• 제목/요약/키워드: Neutral axis.

검색결과 223건 처리시간 0.025초

Fracture analysis of functionally graded beams with considering material non-linearity

  • Rizov, Victor I.
    • Structural Engineering and Mechanics
    • /
    • 제64권4호
    • /
    • pp.487-494
    • /
    • 2017
  • The present paper deals with a theoretical study of delamination fracture in the Crack Lap Shear (CLS) functionally graded beam configuration. The basic purpose is to analyze the fracture with taking into account the material non-linearity. The mechanical behavior of CLS was described by using a non-linear stress-strain relation. It was assumed that the material is functionally graded along the beam height. The fracture was analyzed by applying the J-integral approach. The curvature and neutral axis coordinate of CLS beam were derived in order to solve analytically the J-integral. The non-linear solution of J-integral obtained was verified by analyzing the strain energy release rate with considering material non-linearity. The effects of material gradient, crack location along the beam height and material non-linearity on fracture behavior were evaluated. The J-integral non-linear solution derived is very suitable for parametric studies of longitudinal fracture in the CLS beam. The results obtained can be used to optimize the functionally graded beam structure with respect to the fracture performance. The analytical approach developed in the present paper contributes for the understanding of delamination fracture in functionally graded beams exhibiting material non-linearity.

Cracking and bending strength evaluations of steel-concrete double composite girder under negative bending action

  • Xu, Chen;Zhang, Boyu;Liu, Siwei;Su, Qingtian
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.371-384
    • /
    • 2020
  • The steel-concrete double composite girder in the negative flexural region combines an additional concrete slab to the steel bottom flange to prevent the local steel buckling, however, the additional concrete slab may lower down the neutral axis of the composite section, which is a sensitive factor to the tensile stress restraint on the concrete deck. This is actually of great importance to the structural rationality and durability, but has not been investigated in detail yet. In this case, a series of 5.5 m-long composite girder specimens were tested by negative bending, among which the bottom slab configuration and the longitudinal reinforcement ratio in the concrete deck were the parameters. Furthermore, an analytical study concerning about the influence of bottom concrete slab thickness on the cracking and sectional bending-carrying capacity were carried out. The test results showed that the additional concrete at the bottom improved the composite sectional bending stiffness and bending-carrying capacity, whereas its effect on the concrete crack distribution was not obvious. According to the analytical study, the additional concrete slab at the bottom with an equivalent thickness to the concrete deck slab may provide the best contributions to the improvements of crack initiation bending moment and the sectional bending-carrying capacity. This can be applied for the design practice.

용접변형의 고정도 예측을 위한 지배인자의 정당성 검증 (Verification of Validity of Governing Factors in High Accurate Prediction of Welding Distortion)

  • 이재익;장경호;김유철
    • Journal of Welding and Joining
    • /
    • 제31권5호
    • /
    • pp.7-14
    • /
    • 2013
  • The legitimacy of dominating factor in the high accuracy prediction of welding distortion was investigated for butt welding and fillet welding. When out-of-plane distortion was measured by the experiment objecting to butt welding, if tack welding was easily performed, the position of a neutral axis was variously changed by the irregularity. Then, there have been a case that out-of-plane distortion was generated in the unexpected direction. This case should be especially noted. New model for the experiment was proposed so as to solve this problem. As it was elucidated by the case of fillet welding, it was verified that the analysis should be carried out with satisfying the yield condition (especially at high temperature above 700 degree Celsius) and with closely simulating the penetration shape (heat input in weld metal) in order to solve the proposition that is the high accuracy prediction of welding distortion. It was confirmed that residual stress is highly predicted because welding distortion is highly predicted, too.

매립형 역T형 합성보의 휨내력에 관한 실험적 연구 (An Experimental Study on Flexural Strength of Inverted T-shaped Composite Beams encased with concrete)

  • 장희성;정재훈;김진무;주경재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권3호
    • /
    • pp.145-152
    • /
    • 2000
  • In simply supported composite beams, the neutral axis of the composite cross section is usually located near the top flange of the steel H-shape, so that the top flange does not impart much strength to the member. This suggests that omitting the top flange entirely could be a means to lower the cost of the beam without greatly reducing the strength. However, It is not easy for inverted T-shaped composite beam to construct and to apply continuous beam which has negative bending moment. As a result, it would get more workability and decrease capability of lateral buckling and local buckling, if the bottom flange of inverted T-shaped steel used as a form. Therefore. the objectives of this study are to investigate strength and behaviors of inverted T-shaped composite beam which web is encased by concrete and to grasp bending capacity and efficiency of composite by comparing and analyzing in test piece.

  • PDF

Extensible Elastica Solutions on the Large Deflection of Fiber Cantilever with Circular Wavy Crimp (I) - Derivation of Models and Their Solutions-

  • Jung Jae Ho;Kang Tae Jin
    • Fibers and Polymers
    • /
    • 제6권1호
    • /
    • pp.55-65
    • /
    • 2005
  • Extensible elastica solutions of two-dimensional deflection of crimped fiber cantilever of circular wavy crimp were obtained for one end clamped boundary under concentrated, inclined and dead tip load Fiber was also regarded as a linear elastic material. Crimp was described as a combination of semicircular arcs smoothly connected with each other having con­stant curvature of all the same magnitude and alternative sign. Also the inclined load direction was taken into account. The solutions were expressed as the recursive forms of integrals in two different cases, which can also be transformed to elliptic integrals respectively. Comparing the data with inextensible ones was carried out. Consequently in the solution, the normal strain of neutral axis is expressed in terms of cross-sectional area, second moment of area and normalized load parameter. Examples of the circular cross-sectioned fiber are presented. As a result, the differences of normalized load between inexten­sible and extensible elastica solutions when the radius ratio becomes 0.1 were maximum $\Lambda$ = 0.1.

Implementation of a macro model to predict seismic response of RC structural walls

  • Fischinger, Matej;Isakovic, Tatjana;Kante, Peter
    • Computers and Concrete
    • /
    • 제1권2호
    • /
    • pp.211-226
    • /
    • 2004
  • A relatively simple multiple-vertical-line-element macro model has been incorporated into a standard computer code DRAIN-2D. It was used in blind predictions of seismic response of cantilever RC walls subjected to a series of consequent earthquakes on a shaking table. The model was able to predict predominantly flexural response with relative success. It was able to predict the stiffness and the strength of the pre-cracked specimen and time-history response of the highly nonlinear wall as well as to simulate the shift of the neutral axis and corresponding varying axial force in the cantilever wall. However, failing to identify the rupture of some brittle reinforcement in the third test, the model was not able to predict post-critical, near collapse behaviour during the subsequent response to two stronger earthquakes. The analysed macro model seems to be appropriate for global analyses of complex building structures with RC structural walls subjected to moderate/strong earthquakes. However, it cannot, by definition, be used in refined research analyses monitoring local behaviour in the post critical region.

Secondary resonances of a microresonator under AC-DC electrostatic and DC piezoelectric actuations

  • Zamanian, M.;Hosseini, S.A.A.
    • Structural Engineering and Mechanics
    • /
    • 제42권5호
    • /
    • pp.677-699
    • /
    • 2012
  • This article studies the secondary resonances of a clamped-clamped microresonator under combined electrostatic and piezoelectric actuations. The electrostatic actuation is induced by applying the AC-DC voltage between the microbeam and the electrode plate that lies at the opposite side of the microbeam. The piezoelectric actuation is induced by applying the DC voltage between upper and lower sides of piezoelectric layer. It is assumed that the neutral axis of bending is stretched when the microbeam is deflected. The drift effect of piezoelectric layer (the phenomenon where there is a slow increase of the free strain after the application of a DC field) is neglected. The equations of motion are solved by using the multiple scale perturbation method. The system possesses a subharmonic resonance of order one-half and a superharmonic resonance of order two. It is shown that using the DC piezoelectric actuation, the sensitivity of AC-DC electrostatically actuated microresonator under subharmonic and superharmonic resonances may be tuned. In addition, it is shown that the tuning domain of the microbeam under combined electrostatic and piezoelectric actuations at subharmonic and superharmonic conditions is larger than the tuning domain of microbeam under only the electrostatic actuation.

Vapor Transport Epitaxy에 의한 GaN의 성장과 특성 (Growth and Properties of GaN by Vapor Transport Epitaxy)

  • 이재범;김선태
    • 한국재료학회지
    • /
    • 제16권8호
    • /
    • pp.479-484
    • /
    • 2006
  • Highly c-axis oriented poly-crystalline GaN with a dimension of $1{\sim}3\;{\mu}m$ was deposited on $c-Al_2O_3$ substrate by vapor transport epitaxy (VTE) method at the temperature range of $900{\sim}1150^{\circ}C$. XRD intensities from (00'2) plane of grown GaNs were increased with reaction conditions which indicate the improvement of the crystal quality. In the PL spectra measured at 10 K, the spectrum composed with the neutral-donor bound exciton-related emission at 3.47 eV, crystal defect-related emission band at 3.42 eV and with its phonon replicas. The fact that intensity of $I_2$ were increased and FWHM were decreased with growth conditions means that the quality of GaN crystals were improved. With this simple VTE technology, we confirm that the GaNs were simply deposited on sapphire substrate and crystal quality related to optical properties of GaN grown by VTE were relatively good. PL emission without deep level emission in spite of polycrystalline structure can be applicable to the fabrication of large area and low cost optical devices using poly-GaN grown by VTE.

신형상 층고절감형 합성보의 최적단면 도출에 관한 연구 (A Study on Optimum Section of New Type Steel-Concrete Composite Beam)

  • 윤명호;이윤희
    • 복합신소재구조학회 논문집
    • /
    • 제2권3호
    • /
    • pp.30-35
    • /
    • 2011
  • 본 연구에서는 신형상 층고절감형 합성보에 대한 최적단면을 도출하기 위해 단면성능 계산 프로그램을 개발하여 단면성능에 대해 비교 분석을 하였다. 신형상 합성보는 상부 플랜지 하부에 바닥시스템이 위치하여 전통적인 공법에 비해 층고절감의 효과와 최적단면으로 설계시 공기의 단축과 비용의 절감은 물론 물량의 감소를 기대 할 수 있다. 그러나 단면은 기존 H형강 보와 달리 상하 비대칭으로 중립축의 위치가 중앙에 위치하지 않기 때문에 상하연단에 대한 단면계수가 같지 않게 된다. 이에 따른 상하플랜지 판요소의 두께비에 따른 매개 변수적 분석이 요구된다. 따라서, 본 연구에서는 단면의 상부 플랜지 두께에 대한 하부 플랜지 두께의 비에 따른 중립축위치, 단면계수의 변화추이를 분석하여 최적단면을 도출하는데 주목적을 두었다.

프리스트레스트 콘크리트 합성거더 교량의 피로해석 (Fatigue Analysis of Prestressed Concrete Composite Girder Bridges)

  • 김지상;오병환
    • 콘크리트학회지
    • /
    • 제5권4호
    • /
    • pp.135-144
    • /
    • 1993
  • 본 논문은 일정진폭의 피로하중을 받는 피리스트레스트 콘크리트 합성거더 교량의 피로해석 절차를 시간의 진행에 따른 재료 특성의 변화양상을 고려하여 정립하였다. 본 논문에서 제시된 방법은 피로하중의 재하에 따라 균열이 진전되면서 생기는 중립축의 이동현상을 고려하였으며, 해석결과는 기존의 제한된 실험자료와 부합되었다. 또한, 건설부에서 규정한 표준 I 단면의 프리스트레스트 콘크리트거더의 피로저항능력을 검토한 결과 충분한 안전도를 갖고 있음을 확인하였다. 그리고 이 방법의 적용으로 임의의 단면형상을 갖는 프리스트레스트 콘크리트 거더의 피로특성을 S-N 곡선의 형태로 나타낼 수 있도록 하였으며, 이는 향후 변동진폭하중하에서의 피로거동 해석에 유용하게 이용될 수 있을 것으로 사료된다.