• Title/Summary/Keyword: Neutral type

Search Result 611, Processing Time 0.03 seconds

Analysis of Neutral Point Current in T-Type Three-Level PWM Converter (T-type 3-레벨 PWM 컨버터의 중성점 전류 분석)

  • Lee, Kui-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.1
    • /
    • pp.68-71
    • /
    • 2020
  • As a T-type three-level PWM converter has several intrinsic advantages, it has been widely studied for many applications. However, it requires an additional voltage control loop for balancing each DC link voltage. Generally, satisfying this requirement involves the use of an offset voltage to provide a neutral point current without affecting other variables, such as the total DC link voltage and three-phase input current. In this study, the theoretical relationship between the offset voltage and the neutral point current is analyzed. The results can be beneficial for effective voltage balancing controller design. The effectiveness of the analytical modeling is verified by simulation and experimental results.

Neutral Deinking of Old Newspapers Contaminated with Flexo Ink - Evaluation of the deinking efficiency of alcohol type neutral deinking agents - (플렉소 잉크가 포함된 신문고지의 중성 탈묵 - 알코올계 계면활성제의 효과 평가 -)

  • Ryu, Hoon;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.4 s.117
    • /
    • pp.31-40
    • /
    • 2006
  • Presence of old newspapers printed with waterbased flexographic inks leads to a significant loss of brightness of the deinked pulp by flotation process. It has been shown that neutral or acidic flotation deinking has many advantages in recycling of flexo printed newsprints. A comparative experimental study was performed to evaluate the deinking efficiency of three alcohol type deinking agents in flotation deinking of flexo printed newspapers. Zeta potential of neutral deinked pulp was less negative than alkaline deinked pulp. Also neutral deinking was advantages in reducing turbidity, COD, and cationic de-mands of deinking process water.

Influence of a Neutral Line on the Quench Behaviors of a Transformer Type SFCL (변압기형 초전도 한류기의 퀜치특성에 대한 중성선의 영향)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Koo, Kyung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2212-2213
    • /
    • 2008
  • In this paper, we studied the method for simultaneous quenching of a transformer type superconducting fault current limiter (SFCL) with two superconducting elements connected in series. Only an element between two elements of the transformer type SFCL was quenched like the case of the resistive type SFCL. By this quenching characteristics, the power burden of the superconducting element was increased. In order to solve this problem, we connected the neutral line between two superconducting elements and the center of secondary coils. The two elements were all quenched in the transformer type SFCL with a neutral line. As a result, the power burden of superconducting elements was decreased, so it was efficient for the increase of power capacity of the transformer type SFCL.

  • PDF

A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line (혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향)

  • Jeon, Yong-Joo;Jeon, Myung-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

A LONGITUDINAL STUDY ON THREE FACIAL GROWTH PATTERNS IN KOREANS WITH NORMAL OCCLUSION (정상교합자의 3가지 안면골 성장양상에 관한 누년적 연구)

  • Park, Krung-Duk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.273-286
    • /
    • 1995
  • The purpose of this study was to compare the difference of the growth aspects in three facial growth patterns. The biennial serial cephalometric radiographs of 33 samples(19males, 14females) with normal occlusion from 8.5 years to 18.5 yews of age were used in this study. The facial growth patterrn was categorized in 3 types(Drop type, Neutral type, Forward type) by the total amounts of the Y-axis which changed from 8.5 years to 18.5 years of age. The growth change of the craniofacial area during 10 years in each growth type was analyzed and was compared among the 3 growth types. The results of this study might be summarized as follows. 1. The samples that were classified by total change of the Y-axis during this study period were distributed to 52% of the neutral type, 27% of the forward type, 21% of the drop type. 2. The anterior growth of the maxilla to the cranial base(N per A) showed larger in the forward type than in other 2 types(p<0.05). 3. The palatal plane to the FH plane showed more anterior-superior inclination in the forward type with age during this study period. 4. The anterior growth of the mandible to the cranial base(N per Pog) appeared large in rank order, of largest the forward type, second the neutral type, and third the drop type(p<0.05). 5. During this study period the mandibular plane(SN/MN,FMA) showed more counterclockwise rotation in the forward type than in the drop type(p<0.05), and this tendency was stronger in males than in females(p<0.05). 6. The growth of the mandibular corpus length(Go-Me) showed smaller in the drop type than in the other 2 types(p<0.05). 7. In the forward type and the neutral type, the anterior growth of the mandible was larger than that of the maxilla(p<0.05). 8. In the craniofacial growth distances and angulations turned out to be somewhat variable, but the vertical proportion had a strong tendency whose original relation was maintained consistently during this study period. 9. Through these analyzed data, the profilograms on each growth type were constructed to evaluate individual growth pattern in the orthodontic diagnosis.

  • PDF

A Numerical Study on the Stack Effect and the Neutral Plane of a Single Simplified Shaft (단일 단순수직통로의 연돌효과와 중성대에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.143-152
    • /
    • 2009
  • The numerical analyses for each single simplified shaft with three type openings were carried out by using computational fluid dynamics model for the calculation of the pressure difference and the location of the neutral plane and the visualization of stack effect. As the height of shaft heighten, the pressure difference of stack effect is much deviated against the theoretical value. For the Type A models shorter than 30 m height of shaft and the Type B models longer than 30m, the simulation results for the location of the neutral plane are well agreed to the theoretical values with 5% less deviations just after the beginning of simulation (t = 10s). For the Type B models longer than 30m with multiple openings, therefore, it is possible to calculate the location of the neutral plane by using a CFD model. The phenomenon of the air flow of stack effect can be easily understood with the visualization of stack effect.

Ultrastructural and Histochemical Studies on the Epithelial Cells and Mucus-producing Cells of Korean Slug(Limax flavus L.) (한국산 노랑민달팽이(Limax flavus L.)의 표피상피세포와 점액형성세포에 관한 미세구조 및 조직화학적인 연구)

  • Chang, Nam-Sub
    • Applied Microscopy
    • /
    • v.18 no.2
    • /
    • pp.1-20
    • /
    • 1988
  • The species of the slug used in the experiment is Limax flavus L. For identifying the chemical characteristics of the epidermis, granules and mucus-producing cell of this animal is examined with methylene blue-basic fuchsin double stain and PAS-alcian blue reagent. For the ultrastructural research of the epidermal free surface, the epitheial cell and the parenchymal cell are used with scanning electron microscope and transmission elec-tron microscope respectively. I . Epidermal tissue The epidermal tissue of the slug is observed being divided into the dorsal and the ventral side(toot pad) respectively. 1) Dorsal epidermal tissue The dorsal epidermis of the slug is constituted with the simple columnar epithelium and the microvilli are compacted on the epidermal free surface. Two different types of the secretory granules of the neutral and the acid mucus are observed between the epithelial cells, and the neutral mucous granules are highest electron-dense but the acid mucous granules are observed to be electron-lucent. 2) Foot epidermal tissue The Foot epidermis is formed with the taller simple columnar epithelium than the dorsal epidermis and these cells have both a large number of the microvilli and a few number of the large villi. The secretory granules of three different types, which are acid, neutral and mixed mucous granule of two different types are observed between the epithelial cells. The neutral mucous granules are highest electron dense but the acid mucous granules are observed to be electron-lucent. II . Mucous granule-producing cell and mucus-producing cells Seven different types of the granules-producing cell and the mucus-producing cells are observed between the parenchyma. 1) A-type of acid mucous granule-producing cell The electron-lucent granules are largely occupied in the cytoplasm of these cells and then the granules are surrounded by irregular membrane. These electron-lucent granules exhibit alcianophilia with PAS-alcian blue reaction, so these granules are certified to be acid mucopolysaccharide. 2) B-type of acid mucus-producing cell The nucleus and the cytoplasm of these cells are pushed by the acid mucus of the electron-lucent toward the cell membrane. This mucus has been confirmed to be the acid mucopolysaccharide with PAS-alcian blue reagent. 3) A-type of neutral mucous granule-producing cell These cells contain the electron-dense round granules with approximately $1{\mu}m$ in diameter, which exhibit strongly PAS-positive reaction. These granules are confirmed to be the neutral mucoplysaccharide. 4) B-type of neutral mucous granule-producing cell These cells contain two different types of electron dense granules and electron-lucent granules; The former exhibits to be strongly PAS-positive and the latter to have alcianophilia reaction respectively. 5) C-type of neutral mucus-producing cell These cells are similar to the shape and the size of the B-type of mucus-producing cell but these two different types of cells are stained with reversing properties to each other. The mucus of the C-type cell that electron-lucent is largely occupied in the cytoplasm that exhibits strongly PAS-positive reaction. 6) D-type of neutral mucous granule-producing cell These cells contain round granules about $1{\mu}m$ in size which are observed to be medium electron-dense granules and those granules are stained brightly red with PAS-weak positive reaction. The granules are certified to be neutral mucopolysaccharide. 7) E-type of neutral mucous granule-producing cell These cells are similar to the shape and the size of the D-type of neutral mucous granule-producing cell. These cells contain a large number of granules with about $1{\mu}m$ in diameter showing electron-lucent and then granules are seen to be PAS-weak positive reaction. III. Parenchyma The clear cell and dark cell are found in the parenchyma of the Limax flavus L. 1) Clear cell These cells are round formed and the nucleus of the cells are larger than cytoplasm. These cells which have the electron-lucent cytosol possess poorly developed organelles. 2) Dark cell These cells are found to be dark cells due to high electron-density, which exhibit strongly methylene-blue reaction from double stain of methylene blue-basic fuchsin.

  • PDF

The study on effect of electric train passing automatic changover system in neutral section of electric railway (절연구간 자동전원 절체시스템을 운행하는 전기차량 영향성 연구)

  • Hong, Hyun-Pyo;Yang, Sang-Woong;Cha, Han-Ju;Kim, Cheol-Hwan;Lee, Hee-Soon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.195-203
    • /
    • 2011
  • This paper is to analysis technical characteristics occured in the eletric train power conversion device passing automatic changover system in neutral section of electric railway. Power conversion devices in electric train are classified according to the current type and voltage type. The results of this study is used to ensure the stability of electric train in neutral section of electric railway.

  • PDF

GLOBAL EXPONENTIAL STABILITY OF ALMOST PERIODIC SOLUTIONS OF HIGH-ORDER HOPFIELD NEURAL NETWORKS WITH DISTRIBUTED DELAYS OF NEUTRAL TYPE

  • Zhao, Lili;Li, Yongkun
    • Journal of applied mathematics & informatics
    • /
    • v.31 no.3_4
    • /
    • pp.577-594
    • /
    • 2013
  • In this paper, we study the global stability and the existence of almost periodic solution of high-order Hopfield neural networks with distributed delays of neutral type. Some sufficient conditions are obtained for the existence, uniqueness and global exponential stability of almost periodic solution by employing fixed point theorem and differential inequality techniques. An example is given to show the effectiveness of the proposed method and results.

Neutral Current Calculation in One Step Type Pole (1단장주 중성선 전류 계산)

  • Seo, Hun-Chul;Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.480-481
    • /
    • 2006
  • This paper presents computation of the neutral torrent using KEPCO's distribution system model which is composed by only one step type poles. The used system model is modelled and simulated by using ATPDraw. And the neutral current is calculated by using EMTP/MODELS.

  • PDF