• Title/Summary/Keyword: New correction factor

Search Result 312, Processing Time 0.021 seconds

AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System (인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어)

  • Park, Gwi-Geun;Choi, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

Seismic structural demands and inelastic deformation ratios: a theoretical approach

  • Chikh, Benazouz;Mebarki, Ahmed;Laouami, Nacer;Leblouba, Moussa;Mehani, Youcef;Hadid, Mohamed;Kibboua, Abderrahmane;Benouar, Djilali
    • Earthquakes and Structures
    • /
    • v.12 no.4
    • /
    • pp.397-407
    • /
    • 2017
  • To estimate the structural seismic demand, some methods are based on an equivalent linear system such as the Capacity Spectrum Method, the N2 method and the Equivalent Linearization method. Another category, widely investigated, is based on displacement correction such as the Displacement Coefficient Method and the Coefficient Method. Its basic concept consists in converting the elastic linear displacement of an equivalent Single Degree of Freedom system (SDOF) into a corresponding inelastic displacement. It relies on adequate modifying or reduction coefficient such as the inelastic deformation ratio which is usually developed for systems with known ductility factors ($C_{\mu}$) and ($C_R$) for known yield-strength reduction factor. The present paper proposes a rational approach which estimates this inelastic deformation ratio for SDOF bilinear systems by rigorous nonlinear analysis. It proposes a new inelastic deformation ratio which unifies and combines both $C_{\mu}$ and $C_R$ effects. It is defined by the ratio between the inelastic and elastic maximum lateral displacement demands. Three options are investigated in order to express the inelastic response spectra in terms of: ductility demand, yield strength reduction factor, and inelastic deformation ratio which depends on the period, the post-to-preyield stiffness ratio, the yield strength and the peak ground acceleration. This new inelastic deformation ratio ($C_{\eta}$) is describes the response spectra and is related to the capacity curve (pushover curve): normalized yield strength coefficient (${\eta}$), post-to-preyield stiffness ratio (${\alpha}$), natural period (T), peak ductility factor (${\mu}$), and the yield strength reduction factor ($R_y$). For illustrative purposes, instantaneous ductility demand and yield strength reduction factor for a SDOF system subject to various recorded motions (El-Centro 1940 (N/S), Boumerdes: Algeria 2003). The method accuracy is investigated and compared to classical formulations, for various hysteretic models and values of the normalized yield strength coefficient (${\eta}$), post-to-preyield stiffness ratio (${\alpha}$), and natural period (T). Though the ductility demand and yield strength reduction factor differ greatly for some given T and ${\eta}$ ranges, they remain take close when ${\eta}>1$, whereas they are equal to 1 for periods $T{\geq}1s$.

A Study on Step Up-Down AC-DC Converter with DCM-ZVS of High Performance (고성능 DCM-ZVS 스텝 업-다운 AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of IKEEE
    • /
    • v.16 no.4
    • /
    • pp.335-342
    • /
    • 2012
  • This paper is studied on a new DCM-ZVS step up-down AC-DC converter of high performance, that is, high system efficiency and power factor correction (PFC). The switching devices in the proposed converter are operated by soft switching technique using a new quasi-resonant circuit, and are driven with discontinuous conduction mode (DCM) according to pulse width modulation (PWM). The quasi-resonant circuit uses a step up-down inductor and a loss-less snubber capacitor. The proposed converter with DCM also simplifies the requirement of control circuits and reduces the number of control components. The input AC current waveform in the proposed converter becomes a quasi-sinusoidal waveform proportional to the magnitude of input AC voltage under constant switching frequency. As a result, the proposed converter obtains low switching power loss and high efficiency, and its input power factor is nearly in unity. The validity of the analytical findings is confirmed by some computer simulation results and experimental results.

The Response Correction Function of TL Dosimeter for Shallow Dose Assessment in Tl-204 Beta Fields (Tl-204 베타선장에서의 피부선량평가를 위한 열형광선량계의 베타보정함수)

  • Lee, Sang-Yoon;Kim, Jang-Lyul;Seo, Kyung-Won
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.381-388
    • /
    • 1994
  • Recently, the American National Standards Institute (ANSI) had made some changes in the radiation sources specified from those in the original performance test criteria ANSI N13. 11-1983. In case or beta category, in addition to the high-energy $^{90}$ Sr/$^{90}$ Y beta source, the $^{204}$ Tl source was added because many workplaces have significant levels of lower energy betas. In this study, the performance or the Teledyne PB-3 personnel dosimetry system in the fields of $^{204}$ Tl and $^{90}$ Sr/ $^{90}$ Y beta was investigated using the PTB beta secondary standard sources. The new beta correction function of PB-3 personnel dosimetry system for $^{204}$ Tl beta was also developed in this response experiment. The results show that the Teledyne PB-3 personnel dosimetry system is very effective for $^{90}$ Sr/ $^{90}$ Y beta dose assessment. In case of $^{204}$ Tl beta radiation, however, the results of simple performance test indicated that the use of beta correction factor(=2.088) which was recommanded by manufacturer may result in unexpectable overestimation of delivered dose by about 60%, while the use of developed beta correction function could measure the delivered doses in errors of 15%.

  • PDF

Optimal Period by Calculating and Appling Correction Factor based on Setting of Non-Working Days of Construction Projects (건설공사의 작업불능일 기준설정에 의한 보정계수 계산 및 적용을 통한 최적공기 산정)

  • Lee, Pil-Yoon;Lee, Seong-Won;Byun, Yo-Seph;Cho, Choong-Yeun;Lee, Min-jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.669-676
    • /
    • 2018
  • Schedule management in construction work is an important step for determining the construction period. On the other hand, there is a difference between the planned schedule and execution schedule because the estimation and calculation of Non-Working days, in which possible at the design stage is not performed properly. This paper proposes a method for estimating the working days by analyzing characteristics of the major work type and estimating the Non-Working days reflecting the Chuseok and New Year Holidays, which is the closest method to the actual work in the schedule planning. By applying the correction factor of the existing method and the improved method for the same construction in the same site, improved method was reduced by 22 days (9.1%) based on the actual working days. The importance of schedule management was confirmed as an example by comparing the data before and after the application of the standard (plan). These results show that the schedule delays, which are caused by the inconsistency between actual working days calculation that had been practiced conventionally and the working days on the schedule table, can be prevented. In addition, it will help to establish a schedule plan that is closer to reality.

A Study on the Performance of Multicast Transmission Protocol using FEC Method and Local Recovery Method based on Receiver in Mobile Host (이동 호스트에서 FEC기법과 수신자 기반 지역복극 방식의 멀티캐스트 전송 프로토콜 연구)

  • 김회옥;위승정;이웅기
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.1
    • /
    • pp.68-76
    • /
    • 2002
  • Multicast in mobile host has the problem of hast mobility, multicast decision, triangle routing, tunnel convergence, implosion of retransmission, and bandwidth waste. In particular, the bandwidth waste in radio is a definite factor that decreases transmission rate. To solve the problems, this paper proposes a new multicast transmission protocol called FIM(Forward Error Correction Integrated Multicast), which supports reliable packet recovery mechanism by integrating If Mobility Support for the host mobility, IGMP(Interned Group Management Protocol) for the group management, and DVMRP(Distance Vector Multicast Routing Protocol) for the multicast routing, and it also uses FEC and the local recovery method based on receiver. The performance measurement is performed by dividing the losses into the homogeneous independent loss, the heterogeneous independent loss, and the shared source link loss model.. The result shows that the performances improves in proportion to the size of local areal group when the size of transmission group exceeds designated size. This indicates FIM is effective in the environment where there are much of data and many receivers in the mobile host.

  • PDF

Single-stage Power Factor Corrected AC-to-DC Converter for sustain/reset Driving Power Supply of PDP TV (PDP TV의 sustain/reset 구동전원 공급을 위한 1단방식의 역률보상형 AC-to-DC 컨버터)

  • Kang, Feel-Soon;Park, Jin-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.2
    • /
    • pp.282-289
    • /
    • 2008
  • To improve the efficiency of PDP TV, it should minimize the power losses transpired during AC-to-DC power conversion and PDP driving process. Generally the input power supply for PDP driving employes a two-stage power factor corrected converter, and it needs additional DC-to-DC converters to supply driving power for reset circuit ed sustain driver, which has high power consumption. However, such a circuit configuration has a difficulty for the PDP market requires low cost. To alleviate this problem, a new circuit composition is presented. It integrates input power supply with reset and sustain driver in a single power stack The input power supply of the proposed circuit has a single-stage structure to minimize power conversion loss, and it directly supplies power to the sustain driver so as to reduce the system size and cost.

A Development of Damaged Spread Model of the Pine Needle Gall Midge Using Satellite Image Data (인공위성 화상데이터를 이용한 솔잎혹파리 피해 확산모델의 개발)

  • Ahn, Ki-Won;Lee, Hyo-Sung;Seo, Doo-Chun;Shin, Sok-Hyo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.2 s.12
    • /
    • pp.105-117
    • /
    • 1998
  • The main object of this study was to prove the effectiveness of satellite Image data for extraction of the pine needle gall midge damaged area in the part of Kangwon-do area, and to present the detailed procedure of a digital image processing for extraction of those damaged area. The effectiveness of extraction of damaged area was improved by using the BRCT(Backwards Radiance Correction Transformation) with DEM for the normalization of topographic effects. The topographic surface analysis of the extracted damaged area revealed that the general damaged area was at south-west and south-east aspect with the slope of 31 to 38 degrees, the temperature of 21 to 25, and 23% to 39% of the highest altitude mountains. The new damaged area in which expanded area was at 27 to 30 degree of slope, the aspect of 46 to 180 degrees, the temperature of $11^{\circ}C\;to\;12^{\circ}C$ and 27% to 39% of the highest altitude mountains. The NDI(New Damaged Index) was developed using the environment factor and simple vegetation index.

  • PDF

Forecasting Next Generation Technology Using Lotka-Volterra Competition Model and Factors for Technology Substitution (기술대체 영향요인과 Lotka-Volterra 경쟁 모형을 이용한 차세대 기술 예측)

  • Kim, Hyein;Jeong, Yujin;Yoon, Byungun
    • Journal of Korea Technology Innovation Society
    • /
    • v.20 no.4
    • /
    • pp.1262-1287
    • /
    • 2017
  • Recently, forecasting for next-generation technologies have influenced the competitiveness of companies. However, in previous studies, only extract factors influencing the adoption of technology have been investigated. Also, there are few researches on the importance of each decision factors or the competition between technologies. In this research, Lotka-Volterra model is used to confirm the technological competition in the new technology choice timing when the competition is intensified due to the emergence of new technologies. For purpose of this study, estimate the LVC model based on the data of the past competition and then derived the factors affecting the technology of competition and substitution from the literature survey. After that, we confirmed the factor value between the past and the present technology competition. The difference between the factor values derived from the previous step is used to revise the model estimated from the past data base. At this stage, regression analysis is used to derive the importance of each factor and use it as the weight. Through the correction model, the competitiveness is identified through 1:1 comparison with competition candidate technology and existing dominant design technology. In this research, we quantitatively propose the possibility that a specific technology can become a dominant design in the next generation, based on the difference in factor values and importance. This results will help the company's R&D strategy and decision making.

Residual Strength of Corroded Reinforced Concrete Beams Using an Adaptive Model Based on ANN

  • Imam, Ashhad;Anifowose, Fatai;Azad, Abul Kalam
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.2
    • /
    • pp.159-172
    • /
    • 2015
  • Estimation of the residual strength of corroded reinforced concrete beams has been studied from experimental and theoretical perspectives. The former is arduous as it involves casting beams of various sizes, which are then subjected to various degrees of corrosion damage. The latter are static; hence cannot be generalized as new coefficients need to be re-generated for new cases. This calls for dynamic models that are adaptive to new cases and offer efficient generalization capability. Computational intelligence techniques have been applied in Construction Engineering modeling problems. However, these techniques have not been adequately applied to the problem addressed in this paper. This study extends the empirical model proposed by Azad et al. (Mag Concr Res 62(6):405-414, 2010), which considered all the adverse effects of corrosion on steel. We proposed four artificial neural networks (ANN) models to predict the residual flexural strength of corroded RC beams using the same data from Azad et al. (2010). We employed two modes of prediction: through the correction factor ($C_f$) and through the residual strength ($M_{res}$). For each mode, we studied the effect of fixed and random data stratification on the performance of the models. The results of the ANN models were found to be in good agreement with experimental values. When compared with the results of Azad et al. (2010), the ANN model with randomized data stratification gave a $C_f$-based prediction with up to 49 % improvement in correlation coefficient and 92 % error reduction. This confirms the reliability of ANN over the empirical models.