• 제목/요약/키워드: Negative shift

검색결과 306건 처리시간 0.025초

Validity of Breast Cancer Symptom Questionnaire and Its Relationship With Breast Ultrasonography in Young Female Night Workers

  • Chae, Chang-Ho
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.361-366
    • /
    • 2020
  • Background: This study aimed to identify the validity of breast cancer symptom questionnaire of worker's special health examination and its relationship with breast ultrasonography findings in young female night workers. Methods: The breast cancer symptom questionnaire data of worker's special health examination and breast ultrasonography results in young female shift workers who worked in one electronic manufacture company were collected from 2014 to 2018. Results: Of the 857 workers, 18 had a Breast Imaging Reporting and Database System category 4 or higher. Among other variables, shift work tenure alone was associated with the risk of having a Breast Imaging Reporting and Database System category higher than 4. The sensitivity, specificity, positive predictive value, and negative predictive value of the symptom questionnaire were 16.7%, 87.7%, 2.8%, and 98.0%, respectively. Conclusion: The current breast cancer symptom questionnaire of the worker's special health examination is inappropriate due to its low sensitivity and positive predictive value. In the future, female night workers will need alternative measures for more accurate screening for breast cancer.

수평 배향된 네마틱 액정 모드들의 화질 특성 비교 (Comparisons of Image Quality Characteristics in Homogeneously Aligned Nematic Liquid Crystal Modes)

  • 정병선;김태현;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.100-103
    • /
    • 2005
  • Homogeneously aligned nematic liquid crystal modes are representatively the -FFS (fringe-field switching) mode using liquid crystal (-LC) with negative dielectric anisotropy, the +FFS mode and the IPS (in-plane switching) mode using +LC with positive dielectric anisotropy. In view of image quality evaluation standard of LCD, we compared characteristics of the brightness, the contrast ratio (CR) and color shift when the modes have respectively optimized phase retardation values $(d{\Delta}n)$. Consequently, in the most sensitively viewing angle of a man's physical vision, both FFS modes have advantage over the IPS mode from the brightness & the CR point of view. We are also confirmed that the +FFS mode out of them shows the smallest color shift according to all viewing directions in grey levels.

  • PDF

POSSIBLE MERGER SIGNATURE IN SZ MAPS

  • KOCH PATRICK
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.471-476
    • /
    • 2004
  • We propose an analytical model to estimate the influence of a merger on the thermal SZ effect. Following observations we distinguish between subsonic and transonic mergers. Using analytical velocity fields and the Bernoulli equation we calculate the excess pressure around a moving subcluster for an incompressible subsonic gas. Positive excess around the stagnation point and negative excess on the side of the subcluster lead to characteristic signatures in the SZ map, of the order of $10\%$ compared to the unperturbed signal. For a transonic merger we calculate the change in the thermal spectral SZ function, resulting from bow shock accelerated electrons. The merger shock compression factor determines the power law tail of the new non-thermal electron population and is directly related to a shift in the crossover frequency. This shift is typically a few percent towards higher frequencies.

Degradation of Ferroelectric Properties of Pt/PZT/Pt Capacitors in Hydrogen-containing Environment

  • Kim, Dong-Chun;Lee, Won-Jong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권5호
    • /
    • pp.214-220
    • /
    • 2005
  • The ferroelectric properties of the $Pt/PZT(Pb(Zr,Ti)O_3)/Pt$ capacitors are severely degraded when they are annealed in hydrogen-containing environment. Hydrogen atoms created by the catalytic reaction of Pt top electrode during annealing in hydrogen ambient penetrate into PZT films and generate oxygen vacancies by the reduction of the PZT films, which is likely to cause the degradation. The degree of hydrogen-induced degradation and the direction of voltage shift in P-E curves of the pre-poled PZT capacitors after annealing in hydrogen ambient is dependent on the polarity of the pre-poling voltage. This implies that oxygen vacancies causing hydrogen induced degradation are generated by hydrogen ions having a polarity. The degraded ferroelectricity of the PZT capacitors can be effectively recovered by the shift of oxygen vacancies toward the Pt top electrode interface during post-annealing in oxygen environment with applying negative unipolar stressing.

Bias stress effect in organic thin-film transistors with cross-linked PVA gate dielectric and its reduction method using $SiO_2$ blocking layer

  • Park, Dong-Wook;Lee, Cheon-An;Jung, Keum-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.445-448
    • /
    • 2006
  • Bias stress effect in pentacene organic thin-flim transistors with cross-linked PVA gate dielectric is analyzed. For negative gate bias stress, positive threshold voltage shift is observed. The injected charges from the gate electrode to the defect states of gate dielectric are regarded as the main origin of $V_T$ shift. The reduced bias stress effect using $SiO_2$ blocking layer confirms the assumed mechanism. It is also demonstrated that the inverter with $SiO_2$ blocking layer shows the negligible hysteresis owing to the reduced bias stress effect.

  • PDF

Bactericidal Activity of Grapefruit (Citrus paradisl) Seed Extract-Based Disinfectant

  • Han, Jae-Hong;Kim, Yong-Ung;Kim, Ki-Yeon;Hahm, Young-Tae
    • Journal of Applied Biological Chemistry
    • /
    • 제49권3호
    • /
    • pp.90-94
    • /
    • 2006
  • Bactericidal activity of grapefruit seed extract (GSE)-based disinfectant, as a safe disinfectant, was measured against five bacteria by Korean Food & Drug Administration (KFDA) dilution-neutralization method. GSE-based disinfectant showed a 99.9999% bactericidal activity against Escherichia coli ATCC 10536, Salmonella typhi ATCC 29629, Staphylococcus aureus ATCC 6538, Bacillus cereus ATCC 11778, and Listeria monocytogenes ATCC 1911 at the concentration of 2.15% GSE. It showed better bactericidal activity against Gram-negative bacteria of E. coli ATCC 10536 and S. typhi ATCC 29629 at lower concentration of GSE (0.43%). Based on the results, it was suggested that a possible bactericidal mechanism of GSE active ingredients was due to the abrupt osmotic shift during the bactericidal activity test by KFDA method.

Characteristics of the Multi-Hydrogen Bonded Systems: DFT Description on the Solvated Electrons

  • Xu, Jun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3265-3268
    • /
    • 2013
  • The multi-hydrogen bonded systems with the solvated electrons are investigated at the B3LYP/6-311++$G^{**}$ basis set level. The symmetrical linear geometrical characteristic is common for the dimer systems, while for the tetramer system, the tetrahedron configuration is generated. The NBO charge analyses demonstrate that the multi-hydrogen-multi-electron (mH-ne) coupling exist in these anion systems, as is supported by the electrostatic potential and the molecular orbital analyses. The positive chemical shift value of the central hydrogen ($H_c$) and the negative chemical shift value of the terminal hydrogen ($H_t$) indicate that the $H_c$ is electronegative while the $H_t$ is electropositive, respectively. Strong coupling between two central hydrogen atoms is demonstrated by the large spin-spin coupling constants. The solvated electron donates significant contributions for the stability of these systems.

XPS STUDY ON SN-DOPED DLC FILMS PREPARED BY RF PLASMA-ENHANCED CVD

  • Inoue, Y.;Komoguchi, T.;Nakata, H.;Takai, O.
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.519-524
    • /
    • 1996
  • We synthesized semiconducting Sn-doped diamondlike carbon films by rf plasma-enhanced chemical vapor deposition using an organotin compound as a dopung gas source. XPS quan-titative analysis for the deposited films after 60 s argon ion etching revealed that Sn concen-tration increased with the partial pressure of the organotin compound in the reactant gas. In C 1s spectra, there was a component due to C-Su bond which had a negative chemical shift. C 1s spectra also indicated that the deposited films were relatively $sp^2$ rich. The chemical shift of the Sn-C bond in Sn $3d_{5/2}$ spectra was about +1.7 eV. The electrical resistivity and the optical transmittance were also investigated.

  • PDF

교대근무가 음주에 미치는 영향 및 수면의 매개효과 (The Effect of the Shift Work on Drinking and the Mediating Effect of Sleep)

  • 정희주;공지숙;김미경;김석현
    • 정신신체의학
    • /
    • 제29권2호
    • /
    • pp.111-120
    • /
    • 2021
  • 연구목적 이전 연구에 따르면 교대근무는 인간의 자연적인 일주기 리듬에 적응하기 어렵게 만들어 각종 건강문제를 일으킨다. 특히 교대근무자는 근무 일정과 연관된 수면의 어려움을 호소하는 경향이 있으며, 알코올을 수면유도를 위한 자가약으로 사용하는 경우가 있다. 현재까지 교대근무와 수면 및 음주와의 관련성에 관한 명확한 기전이 밝혀지지 않고 있는 상태이다. 따라서 이 연구에서는 교대근무와 수면과의 관련성을 확인하고, 교대근무로 인한 수면의 변화가 음주를 유발하는지에 대해 분석하고자 한다. 방 법 이 연구는 국민건강영양조사 제6기, 제7기 자료 중 2014, 2016, 2018년도를 분석대상으로 하였으며 총 11360명(남성 5704명, 여성 5656명)을 연구대상인원으로 포함시켰다. 6 am-6 pm사이의 근무형태를 주간근무, 이외의 근무형태를 교대근무로 정의하였으며 로지스틱 회귀분석을 통하여 교대근무와 수면의 질, 교대근무와 고위험 음주, 음주량 및 음주 횟수의 관계를 분석하였다. 또한 매개분석을 통하여 수면이 교대근무와 음주의 관계를 매개하는지 여부를 분석하였다. 결 과 교대근무는 남성과 여성에서 수면 질과 유의한 음의 관계를 보였다(남성 OR=1.37, 95% CI=1.11-1.70, 여성 OR=1.26, 95% CI=1.05-1.50). 교대근무와 음주와의 관계에서는 남성의 경우 유의한 관계가 나타나지 않았으나, 여성의 경우 교대근무와 음주횟수에서 유의한 양의 관계를 보였다(OR=1.34, 95% CI=1.04-1.72). 매개분석 시행 시 여성의 수면 질은 교대근무와 음주횟수의 관계를 부분매개하는 것으로 나타났다. 결 론 이 연구의 결과는 교대근무가 수면의 어려움을 유발하며, 여성의 경우에서는 수면의 부분매개효과를 통해 음주를 유발할 수 있음을 시사한다. 여성이 수면장애에 대한 대처방안으로 음주를 선택할 가능성이 높은 점을 고려할 때, 여성 교대근무자에 대한 보다 적극적인 중재방안이 마련된 필요가 있다.

The effect of negative bias stress stability in high mobility In-Ga-O TFTs

  • Jo, Kwang-Min;Sung, Sang-Yun;You, Jae-Lok;Kim, Se-Yun;Lee, Joon-Hyung;Kim, Jeong-Joo;Heo, Young-Woo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.154-154
    • /
    • 2013
  • In this work, we investigated the characteristics and the effects of light on the negative gate bias stress stability (NBS) in high mobility polycrystalline IGO TFTs. IGO TFT showed a high drain current on/off ratio of ${\sim}10^9$, a field-effect mobility of $114cm^2/Vs$, a threshold voltage of -4V, and a subthresholdslpe(SS) of 0.28V/decade from log($I_{DS}$) vs $V_{GS}$. IGO TFTs showed large negative $V_{TH}$ shift(17V) at light power of $5mW/cm^2$ with negative gate bias stress of -10V for 10000seconds, at a fixed drain voltage ($V_{DS}$) of 0.5V.

  • PDF