89 N/mm in the condition of 130℃. The efficiency was almost constant regardless of the curing conditions at an average of 20%. However, the standard deviation of the fill factor increased as the adhesive strength decreased.

기업의 기술개발전략이 성과에 미치는 영향에 관한 연구 (The relation between technology acquisition strategies and corporate performances)

  • 노정구
    • 경영과정보연구
    • /
    • 제18권
    • /
    • pp.69-90
    • /
    • 2006
  • In this empirical study, we try to find major factors influencing the selection of technology acquisition strategy, and to examine the relation between technology acquisition strategies and corporate performances. The results of this study are as follows. Firstly, it is required to make intrinsic efforts for the harmony of technology acquisition strategies, which guarantees the effective acquirement of new technology. Secondly, we should pay particular attention to the harmony of external and internal resources for the corporate growth, Finally, the development of new technology is to be made on the basis of technology acquisition strategy established in terms of resources.

  • PDF

A modified JFNK with line search method for solving k-eigenvalue neutronics problems with thermal-hydraulics feedback

  • Lixun Liu;Han Zhang;Yingjie Wu;Baokun Liu;Jiong Guo;Fu Li
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.310-323
    • /
    • 2023
  • The k-eigenvalue neutronics/thermal-hydraulics coupling calculation is a key issue for reactor design and analysis. Jacobian-free Newton-Krylov (JFNK) method, featured with super-linear convergence rate and high efficiency, has been attracting more and more attention to solve the multi-physics coupling problem. However, it may converge to the high-order eigenmode because of the multiple solutions nature of the k-eigenvalue form of multi-physics coupling issue. Based on our previous work, a modified JFNK with a line search method is proposed in this work, which can find the fundamental eigenmode together with thermal-hydraulics feedback in a wide range of initial values. In detail, the existing modified JFNK method is combined with the line search strategy, so that the intermediate iterative solution can avoid a sudden divergence and be adjusted into a convergence basin smoothly. Two simplified 2-D homogeneous reactor models, a PWR model, and an HTR model, are utilized to evaluate the performance of the newly proposed JFNK method. The results show that the performance of this proposed JFNK is more robust than the existing JFNK-based methods.