• 제목/요약/키워드: Neutral voltage

검색결과 363건 처리시간 0.04초

혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향 (A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line)

  • 전용주;전명수
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

Research on Carried-Based PWM with Zero-Sequence Component Injection for Vienna Type Rectifiers

  • Ma, Hui;Feng, Mao;Tian, Yu;Chen, Xi
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.560-568
    • /
    • 2019
  • This paper studies the inherent relationship between currents and zero-sequence components. Then a precise algorithm is proposed to calculate the injected zero-sequence component to control the DC-Link neutral-point voltage balance, which can result in a more efficient and flexible neutral point voltage balance with a desirable performance. In addition, it is shown that carried-based PWM with the calculated zero-sequence component scheme can be equivalent to space-vector pulse-width modulation (SVPWM). Based on the proposed method, the optimal zero-sequence component of the feasible modulation indices is analyzed. In addition, the unbalanced load limitation of the DC-Link neutral-point voltage balance control is also revealed. Simulation and experimental results are shown to verify the validity and practicality of the proposed algorithm.

Neutral-point Potential Balancing Method for Switched-Inductor Z-Source Three-level Inverter

  • Wang, Xiaogang;Zhang, Jie
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1203-1210
    • /
    • 2017
  • Switched-inductor (SL) Z-source three-level inverter is a novel high power topology. The SL based impedance network can boost the input dc voltage to a higher value than the single LC impedance network. However, as all the neutral-point-clamped (NPC) inverters, the SL Z-source three-level inverter has to balance the neutral-point (NP) potential too. The principle of the inverter is introduced and then the effects of NP potential unbalance are analyzed. A NP balancing method is proposed. Other than the methods for conventional NPC inverter without Z-source impedance network, the upper and lower shoot-through durations are corrected by the feedforward compensation factors. With the proposed method, the NP potential is balanced and the voltage boosting ability of the Z-source network is not affected obviously. Simulations are conducted to verify the proposed method.

A Three Phase Three-level PWM Switched Voltage Source Inverter with Zero Neutral Point Potential

  • Oh Won-Sik;Han Sang-Kyoo;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제5권3호
    • /
    • pp.224-232
    • /
    • 2005
  • A new three phase three-level Pulse Width Modulation (PWM) Switched Voltage Source (SVS) inverter with zero neutral point potential is proposed. It consists of three single-phase inverter modules. Each module is composed of a switched voltage source and inverter switches. The major advantage is that the peak value of the phase output voltage is twice as high as that of a conventional neutral-point-clamped (NPC) PWM inverter. Thus, the proposed inverter is suitable for applications with low voltage sources such as batteries, fuel cells, or solar cells. Furthermore, three-level waveforms of the proposed inverter can be achieved without the switch voltage imbalance problem. Since the average neutral point potential of the proposed inverter is zero, a common ground between the input stage and the output stage is possible. Therefore, it can be applied to a transformer-less Power Conditioning System (PCS). The proposed inverter is verified by a PSpice simulation and experimental results based on a laboratory prototype.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

3-레벨 인버터 공간벡터 변조시의 중성점 전위 변동 보상법 (Compensating for the Neutral-Point Potential Variation in Three-Level Space-Vector PWM Method)

  • 서재형;김광섭;방상석;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.475-478
    • /
    • 2001
  • In performing the three-level SVPWM, it is nearly impossible to control the neutral-point potential exactly to the half of the dc-link voltage at all times. Therefore the inverter would produce an erroneous output voltage by this voltage unbalance. So the voltage unbalance has to be compensated in doing PWM, when the voltage unbalance occurs whether it is small or large, to make the inverter output voltage follow the reference voltage exactly the same. In this paper, a new compensating method for the neutral-point potential variation in a three-level inverter space vector PWM (SVPWM) is presented. By using the proposed method, the output voltage of the inverter can be made same as the reference voltage and thus the current and torque ripple of the inverter driven motor can be greatly improved even if the voltage unbalance is quite large. The proposed method is verified experimentally with a 3-level IGBT inverter.

  • PDF

SVPWM Strategies for Three-level T-type Neutral-point-clamped Indirect Matrix Converter

  • Tuyen, Nguyen Dinh;Phuong, Le Minh;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.944-955
    • /
    • 2019
  • In this paper, the three-level T-type neutral-point-clamped indirect matrix converter topology and the relative space vector modulation methods are introduced to improve the voltage transfer ratio and output voltage performance. The presented converter topology is based on combinations of cascaded-rectifier and three-level T-type neutral-point-clamp inverter. It can overcome the limitation of voltage transfer ratio of the conventional matrix converter and the high voltage rating of power switches of conventional matrix converter. Two SVPWM strategies for proposed converter are described in this paper to achieve the advantages features such as: sinusoidal input/output currents and three-level output voltage waveforms. Results from Psim 9.0 software simulation are provided to confirm the theoretical analysis. Hence, a laboratory prototype was implemented, and the experimental results are shown to validate the simulation results and to verify the effectiveness of the proposed topology and modulation strategies.

고온열을 이용한 고온수증기전기분해장치(HTSE)에 의한 수소생산 특성에 관한 전산유체해석적 연구 (A CFD Analysis Study on the Characteristics of Hydrogen Production by High Temperature Steam Electrolysis(HTSE) Using High Temperature Heat)

  • 한원희;최정식;윤석훈;윤두호;최재혁
    • 해양환경안전학회지
    • /
    • 제17권4호
    • /
    • pp.419-427
    • /
    • 2011
  • 고온수증기전기분해(HTSE) 장치의 수소생산 및 열 화학적 특성을 파악하고자 COMSOL $^Multiphysics^{(R)}$를 사용해 2차원 정상상태 수치해석을 실시하였다. 계산을 위한 주요 파라메터로는 작동전압, ASR(Area-specific Resistance) 및 유입가스의 온도와 압력 등이다. 해석결과 1.2454 V에서 Thermal-neutral Voltage가 나타나고, 작동 전압이 증가함에 따라 Cell의 내부 온도가 단조 증가하는 것이 아니라 Thermal-neutral Voltage를 기준으로 낮은 전압에서는 Cell의 온도가 감소하고, 높은 전압에서는 Cell의 온도가 증가하였다. 또한, ASR 값이 증가함에 따라 Cell 내부의 온도는 하강하고, 수소생산율도 낮아지는 경향을 보였다.

중성점전압보상 방식을 이용한 브러시리스직류전동기의 회전자위치 추정 (A Rotor Position Estimation of Brushless DC Motors using Neutral Voltage Compensation Method)

  • 송중호
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.491-497
    • /
    • 2004
  • 본 논문은 브러시리스직류전동기의 새로운 회전자위치추정 방법에 관한 것이다. 회전자 위치추정이 부정확하게 이루어졌을 때, 역기전력과 상전류 사이의 위상차가 나타나고 이는 다시 전동기의 토크리플을 일으킨다는 사실은 알려져 있다. 이러한 추정오차를 줄이기 위하여 인버터의 정상모드 기간 중에 나타나는 중성점전압을 기반으로 하는 새로운 방법을 제안하고 있다. 이 중성점전압이 효과적인 회전자 위치 추정오차의 한 지표임을 확인하고, 중성점전압의 발생, 획득방법, 보상방법 등을 다루고 있다. 본 알고리즘은 전동기 단자전압센서와 단일 직류링크 전류센서 만을 이용하여 실현할 수 있으며, 관련 시뮬레이션 및 실험결과는 그 타당성을 보여주고 있다.

선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성 (Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships)

  • 이윤형;류기탁
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.689-696
    • /
    • 2018
  • 계통 접지(system grounding)는 어떤 이상전압 유입이나 지락 고장 등으로부터 전력 계통의 안정성을 확보할 목적으로 전원의 중성점에 적용하는 것이다. 선박에서 주로 적용되는 계통 접지는 비접지 시스템과 저항 접지 시스템이다. 440V 선박은 비접지 시스템을 적용하고, 3.3kV, 6.6kV, 11kV의 MV(medium voltage) 시스템을 사용하는 선박은 저항 접지 시스템 중에서 주로 고저항접지 방식을 적용한다. 지락 고장은 전기시스템에서 발생하는 모든 고장의 95%정도이고, 지락고장 발생 시 전력 계통의 대지전압이 과도하게 증가하여 선내 절연 시스템에 악영향을 주게 된다. 본 논문에서는 선박에서 적용하는 저항접지 시스템에 대해 지락 고장 발생시 지락 정도에 따라 전력 계통의 대지전압 중성점의 변동 특성을 확인하고자 한다. 이를 위해 우선 접지 시스템의 종류에 따른 특성을 알아보고, 선박의 저항 접지 시스템의 대지전압 중성점에 대한 모델링을 유도한다. 최종적으로 다양한 변수환경에 따라서 대지전압, 선간전압, 중성점 전위 등이 어떻게 변동되는지 MATLAB을 이용한 시뮬레이션을 통해 지락고장 발생시 나타나는 선내 전압의 변화특성을 분석한다.