• Title/Summary/Keyword: Neutral Angle

Search Result 164, Processing Time 0.036 seconds

Effects of Knee and Foot Position on EMG Activity and Ratio of the Vastus Medialis Oblique and Vastus Lateralis during Squat Exercise (스쿼트 운동시 자세가 안쪽빗넓은근과 가쪽넓은근의 근활성도 및 근활성비에 미치는 효과)

  • Kim, Hyun-Hee;Song, Chang-Ho
    • Journal of muscle and joint health
    • /
    • v.17 no.2
    • /
    • pp.142-150
    • /
    • 2010
  • Purpose: The purpose of this study was to examine EMG activities and VMO/VL ratio of the vastus medialis oblique, vastus lateralis, and rectus femoris during squat exercise (knee angle: 15, 45, and 60 degrees; tibial rotation: internal rotation, neutral, and external rotation). Methods: Twelve subjects performed squat exercise at each knee angle and tibial rotation while electromyographic (EMG) activity was collected. Statistical analysis consisted of two-way repeated measures analysis of variance with post hoc analysis. Results: There were significant main effects of knee angles and foot positions and interaction effect on EMG activities of vastus medialis oblique and vastus lateralis. VMO/VL ratios were significantly different by tibial rotations and there was an interaction effect. A neutral position produced significantly more VMO/VL activity ratio than that from internally rotated position and externally rotated position at 60 degrees. Conclusion: Considering the interaction effects for EMG activity across quadriceps muscles tested, the 60 degrees knee angle with a neutral foot position may provide the most effective condition for patients with acute patellofemoral syndrome.

Technology development on automatic changeover system in neutral section with energized condition of electric railway catenary system (절연구간 무접점 자동 전원절체 통과시스템 기술개발)

  • Hong, Hyun-Pyo;Han, Moon-Seob;Seo, Myung-Seok;Shin, Myong-Cheol;Yoon, Yong-Han;Kim, Jae-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.498-506
    • /
    • 2010
  • The neutral section was installed in order to prevent conflict with different phase angle source in electric railway catenary system. The speed of electric train reduced due to coasting operation by notch off when it passed the neutral section. And, the catenary wire was damaged and the accident might be happened because of the arc generation when the electric train passed the neutral section with notch on condition. This project has a goal to develop the automatic changeover system using by noncontactless semiconductor device in neutral section of catenary system so that the train pass as notch-on condition. In this first year, we obtain as following results such as domestic and international systems applications and completion requirements, development and analysis of stability for automatic changeover system, design of static switching device on automatic changeover system in neutral section and drawing up interface design and specifications according to equipment.

  • PDF

Study of neutral beam characteristics using SIMS depth profile and improvement of neutral beam flux (SIMS depth profile을 이용한 중성빔 특성 분석 및 flux 향상방안)

  • Kim, Seong-U;Park, Byeong-Jae;Min, Gyeong-Seok;Gang, Se-Gu;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.04a
    • /
    • pp.61-62
    • /
    • 2007
  • low angle forward reflected neutral beam etching system으로 식각한 후 SIMS depth profile을 이용하여 에너지 침투 깊이에 따른 중성빔 에너지를 분석하여 중성화 과정에서 에너지와 flux의 손실이 있었다. 기존의 two-grid 대신에 three-grid를 사용하여 에너지의 변화없이 이온 flux 및 중성빔 flux가 향상됨을 알 수 있었다.

  • PDF

The wave stability of the nonparallel natural convection flows adjacent to an inclined isothermal surface submerged in water at $4degC$ ($4degC$ 물에 잠겨있는 경사진 등온 벽주위 비평행 자연대류의 파형 안정성)

  • 황영규;장명륜
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.644-653
    • /
    • 1991
  • A wave instability problem is formulated for natural convection flows adjacent to a inclined isothermal surface in pure water near the density extremum. It accounts for the nonparallelism of the basic flow and temperature fields. Numerical solutions of the hydrodynamic stability equations constitute a two-point boundary value problem which are accurately solved using a computer code COLSYS. Neutral stability results for Prandtl number of 11.6 are obtained for various angles of inclination of a surface in the range from-10 to 30 deg. The neutral stability curves are systematically shifted toward modified Grashof number G=0 as one proceeds from downward-facing inclined plate(.gamma.<0.deg.) to upward-facing inclined plate (.gamma.>0.deg.). Namely, an increase in the positive angle of inclination always cause the flows to be significantly more unstable. The present results are compared with the results for the parallel flow model. The nonparallel flow model has, in general, a higher critical Grashof number than does the parallel flow model. But the neutral stability curves retain their characteristic shapes.

A Neutral-Voltage-Compensated Sensorless Control of Brushless DC Motor

  • Won, Chang-Hee;Song, Joong-Ho;Ick Choy;Lim, Myo-Taeg
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.59-64
    • /
    • 2003
  • This paper presents a new rotor position estimation method for brushless DC motors. The estimation error of the rotor position clearly provokes the phase shift angle misaligned between the phase current and the back-EMF waveforms, which causes torque ripple in brushless DC motor drives. Such an estimation error can be reduced with the help of the proposed neutral-voltage-based estimation method, which is structured as a closed loop observer. A neutral voltage appearing during the normal mode of the inverter operation is found to be an observable and control table measure, which can be used for estimating an exact rotor position. This neutral voltage is obtained from the DC-link current, the switching logic, and the motor speed values. The proposed algorithm, which can be easily implemented by using a single DC-link current and the motor terminal voltage sensors, is verified by simulation and experiment results.

A Comparison of Muscle Activation and Mechanical Loading according to the Degree of Ankle Joint Motion during a Sit-to-stand Task (앉았다 일어서기 동작 수행 시 발목 관절 각도에 따른 근 활성도 및 역학적 부하량의 비교)

  • Lee, Myung-Mo;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.4
    • /
    • pp.113-122
    • /
    • 2017
  • PURPOSE: The purpose of this study was to investigate the comparison of muscle activity and mechanical loading according to the angle of ankle joint during a sit-to-stand (STS) task. METHODS: Thirty-four young participants performed the STS in a randomized trial with the ankle joint at a neutral, 15 degrees dorsiflexion and 15 degrees plantarflexion angle in a fixed sitting posture with the knee in 105 degrees flexion. Muscle activity of the tibialis anterior (TA), rectus femoris (RF), biceps femoris (BF), and gastrocnemius medialis (GCM) was measured, and the parameters calculated in relation to mechanical loading were the STS-time, maximum peak, minimum peak, and total sum of mechanical loading. RESULTS: In the dorsiflexion position, the muscle activity of the TA and GCM showed a significant increase (p<.05), and the STS time, maximum peak and total sum of mechanical loading showed a significant difference compared to that in the neutral position (p<.05). In the plantarflexion position, the muscle activity of the RF and GCM showed a significant increase (p<.05), while that of the TA showed a significant decrease (p<.05) compared to that in the neutral position. And the minimum peak was significantly increased than the neutral position (p<.05), and the maximum peak and total sum of mechanical loading were showed significant difference compared with dorsiflexion position (p<.05). CONCLUSION: These results show that there is a difference in muscle activity and mechanical loading when performing the STS movement according to the change in the ankle joint angle.

The Effect of Medio-lateral Balance to Head Rotation in Stroke Patient (뇌졸중 환자의 머리회전 각도가 내.외측 균형에 미치는 영향)

  • Lee, Kwan-Sub;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.5
    • /
    • pp.334-339
    • /
    • 2012
  • Purpose: This study was conducted in order to compare the ability to control postural sway during perturbation when stroke patients received postural sway induced by head rotation. Methods: This study included 15 stroke patients and 15 healthy adults. Each group was measured by 3D motion analysis for determination of the angle of the neck in static position and by balance performance monitor for estimation of swaying angle in both neutral posture and head rotation position. These results were then analyzed in order to compare the healthy control group and the stroke patients group. Results: In both static posture ($60.7{\pm}4.81$) and dynamic posture ($51.46{\pm}6.87$, $70.8{\pm}6.55$), significant decreases were observed in the angle of head rotation of the patient group, compared to the healthy group (p<0.05), and significant decreases were observed in the sway angle of the patient group when in the neutral position ($3.62{\pm}7$, $24{\pm}0.60$) and head rotation ($3.04{\pm}0.80$, $51.46{\pm}6.87$), compared to the healthy group (p<0.05). Conclusion: According to these findings, patients with stroke tend to restrict the ROM of head rotation and swaying angle in dynamic posture and maintain their posture instability using limitation of head movement relative to the trunk and sway angle of area which is larger than that of affected side in unaffected side.

Simple Space Vector PWM Scheme for 3-level NPC Inverters Including the Overmodulation Region

  • Lee, Dong-Myung;Jung, Jin-Woo;Kwa, Sang-Shin
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.688-696
    • /
    • 2011
  • This paper proposes a simple space vector PWM (SVPWM) scheme including overmodulation operation for 3-level NPC (Neutral Point Clamped) Inverters. The proposed scheme features a simple decision and calculation procedure for determining switching times in the overmodulation range by utilizing the duty calculation method used in 2-level inverters and the minimum phase error projection method widely employed in motor drive systems. The proposed scheme does not need to detect the angle of the reference vector or calculate trigonometric functions to determine the magnitude of the voltage vector. The magnitude of the angle of the new reference voltage vector is decided in advance with the help of the Fourier Series Expansion to extend the linearity of the output voltage of 3-level inverters in the overmodulation region. Experimental results demonstrate the validity of the proposed SVPWM scheme including overmodulation operation for 3-level NPC inverters.