• Title/Summary/Keyword: Network Calibration

Search Result 256, Processing Time 0.025 seconds

등시지각 색 샘플링을 기반한 CIEL*a*b*-CMY 비선형 색변환

  • 오현수;이을환;유미옥;최환언;안석출
    • Proceedings of the Korean Printing Society Conference
    • /
    • 2000.12b
    • /
    • pp.5-10
    • /
    • 2000
  • In case of outputting the image with color printer, image is occurred color distortion by characteristics of paper, effect by overlap between neighbor dots and the mechanical characteristics if printer. Color calibration is needed to reduce this color distrotion. To color calibration, we select the color sample in printer color gamut. The accuracy of color calibration is determined by the number of sample, distribution, and calibration method. Generally, color space is selected the color sample dividing equal interval. In this case, the range of gamut of printed color patches is reduced due to the effect of inks overlap. Therefore, error is occurred when color transformation relatively. In this paper, we have the color sampling based on equi-visual perception and then reproduce the color using the Neural-Network and interpolation by LUT.

Inverse Calibration of a Robot Manipulator Using Neural Network (뉴럴 네트워크를 이용한 로봇 매니퓰레이터의 역보정)

  • 정동연;김종수;한성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.199-204
    • /
    • 1999
  • The robot inverse calibration method using a neural networks is proposed in this paper. A high-order networks has been used in this study. The Pi-Sigma networks uses linear summing units in the hidden layer and product unit in output layer. The inverse calibration model which compensates the difference of joint variables only between measuring value and analytic value about the desired pose(position orientation) of a robot is proposed. The compensated values are determined by using the weights obtained from the learning process of the neural networks previously. To prove the reasonableness, the selected compliance automatic robot arm type direct drive robot and anthropomorphic robot are simulated. It shows that the proposed calibration method can reduce the errors of the joint variables from ${\pm}$0.15$^{\circ}$to ${\pm}$0.12$^{\circ}$.

  • PDF

A Parasitic Elements Extraction of the Distributed Elements and an Application of the BPF Using the Short-Open Calibration Method (단락 개방 Calibration 방법을 이용한 분포 정수 소자의 기생 소자 추출 및 대역 통과 필터에의 응용)

  • Kim, Yu-Seon;Nam, Hun;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.115-123
    • /
    • 2009
  • In this paper, we extract the parasitic elements of the transmission line with the defected ground structure(DGS) and the short-circuited comb line section using the Short-Open Calibration(SOC). The scattering matrixes of short, open and the distributed elements in microstrip line are measured by full electro-magnetic(EM) simulator and Vector Network Analyser(VNA). The electro-magnetic effects of the proposed structures are considered by the II and T equivalent circuits with frequency independent elements, and the relations between the measured scattering parameters and the elements in the circuits are shown by performing 2 port network analysis. Moreover, to design the 2.4 GHz bandpass filter with second order butterworth prototype, the proposed methods are applied. As results, the measured $S_{11}$ and $S_{21}$ indicate -20 dB and -1.3 dB at center frequency, and these are shown within 5 % error compare to the predicted results at $0.5{\sim}5\;GHz$.

A Parasitic Elements Extraction of MIM Capacitor Using Short-Open Calibration Method (단락 개방 Calibration 방법을 이용한 MIM 커패시터의 기생 소자 값 추출)

  • Kim, Yu-Seon;Nam, Hun;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.114-120
    • /
    • 2008
  • In this paper, we extract the parasitic elements of the metal-insulate-metal(MIM) capacitor using short-open calibration (SOC). The scattering matrixes of short, open, and MIM structures in strip lines are measured by full electro-magnetic (EM) simulator and vector network analyser. The full EM simulations are performed by finite element method (FEM) that was fitted three dimensional structure analysis. The electro-magnetic effects of MIM capacitor laminated in the multi-layered structures are proposed the II equivalent circuit with lumped elements, and the relations between the measured scattering parameters of the MIM structures and lumped elements in the circuits are shown by performing 2 port network analysis. The extracted lumped elements using the proposed SOC method are independent to frequencies.

A Study on RF Calibration Method of Next Generation Mobile Communication System (차세대 이동통신 시스템의 RF Calibration 기법에 관한연구)

  • Kim, Wan-Tae;Cho, Sung-Joon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.859-864
    • /
    • 2010
  • In the next generation system, a study on realization of Multi-Core system is in progress for applying it in multi service network. Therefore some mobile systems are expected to be appeared. These systems can support WiBro, WCDMA, CDMA, etc with single terminal. These systems have to support various FA using broadband frequency and hand over to other service network. Especially, in the telecommunication system composed of cell, the transmit power can be interference at adjacent system, has effect on system channel capacity and cell size. In this paper, we improve the unstable transmit power caused by unsettled system operation, propose the RF(Radio Frequency) Calibration method which can use the transmit power stably even during hand over between heterogeneous networks causing unstable power change. Also we used proposed method and analysed used electricity of system during hand over between heterogeneous networks.

Calibration of a Network Link Travel Cost Function with the Harmony Search Algorithm (화음탐색법을 이용한 교통망 링크 통행비용함수 정산기법 개발)

  • Kim, Hyun Myung;Hwang, Yong Hwan;Yang, In Chul
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.5
    • /
    • pp.71-82
    • /
    • 2012
  • Some previous studies adopted a method statistically based on the observed traffic volumes and travel times to estimate the parameters. Others tried to find an optimal set of parameters to minimize the gap between the observed and estimated traffic volumes using, for instance, a combined optimization model with a traffic assignment model. The latter is frequently used in a large-scale network that has a capability to find a set of optimal parameter values, but its appropriateness has never been demonstrated. Thus, we developed a methodology to estimate a set of parameter values of BPR(Bureau of Public Road) function using Harmony Search (HS) method. HS was developed in early 2000, and is a global search method proven to be superior to other global search methods (e.g. Genetic Algorithm or Tabu search). However, it has rarely been adopted in transportation research arena yet. The HS based transportation network calibration algorithm developed in this study is tested using a grid network, and its outcomes are compared to those from incremental method (Incre) and Golden Section (GS) method. It is found that the HS algorithm outperforms Incre and GS for copying the given observed link traffic counts, and it is also pointed out that the popular optimal network calibration techniques based on an objective function of traffic volume replication are lacking the capability to find appropriate free flow travel speed and ${\alpha}$ value.

Development of a Multi-Site Calibration Module of Distributed Model - The Case of GRM - (분포형 모형의 다지점 보정 모듈 개발 - GRM 모형을 중심으로 -)

  • Choi, Yun-Seok;Choi, Cheon-Kyu;Kim, Kyung-Tak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.3
    • /
    • pp.103-118
    • /
    • 2012
  • A distributed model can easily obtain discharge at any grids spatially distributed in a watershed. But if there are subwatersheds which have various characteristics in a watershed, it is needed to apply a model calibrated at each subwatershed to obtain reliable simulation results for each subwatershed. In this study, a multi-site calibration module that can calibrate a distributed model at each subwatershed using observed flow data was developed. Methods to select multi-site calibration parameters, to apply subwatershed parameters, and to set subwatershed network information are suggested. Classes to implement multi-site calibration technique are designed and a GUI was developed, and procedures for runoff modelling using subwatershed parameters were established. Multi-site calibration module was applied to Sunsan watershed($977km^2$) of Nakdong river basin. Application results showed that the multi-site calibration technique could be applied effectively to model the calibration for each subwatershed, and the simulation results of subwatershed were improved by the application of multi-site calibration.

FVT Signal Processing for Structural Identification of Cable-stayed Bridge (사장교의 구조식별을 위한 가진실험 데이터분석)

  • 이정휘;김정인;윤자걸
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.923-929
    • /
    • 2004
  • In this research, Forced Vibration Test(FVT) on a cable stayed bridge was conducted to examine the validity of the frequency domain pattern recognition method using signal anomaly index and artificial neuralnetwork. 7he considering structure, Samchunpo Bridge, located in Sachun-Shi, Kyungsangnam-Do, is a cable stayed bridge with the 436 meter span. The excitation force was induced by a sudden braking of a fully loaded truck. and vortical acceleration signals were acquired at 14 points. The initial 2-dimensional FE-model was developed from the design documents to prepare the training sets for the artificial neural network, and then the model calibration was performed with the field test data. As a result of the model calibration, we obtained the FFT spectrums from the model simulation, which was similar to those from the vibration test. These tests and the simulation data will be used for the structural identification using arbitrarily added masses to the bridge.

Calibration of frequency propagation channel sounder based on five-port reflectometer

  • Yem Van;Braga Judson;Huyart B;Begaud X;de Sousa F.R;Huyen Nguyen Bich
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.23-26
    • /
    • 2004
  • Five-port reflectometer which consists of a ring with 5 arms (two inputs, three outputs) and three RF power detectors has been used as a vector network analyser, a demodulator in the homodyne receiver as well as in Phase Looked Loop (PLL) and so on. Calibration of five-port reflectometer is an important task. In this paper, we present a calibration method of five-port for a propagation channel sounder. The method is based on measurement of the phase differences between the three voltages at the five-port's outputs in order to determine the ratio of two input incident waves. The frequency channel sounder based on five-port is calibrated for each frequency from 2.2 GHz to 2.6 GHz with 1 MHz step. This method can also determine the absolute delays of each propagation path in the propagation channel. The calibration method is validated using measurement data.

  • PDF

Support of Automatic Calibration for Computerized Puretone Audiometer Using Linux Real-time Spectrum Analyzer (리눅스 실시간 스펙트럼 분석기를 이용한 컴퓨터 기반 순음청력검사 시스템의 자동 보정 지원)

  • Lee, Seung-Hee;Shin, Bum-Joo;Song, Bok-Deuk;Kim, Jin-Dong;Jeon, Gye-Rok;Wang, Soo-Geon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.837-843
    • /
    • 2012
  • Compared to conventional pure-tone audiometer(PTA), the computerized one has several advantages such as relatively lower price, better flexibility, and easy operation. In addition, the computerized PTA can be easily extended to support automatic calibration. In this study, the support of automatic calibration in the computerized PTA has been addressed using the Linux realtime spectrum analyzer and network. In terms of accuracy, the new automatic calibration machine was compared to the existing manually operated one. According to the comparison, normal operation and high accuracy were observed within the scope of the international standard.