• Title/Summary/Keyword: New renewable energy system

Search Result 1,388, Processing Time 0.03 seconds

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

Green Energy Technology Commercialization Promotion Methods using Smart Green Certification System and Regional Cooperation Network Construction (스마트 녹색인증 시스템 및 지역별 협력네트워크 구축을 통한 그린에너지 기술사업화 활성화 방안)

  • Ryu, Se-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.140-140
    • /
    • 2010
  • 최근 정부가 저탄소 녹색성장을 새로운 국정비전으로 제시하고 혁신적 그린에너지 기술개발을 위해 연평균 20%이상의 R&D 예산을 증액하고 있는 상황에서 연구개발결과의 상용화율 제고를 위한 연구기획, 평가, 관리시스템의 개선이 시급한 실정이다. 특히 선진국의 경우 최근 3년간 에너지분야 R&D의 상용화율이 미국 35.9%, 유럽 46.8%로서 24.2%인 한국에 비해 매우 높다고 할 수 있다. 이와같은 격차가 존재하는 것에 대해서 다양한 요인을 생각해볼 수 있겠지만, 크게 시장적인 또는 산업적인 측면에서의 중요도를 기준으로 연구과제를 선정하지 못하고 있다는 점과 연구개발결과를 효율적으로 사업화하고 있지 못하고 있다는 점을 생각해볼 수 있다. 특히 에너지 분야는 대규모 자금의 초기소요 및 개발기술 상용화기간의 장기화등으로 인해 사업화 실적이 타산업대비 매우 저조한 편이다. 이와같은 연구결과의 사업화와 관련된 문제점을 극복하기 위한 노력으로 국내에서 다양한 형태의 기술사업화 지원프로그램이 운영괴고 있으나, 에너지 분야에 특화된 프로그램은 부족한 상황이다. 반면에 미국의 경우, 재생에너지 R&D분야 전문투자자 그룹인 클린테크그룹 등을 중심으로 2002년부터 현재까지 다수의 녹색기술분야에 특화된 기술사업화 지원 프로그램을 운영하고 있다. 그 결과 현재까지 약 9년간 총 16억$의 투자유치에 성공함으로써 민간투자 활성화 역할을 담당하고 있다. 따라서 국내의 경우에도 이와같은 에너지 R&D 결과를 효과적으로 사업화로 연계시킬 수 있는 관련 프로그램 등이 시급히 도입되어야 할 것이다. 본 논문에서는 국내의 사업화 부진문제를 해결하기 위한 하나의 방안으로서 올해부터 정부주관으로 시행되고 있는 녹색인증사업을 활용하여 사업화가 유망한 기술 및 기업을 선별하고, 이에 대해 사업화 지원을 위한 후속프로그램을 적극 지원함으로써 연구개발결과의 경제적 활용도를 획기적으로 개선하는 방안을 제시하고자 한다. 또한 사업화 지원프로그램의 효율성을 높이기 위해 수도권, 영남권, 호남권 등 지역별 TP 등을 중심으로 기술사업화 협력 네트워크를 구축하고, 이를 기반으로 한 수요기술조사, 기술마케팅, 투자자유치 등의 관련프로그램을 개발하여 전단의 시스템과 융합시킴으로써 향후의 정부주도 R&D결과의 상용화율을 제고할 수 있는 시스템을 제안하고자 한다. 이에는 에너지 R&D분야별 기술적 시장적 특징분석, 지역별 산업특성과 기술공급 서플라이 체인분석을 토대로 한 기술이전 잠재수요기업 투자자를 대상으로 한 맞춤형 기술사업화 프로그램 등이 포함된다. 마지막으로 제안된 시스템에 대한 타당성 검증을 위해 올해년도에 시행한 녹색인증 기술사업화 연계프로그램 및 기술사업화 협력네트워크 활용사례 등을 분석하고, 향후 발전방향으로서 기술사업화 유관기관간간 기술사업화 정보교환 및 사업화 유망기술 기업 마케팅 등을 기본내용으로 한 시장지향적 녹색에너지 R&D 관리 시스템 구축방안을 제시하고자 한다.

  • PDF

Floating Photovoltaic Plant Location Analysis using GIS (GIS를 활용한 수상 태양광 발전소 입지 분석)

  • Lee, Ki Rim;Lee, Won Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.51-59
    • /
    • 2016
  • Global consumption of fossil fuels continues to increase. As developing countries use fossil fuel as much as the existing fossil fuel using countries, the total amount of fossil fuel consumed has risen. The finite fossil energy depletion insecurity have become serious. In addition, fossil energy is caused by environmental pollution, economic and social problems remain in assignments that need to be addressed. Although solar power is clean and has many benefits, there are several problems in the process of installing a solar power plant. To solve these problems, floating photovoltaic plants has emerged as an alternative. This floating photovoltaic plants location analysis has not been made yet. In this study, the conditions of the floating photovoltaic plants location is analyzed with the Analytic Hierarchy Process using the terrain and climate factors. The score is assigned to the attribute information of each factor by the classification table. After multiplied by the weight the result is analyzed by visualization of the score. As the result, the score of the northen part of Gyeongsangbuk-do province is higher than the southern part of Gyeongsangbuk-do province. Especially Andongho lake in Andong City and the reservoir in Yeongyang-Gun are extracted as the optimal location. The score of the river boundary is low not the center of the river stream. It is expected that this study would be a more accurate floating solar power plant location analysis.

A Study on the Analysis of Safety Standard and Evaluation of Safety Performance for the 5 Nm3 /hr Class Alkaline Water Electrolysis System (5 Nm3 /hr급 알카라인 수전해 시스템 안전기준 분석 및 안전성능 평가에 관한 연구)

  • Kim, Ji-Hye;Lee, Eun-Kyung;Kim, Min-Woo;Oh, Gun-Woo;Lee, Jung-Woon;Kim, Woo-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.65-75
    • /
    • 2018
  • The wind energy produced at night is being discarded because of the excess power generated at night compared to daytime. To solve this problem, In this study, we analyzed the evaluation contents for evaluation of domestic and overseas water electrolysis systems and drew contents for safety performance contents test of the water electrolysis system based on the evaluation contents. The test contents produced the efficiency measurement test, the hydrogen generated pressure test, and the hydrogen purity test. And the safety performance evaluation of the alkaline water electrolysis system of $5Nm^3/hr$ was performed based on the results. As a result, the hydrogen generation was calculated as $5.10Nm^3/hr$ and the stack efficiency was $4.97kWh/Nm^3$. The purity of the hydrogen generated was 99.993% and it was confirmed that it produced high purity hydrogen. I think will help us assess and build safety performance of water electrolysis systems in the future.

Cost Estimation Model for Introduction to Virtual Power Plants in Korea (국내 가상발전소 도입을 위한 비용 추정 모델)

  • Park, Hye-Yeon;Park, Sang-Yoon;Son, Sung-Yong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.178-188
    • /
    • 2022
  • The introduction of virtual power plants is actively being discussed to solve the problem of grid acceptability caused by the spread of distributed renewable energy, which is the key to achieving carbon neutrality. However, a new business such as virtual power plants is difficult to secure economic feasibility at the initial stage of introduction because it is common that there is no compensation mechanism. Therefore, appropriate support including subsidy is required at the early stage. But, it is generally difficult to obtain the cost model to determine the subsidy level because of the lack of enough data for the new business model. In this study, a survey of domestic experts on the requirements, appropriate scale, and cost required for the introduction of virtual power plants is conducted. First, resource composition scenarios are designed from the survey results to consider the impact of the resource composition on the cost. Then, the cost estimation model is obtained using the individual cost estimation data for their resource compositions using logistic regression analysis. In the case study, appropriate initial subsidy levels are analyzed and compared for the virtual power plants on the scale of 20-500MW. The results show that mid-to-large resource composition cases show 29-51% lower cost than small-to-large resource composition cases.

Evaluation of the Waste Gasification System Using Analysis Framework for Gasification System (가스화시스템 분석 프레임워크를 이용한 폐기물 가스화 시스템 분석.평가)

  • Kim, NaRang;Gu, JaeHoi;Kim, SuHyun;Park, SooNam;Sung, HoJin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.209.2-209.2
    • /
    • 2010
  • 최근 정부의 녹색성장 정책, 고유가시대 도래, 온실가스 감축 의무화, 폐기물 해양배출 강화 등으로 인해 폐기물의 자원화에 대한 관심이 고조되고 있다. 국내에서 발생되는 가연성폐기물을 기존의 감량처리 대신 가스화 공정을 적용하여 합성가스로 전환할 경우 환경친화적이고 고효율의 에너지 회수가 가능하게 된다. 폐기물 가스화를 통해 얻어진 합성가스는 난방, 가스엔진 및 연료전지를 이용한 전기생산과 DME, SNG등의 합성연료유 제조에 활용될 수 있으며, WGS 반응 및 PSA 방법에 의해 수소를 얻을 수 있다. 이와 더불어 최근에는 메탄올과 CO의 합성을 통해 얻어지는 초산제조 공정에서의 원료로서 폐기물 가스화를 통한 합성가스 내의 CO를 활용하는 방안이 연구되고 있다. 이는 기존 초산 제조공정에서 CO를 생산하기 위해 소모되는 고가의 석유계(납사, 중질유) 원료를 절감할 수 있어 경제적으로 장점을 가지고 있다. 이를 위해서는 폐기물 가스화에서 발생된 합성가스 내에 포함된 금속성분, 분진등의 오염물질의 농도가 후단공정에 영향을 주지 않아야 하며, 초산제조공정의 안정적인 운전을 위해 합성가스의 CO, $H_2$ 조성 변화폭이 ${\pm}5%$이하로 유지되어야 하는 기술적인 문제를 해결해야 한다. 따라서 본 연구에서는 폐기물 가스화 시스템의 운전특성을 통해 환경성, 기술성, 경제성을 분석 평가 할 수 있도록 구성된 분석 프레임워크를 이용하여, 초산제조공정에 적용하기위한 상용급 폐기물 가스화 시스템의 특성을 비교 분석하였다.

  • PDF

High Pressure Operation Characteristics of Pilot Scale Entrained-Bed Gasification System Using ABK Coal (ABK탄을 이용한 pilot급 분류층 석탄가스화기 시스템의 고압 운전특성)

  • Chung, Seokwoo;Yoo, Sangoh;Jung, Woohyun;Lee, Seungjong;Yun, Yongseung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.105.2-105.2
    • /
    • 2010
  • 석탄의 직접 연소 대신 고온/고압의 조건에서 불완전연소 및 가스화 반응을 통하여 일산화탄소(CO)와 수소($H_2$)가 주성분인 합성가스를 제조하여 이용하는 석탄 가스화 기술은 현실적인 에너지원의 확보를 위한 방법인 동시에 이산화탄소를 저감할 수 있는 기술이라 할 수 있다. 따라서, 본 연구에서는 non-slagging 방식의 pilot급 분류층 석탄가스화기를 대상으로 고압 미분탄공급장치, 합성가스 냉각장치, 고온 집진장치 등을 연계하여 상용급 석탄가스기와 유사한 $1,300^{\circ}C$, 20 kg/$cm^2$의 운전조건에서 미분탄의 안정적인 공급을 통한 양질의 합성가스 제조 및 제조된 합성가스의 분기 공급특성 시험을 진행하였다. 그리고, 고압 미분탄공급장치는 공급호퍼에 저장된 미분탄을 고온/고압 조건으로 운전되는 석탄가스화기에 공급하기 위한 설비로서, 이러한 고압 미분탄공급장치를 이용한 기류수송 방식의 미분탄 공급 기술은 가스화기 설계 및 운전제어 기술과 더불어 석탄가스화기 시스템의 안정적 연속운전을 위한 가장 핵심적인 기술 중 하나라고 할 수 있다. 따라서, 본 연구에서는 아역청탄인 인도네시아 ABK탄을 대상으로 향후 dense phase 고압 기류수송을 목적으로 하는 고압 미분탄공급장치의 성능특성을 시험을 진행하였는데, 시험 결과 73 kg/h 조건에서 20 kg/$cm^2$의 가스화기에 대한 안정적인 미분탄 공급특성을 확인할 수 있었으며, 이러한 미분탄 공급 조건에서 CO 40~45%, $H_2$ 16~20%, $CO_2$ 5~8% 조성의 양질의 합성가스를 평균적으로 $230{\sim}50Nm^3/h$ 안정적으로 제조할 수 있었다.

  • PDF

A Study on the Safety Performance Evaluation Method of Blowers for 1kW Class Stationary Fuel Cell System (1kW급 건물용 연료전지시스템 블로워의 안전성능 평가방법에 관한 연구)

  • Lee, Jungwoon;Seo, Wonseok;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.127.2-127.2
    • /
    • 2010
  • 우리나라는 기후변화 대응을 준비하기위해 2008년도에 수립한'국가에너지기본계획(2008-2030)'에 따라 2030년까지 신재생에너지 비중을 2.4%에서 11%까지 달성을 목표로 정하고 신재생에너지 분야를 성장시키기 위해 국가기술개발 및 산업화 전략을 수립해 추진하고 있다. 이에 발맞추어 건물용 연료전지시스템의 경우, 2006년도부터 1kW급 가정용 연료전지시스템 모니터링 사업의 일환으로 3년간 210대가 도시가스사 및 지자체 등을 중심으로 설치되어 운전되어지고 있다. 특히, 2010년부터 시범보급사업이 추진되어 올해 200대를 시작으로 2011년에 300대, 2012년에 500대가 일반가정에 보급되어질 예정이다. 하지만 현재 6천만원인 연료전지시스템 가격을 실제 보급가능한 가격인 5백만원 이하로 저감시키는 것이 현 시점에서 가장 시급한 문제로 대두되어지고 있는 실정이다. 본 연구에서는 그린홈 보급확대를 위한 건물용 연료전지의 보조기기인 블로워의 가격저감을 위한 연구의 일환으로 블로워의 안전성능 평가방법을 개발하여 보조기기의 가격저감 및 안전성을 확보하고자 한다. 1kW급 건물용 연료전지시스템의 여러 블로워 중 도시가스용 연료승압 블로워, 선택산화 공기 블로워, 버너 공기 블로워 및 캐소드 공기 블로워의 안전성능 평가방법을 제시함으로서, 국내 블로워 제조사의 설계방향을 제시하고 연료전지시스템의 안전성을 확인하고자 한다. 특히, 내구성, 기밀, 가혹조건시험 및 소음, 진동, 습도, 온도와 같은 내주위환경시험 등의 평가결과를 제조사에 feedback하여 안전성능 개선에 이바지하고자 한다.

  • PDF

KIER Liquefaction R & D's status (KIER 액화 기술 개발 현황)

  • Yang, Jung-Il;Yang, Jung Hoon;Lee, Ho-Tae;Chun, Dong Hyun;Kim, Hak-Joo;Jung, Heon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.110.1-110.1
    • /
    • 2010
  • A bench scale slurry bubble column reactor (SBCR) with active-Fe based catalyst was developed for the Fischer-Tropsch synthesis (FTS) reaction. Considering the highly exothermic reaction heat generated in the bench scale SBCR, an effective cooling system was devised consisting of a U-type dip tube submerged in the reactor. Also, the physical and chemical properties of the catalyst were controlled so as to achieve high activity for the CO conversion and liquid oil ($C_{5+}$) production. Firstly, the FTS performance of the FeCuK/$SiO_2$ catalyst in the SBCR under reaction conditions of $265^{\circ}C$, 2.5 MPa, and $H_2/CO=1$ was investigated. The CO conversion and liquid oil ($C_{5+}$) productivity in the reaction were 88.6% and 0.226 $g/g_{cat}-h$, respectively, corresponding to a liquid oil ($C_{5+}$) production rate of 0.03 bbl/day. To investigate the FTS reaction behavior in the bench scale SBCR, the effects of the space velocity and superficial velocity of the synthesis gas and reaction temperature were also studied. The liquid oil production rate increased upto 0.057 bbl/day with increasing space velocity from 2.61 to 3.92 $SL/h-g_{Fe}$ and it was confirmed that the SBCR bench system developed in this research precisely simulated the FTS reaction behavior reported in the small scale slurry reactor.

  • PDF

Test results of an inverter system for 750kW gearless wind turbine (750kW gearless 풍력발전기 인버터 시험)

  • Son, Yoon-Gyu;Suh, Jae-Hak;Kwon, Sei-Jin;Jang-Seung-Duck;Oh, Jong-Seok;Hwang-Jin-Su;Kang, Sin-Il;Park, Ga-Woo;Kwon, O-Jung;Chung-Chin-Hwa;Han-Kyung-Seop;Chun-Chung-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.59-63
    • /
    • 2005
  • The 800-kW PM (permanent magnet) synchronous generator is developed as a wind power generator. The matching converter is designed to control the torque and power depending on the wind speed regime. The generator starts to generate the power at the speed of 9 rpm and the rated output is generated at the speed of 25 rpm. The rated output power of an inverter is 750 kW when the PM synchronous generator is delivering 800 kW to the inverter. The inverter is specially designed to perform the maximum power point tracking (MPPT) at the low wind speed regime that is typical wind environment in Korea. The inverter test was done with a 2 MW M-G system at KERI (Korea Electric Research Institute). The M-G set has a 2 MW motor driver and a 38:1 gear to match the speed between the motor and the PM generator. The torque simulating the wind is applied to the PM generator by a DC motor. The test results show the inverter efficiency of $94.3\%$ at the rated power generating condition. The measured values show that the MPPT algorithm is working well. Overall reliability will be verified through the long-term site test.

  • PDF