• 제목/요약/키워드: Nerve gas

검색결과 31건 처리시간 0.021초

Nerve Agents and Their Detection

  • Kim, Young Jun;Huh, Jae Doo
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.217-223
    • /
    • 2014
  • Nerve agents are major chemical warfare agents with the "G series" and "V series" being the most widely known because of their lethal effect. Although not conspicuously used in major wars, the potential detrimental impact on modern society had been revealed from the sarin terror attack on Tokyo subway, which affected thousands of people. In this mini-review, major nerve agents of the "G series" and "V series" have been described along with various types of their detection methods. The physical properties and hydrolysis mechanisms of the major nerve agents are discussed since these are important factors to be considered in choosing detection methods, and specifying the procedures for sample preparations in order to enhance detection precision. Various types of extraction methods, including liquid-phase, solid-phase, gas-phase and solid-phase microextraction (SPME), are described. Recent development in the use of gas sensors for detecting nerve agents is also summarized.

산화주석을 기반으로 한 DMMP 후막가스센서 제작 (fabrication of DMMP Thick Film Gas Sensor Based on SnO2)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1217-1223
    • /
    • 2003
  • Nerve gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas is dimethyl methyl phosphonate(C$_3$ $H_{9}$ $O_3$P, DMMP) that is simulant gas of nerve gas. Sensing materials were Sn $O_2$ added a-Al$_2$ $O_3$ with 0∼20wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor device was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Total size of device was 7${\times}$10${\times}$0.6㎣. Crystallite size & phase identification and morphology of fabricated Sn $O_2$ powders were analyzed by X-ray diffraction and by a scanning electron microscope, respectively. Fabricated sensor was measured as flow type and resistance change of sensing material was monitored as real time using LabVIEW program. The best sensitivity was 75% at adding 4wt.% $\alpha$-Al$_2$ $O_3$, operating temperature 30$0^{\circ}C$ to DMMP 0.5ppm. Response and recovery time were about 1 and 3min., respectively. Repetition measurement was very good with $\pm$3% in full scale.TEX>$\pm$3% in full scale.

신경작용제 분해효소의 Soman 및 Sarin Gas 분해 능력 측정 및 제독응용 가능성 (Test of Degradation of Soman and Sarin Gas by Organophosphorus Acid Anhydrolase and Applicability of the Enzyme to the Development of Nerve Agent Decontaminant)

  • 김석찬;이남택
    • 한국군사과학기술학회지
    • /
    • 제2권2호
    • /
    • pp.140-147
    • /
    • 1999
  • A gene expressing organophosphorus acid (OPA) anhydrolases have been cloned from Alteromonas haloplanktis strain and expressed in bacterial strain BL21. Crude extract was prepared from the transformed bacterial strain BL2l and used in testing its degrading capability of real nerve gas, soman and sarin. Within 1 minute after the start of the reaction, nearly 65% of the soman added to the reactant(3mM) was degraded by adding 1 mg of the crude extract enzyme(20.0 Unit $mg^-{1}$ crude protein). In 6 minutes, the reaction reached at its steady state, which indicates that soman was completely degraded by that time. In the case of sarin, the degradation efficiency was observed to be about 0.7 times of that of soman. If the specific activity of OPAA is enhanced by both increased expression efficiency and purification, OPAA seems to be applied for the development of decontaminant of skin, especially of eye.

  • PDF

Gas-Filled Intradural Cyst within the Cauda Equine

  • Cho, Hyung-Lea;Lee, Sang-Ho;Kim, Jin-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권3호
    • /
    • pp.182-185
    • /
    • 2011
  • A case of radicular pain that resulted from a gas-filled intradural cyst in an 80-year-old male is described. Temporary improvement of radicular pain was observed after CT-guided aspiration. However, recurrent radicular pain led to surgical treatment. In this report, the authors document the radiologic and intraoperative features of a gas-filled intradural cyst that migrated into the nerve root, and propose an optimal treatment plan based on a review of the literature.

개흉술후 벽측흉막외 신경차단법에 의한 진통효과 (Post-thoracotomy pain control with paravertebral intercostal nerve block)

  • 임창영;김요한
    • Journal of Chest Surgery
    • /
    • 제26권10호
    • /
    • pp.781-786
    • /
    • 1993
  • Effrctive analgesia after elective thoracotomy can be provided by continuous extrapleural intercostal nerve block.This study was designed to prove the effectiveness of continuous extrapleural intercostal nerve block. Twenty patients undergoing elective thoracotomy were randomized into two groups. Group I received lumbar epidural block[N=10] and group II received continuous extrapleural intercostal nerve block[N=10]. Postoperative pain relief was assessed on Numeric Rating Scale[NRS] and recovery of pulmonary function was assessed by coparison of preoperatrive and postoperative FVC[Forced Vital Capacity], FEV1[Forced expiratory Volume in 1 second], VC[Vital Capacity]. Arterial blood gas analysis[ABGA], vital signs and amount of additive analgesics were compared also. No significant difference was observed between the groups concerning these parameters mentioned above. Systemic complications, such as urinary retention[2/10] and weakness of lower extremity[2/10], occurred in group I but no complication occurred in group II. We conclude that continuous extrapleural intercostal nerve block is as effective as epidural block in pain relief and restoration of pulmonary mechanics with fewer comlications. Also because of it`s ease and safetiness, this must be considered as a substitute of epidural block in routine use for thoracotomy pain relief.

  • PDF

PAN계 활성탄소섬유의 미세기공 구조가 신경작용제 유사가스(DMMP) 감응 특성에 미치는 영향 (Influence of the Micropore Structures of PAN-based Activated Carbon Fibers on Nerve Agent Simulant Gas (DMMP) Sensing Property)

  • 강다희;김민지;조한주;최예지;이영석
    • 공업화학
    • /
    • 제29권2호
    • /
    • pp.191-195
    • /
    • 2018
  • 본 실험에서는 활성탄소섬유의 미세기공구조가 신경작용제 유사가스인 dimethyl methylphosphonate (DMMP) 감응 특성에 미치는 영향을 고찰하였다. 탄소섬유에 화학적 활성화법을 이용하여 기공구조를 부여하였고, 이를 이용하여 가스센서용 전극을 제조하였다. N형 반도체인 polyacrylonitrile (PAN)계 활성탄소섬유 기반 전극은 환원성 가스인 DMMP로부터 전자를 받아 정공의 밀도 감소로 인하여 전기저항이 감소하게 되었다. DMMP 가스센서의 민감도는 미세기공 부피가 증가함에 따라 1.7%에서 5.1%까지 증가하였다. 이는 분자 크기가 0.57 nm인 DMMP를 흡착하기에 적합한 미세기공이 형성됨에 따라, DMMP와 활성탄소섬유간의 전자 이동이 용이해졌기 때문이라 사료된다. 결론적으로, 높은 감도의 DMMP 가스센서를 제조하기 위해서는 적절한 기공구조 조절이 중요한 역할을 한다고 판단된다.

산화주석을 기반으로 한 DMMP 가스센서 제작 (Fabrication of DMMP gas sensor based on $SnO_2$)

  • 최낙진;반태현;백원우;이우석;김재창;허증수;이덕동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.942-945
    • /
    • 2003
  • Nerve gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas was dimethylmethylphosphonate($C_3H_9O_3P$, DMMP) that is simulant gas of nerve gas. Sensing material was $SnO_2$ added ${\alpha}-Al_2O_3$ with $4{\sim}20wt.%$ and was physically mixed. And then it was deposited by screen printing method on alumina substrate. Sensor device was consisted of sensing electrode with interdigit(IDT) type in front and heater in back side. Total size of device was $7{\times}10{\times}0.6mm^3$. Crystallite size of fabricated $SnO_2$ were characterized by X-ray diffraction(XRD, Rigaku) and morphology of the $SnO_2$ powders was observed by a scanning electron microscope(SEM, Hitachi). Fabricated sensor was measured as flow type and sensor resistance change was monitored real time using LabVIEW program. The best conditions as added $Al_2O_3$ amounts and operating temperature changes were 4wt.% and $300^{\circ}C$ in DMMP 0.5ppm, respectively. The sensitivity was over 75%. Response and recovery times were about 1 and 3 min., respectively. Repetition measurement was very good with ${\pm}3%$ in full scale.

  • PDF

Radicular Compression by Intraspinal Epidural Gas Bubble Occurred in Distant Two Levels after Lumbar Microdiscectomy

  • Lee, Chul-Woo;Yoon, Kang-Jun;Ha, Sang-Soo;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권6호
    • /
    • pp.521-526
    • /
    • 2014
  • The authors report a case of symptomatic epidural gas accumulation 2 weeks after the multi-level lumbar surgery, causing postoperative recurrent radiculopathy. The accumulation of epidural gas compressing the dural sac and nerve root was demonstrated by CT and MRI at the distant two levels, L3-4 and L5-S1, where vacuum in disc space was observed preoperatively and both laminectomy and discectomy had been done. However, postoperative air was not identified at L4-5 level where only laminectomy had been done in same surgical field, which suggested the relationship between postoperative epidural gas and the manipulation of disc structure. Conservative treatment and needle aspiration was performed, but not effective to relieve patient's symptoms. The patient underwent revision surgery to remove the gaseous cyst. Her leg pain was improved after the second operation.

DMMP 검출용 금속산화물을 첨가한 $SnO_2$ 가스센서 제조 (Fabrication of $SnO_2$ Gas Sensor added by Metal Oxide for DMMP)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • 한국군사과학기술학회지
    • /
    • 제6권3호
    • /
    • pp.54-61
    • /
    • 2003
  • $SnO_2$ gas sensor for the detection DMMP, simulant of nerve gas was fabricated and its characteristics were examined. Sensing materials were $SnO_2$ added by TEX>$\alpha$-$Al_{2}O_{3}$ with 0∼20wt.% and $In_{2}O_{3}$ with 0∼3wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Its dimension was 7$\times$10$\times$0.6$\textrm{mm}^2$. Crystallite size 8t phase identification, specific surface area and morphology of fabricated $SnO_2$ powders were analyzed by X-ray diffraction(XRD), surface area analyzer(BET) and by a scanning electron microscope(SEM), respectively. Sensor was measured as flow type and sensor resistance change was monitored as real time using LabVIEW program. The best sensitivities were 75% at adding 4wt.% TEX>$\alpha$-$Al_{2}O_{3}$, operating temperature $300^{\circ}C$ and 87% at adding 2wt.% $In_{2}O_{3}$, operating temperature $350^{\circ}C$ to DMMP 0.5ppm. Response and recovery times were about 1 and 3 min., respectively. Repetition measurement was very good with $\pm$3% in full scale. As a result, operating temperature was lower TEX>$\alpha$-$Al_{2}O_{3}$ than $In_{2}O_{3}$, but sensitivity was higher $In_{2}O_{3}$ than $\alpha$-$Al_{2}O_{3}$.

Micro-Spot Atmospheric Pressure Plasma Production for the Biomedical Applications

  • Hirata, T.;Tsutsui, C.;Yokoi, Y.;Sakatani, Y.;Mori, A.;Horii, A.;Yamamoto, T.;Taguchi, A.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.44-45
    • /
    • 2010
  • We are currently conducting studies on culturing and biocompatibility assessment of various cells such as neural stem cells and induced pluripotent stem cells(IPS cells) on carbon nanotube (CNT), on nerve regeneration electrodes, and on silicon wafers with a focus on developing nerve integrated CNT based bio devices for interfacing with living organisms, in order to develop brain-machine interfaces (BMI). In addition, we are carried out the chemical modification of carbon nanotube (mainly SWCNTs)-based bio-nanosensors by the plasma ion irradiation (plasma activation) method, and provide a characteristic evaluation of a bio-nanosensor using bovine serum albumin (BSA)/anti-BSA binding and oligonucleotide hybridization. On the other hand, the researches in the case of "novel plasma" have been widely conducted in the fields of chemistry, solid physics, and nanomaterial science. From the above-mentioned background, we are conducting basic experiments on direct irradiation of body tissues and cells using a micro-spot atmospheric pressure plasma source. The device is a coaxial structure having a tungsten wire installed inside a glass capillary, and a grounded ring electrode wrapped on the outside. The conditions of plasma generation are as follows: applied voltage: 5-9 kV, frequency: 1-3 kHz, helium (He) gas flow: 1-1.5 L/min, and plasma irradiation time: 1-300 sec. The experiment was conducted by preparing a culture medium containing mouse fibroblasts (NIH3T3) on a culture dish. A culture dish irradiated with plasma was introduced into a $CO_2$-incubator. The small animals used in the experiment involving plasma irradiation into living tissue were rat, rabbit, and pick and are deeply anesthetized with the gas anesthesia. According to the dependency of cell numbers against the plasma irradiation time, when only He gas was flowed, the growth of cells was inhibited as the floatation of cells caused by gas agitation inside the culture was promoted. On the other hand, there was no floatation of cells and healthy growth was observed when plasma was irradiated. Furthermore, in an experiment testing the effects of plasma irradiation on rats that were artificially given burn wounds, no evidence of electric shock injuries was found in the irradiated areas. In fact, the observed evidence of healing and improvements of the burn wounds suggested the presence of healing effects due to the growth factors in the tissues. Therefore, it appears that the interaction due to ion/radicalcollisions causes a substantial effect on the proliferation of growth factors such as epidermal growth factor (EGF), nerve growth factor (NGF), and transforming growth factor (TGF) that are present in the cells.

  • PDF