• Title/Summary/Keyword: Negative resonance

Search Result 311, Processing Time 0.027 seconds

Resonance tunneling phenomena by periodic potential in type-II superconductor

  • Lee, Yeong Seon;Kang, Byeongwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • We calculated the resonance tunneling energy band in the BCS gap for Type-II superconductor in which periodic potential is generated by external magnetic flux. In this model, penetrating magnetic flux was assumed to be in a fixed lattice state which is not moving by an external force. We observed the existence of two subbands when we used the same parameters as for the $Nd_{1.85}Ce_{0.15}CuO_X$ thin film experiment. The voltages at which the regions of negative differential resistivity (NDR) started after the resonant tunneling ended were in a good agreement with the experimental data in the field region of 1 T - 2.2 T, but not in the high field regions. Discrepancy occurred in the high field region is considered to be caused by that the potential barrier could not be maintained because the current induced by resonant tunneling exceeds the superconducting critical current. In order to have better agreement in the low field region, more concrete designing of the potential rather than a simple square well used in the calculation might be needed. Based on this result, we can predict an occurrence of the electromagnetic radiation of as much difference of energy caused by the 2nd order resonant tunneling in which electrons transit from the 2nd band to the 1st band in the potential wells.

Backbone NMR Assignments of an Uncharacterized Protein, SF1002 from Shigella flexneri 5a M90T

  • Lee, Yoo-Sup;Yoon, Won-Su;Chung, Il;Chung, Ka Young;Won, Hyung-Sik;Seo, Min-Duk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.1
    • /
    • pp.36-41
    • /
    • 2015
  • The causative agent of shigellosis, Shigella flexneri, is a Gram-negative anaerobic bacterial pathogen that causes one of the most infectious bacterial dysenteries in humans. It originates infection by invading cells of the colonic epithelium using a type III secretion system. Despite S. flexneri is closely linked with the human disease, structural study is very deficient. Here, we have initiated NMR study of SF1002 which is the uncharacterized protein from S. flexneri strain 5a M90T. Based on a series of triple resonance spectra, sequence-specific assignments of the backbone amide resonances of SF1002 could be completed. This NMR study would contribute to the structural genomics of S.flexneri.

Backbone Resonance Assignment of a Proteolysis-Resistant Fragment in the Oxygen-Dependent Degradation Domain of the Hypoxia Inducible Factor 1α

  • Kim, Do-Hyoung;Lee, Si-Hyung;Chi, Seung-Wook;Nam, Ki Hoon;Han, Kyou-Hoon
    • Molecules and Cells
    • /
    • v.27 no.4
    • /
    • pp.493-496
    • /
    • 2009
  • Hypoxia-inducible factor $1{\alpha}$ ($HIF1{\alpha}$) is a transcription factor that plays a key role in the adaptation of cells to low oxygen stress and oxygen homeostasis. The oxygen-dependent degradation (ODD) domain of $HIF1{\alpha}$ responsible for the negative regulation of $HIF1{\alpha}$ in normoxia is intrinsically unfolded. Here, we carried out the backbone $^1H$, $^{15}N$, and $^{13}C$ resonance assignment of a proteolysis-resistant fragment (residues 404-477) in the $HIF1{\alpha}$ ODD domain using NMR spectroscopy. About 98% (344/352) of all the $^1HN$, $^{15}N$, $^{13}C{\alpha}$, $^{13}C{\beta}$, and $^{13}CO$ resonances were unambiguously assigned. The results will be useful for further investigation of the structural and dynamic states of the $HIF1{\alpha}$ ODD domain and its interaction with binding partners.

Design of 9 kJ/s High Voltage LiPo Battery based 2-stage Capacitor Charger (배터리 기반 2단 충전 9 kJ/s 고전압 충전기 설계)

  • Cho, Chan-Gi;Jia, Ziyi;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.268-272
    • /
    • 2019
  • A lithium polymer battery-based 9 kJ/s high-voltage capacitor charger, which comprises two stages, is proposed. A modified LCC resonant converter and resonant circuit are introduced at the first and second stages, respectively. In the first stage, the methods for handling low-voltage and high-current batteries are considered. Delta-wye three-phase transformers are used to generate a high output voltage through the difference between the phase and line-to-line voltages. Another method is placing the series resonant capacitor of the LCC resonant components on the transformer secondary side, which conducts considerably low current compared with the transformer primary side. On the basis of the stable operation of the first charging stage, the secondary charging stage generates final output voltage by using the resonance. This additional stage protects the rectifying diodes from the negative voltage when the output capacitor is discharged for a short time. The inductance and capacitance of the resonance components are selected by considering the resonance charging time. The design procedure for each stage with the aforementioned features is suggested, and its performance is verified by not only simulation but also experimental results.

The Study of Lipid Proton Composition Change in a Rat Model of High Fat Diet Induced Fatty Liver by Magnetic Resonance Spectroscopy Analysis (고지방식이 유도성 지방간 쥐 모델에서 간의 자기공명분광 분석을 이용한 지질 양성자 조성 변화 연구)

  • Kim, Sang-Hyeok;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.315-325
    • /
    • 2021
  • The purpose of this study is to investigate the changes in lipid proton (LP) composition according to the induced obese fatty liver and to use it as basic data for treatment and diagnosis of fatty liver in the future. The phantom study was conducted to identify differences between STEAM and PRESS Pulse sequences in LP concentration. A high-fat diet (60%) was administered to eight Sprague-Dawley rats to induce obesity and fatty liver disease. Baseline magnetic resonance imaging /spectroscopy data were obtained prior to the introduction of high-fat diet, and data acquisition experiments were performed after eight weeks using procedures identical to those used for baseline studies. The six lipid proton metabolites were calculated using LCModel software. The correlation between the fat percentage and each LP, revealed that the methylene protons at 1.3 ppm showed the highest positive correlation. The α-methylene protons to carboxyl and diallylic protons showed negative correlation with fat percentage. The methylene proton showed the highest increase in the LP; however, it constituted only 71.86% of the total LP concentration. The methylene proton plays a leading role in fat accumulation in liver parenchyma.

The Accurate design of a Temperature stable Dielectric Stepped-Impedance Resonator (온도 변화에 안정한 유전체 Stepped-Impedance Resonator의 정확한 설계)

  • 임상규;김덕환안철
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.625-628
    • /
    • 1998
  • This paper presents the design method of a temperature stable stepped-impedance resonator using composite material. In this method temperature coefficient of dielectric constant $(\tau\varepsilon)$ and thermal expansion coefficient $(\alpha1)$ of dielectric material were considered. Ba(Zn1/3Nb2/3)O3 and CaZrO3 as composite material having opposite signs of temperature coefficient of dielectric constant were selected. The length of this resonator for the temperature stability of resonance frequency was calculated at 900MHz, 1.4㎓ and 1.9㎓. It was found that the ratio of the length of positive $\tau\varepsilon$ materal to the length of negative $\tau\varepsilon$ material is constant at various resonance frequencies.

  • PDF

Spinal Lymphoma in a Cat (고양이에서 척수림프종의 발생례)

  • 권오경;홍성혁
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.279-284
    • /
    • 2000
  • A 3.5kg, 3-year-old castrated male Japanese domestic cat withpelvic limb ataxia and dysuria was referred to the Veterinary Medical Center of the Tokyo University. On the neurologic examination findings, both pelivic had a LMN paresis. The cat was FeLV positive and FIV negative. Radiographic findings did not identify the spinal lesions. In magnetic resonance images(MRI) of the lumbar spinal cord, the cat had the lesions in the lumbar(L) 1 and L3, characterized by hyperintensity on a transverse T2-weighted and T1-weighted images, and contrast enhancement was evident. The mass removed by dorsal laminectomy. Histopathological examination of the mass revealed spinal lymphoma. Three weeks after the surgery, the cat administered chemotherapy protocol for lymphoma by current protocol. Two weeks after chemotherapy, the cat had a metastasis to bone marrow and died.

  • PDF

MR Contrast Agents and Molecular Imaging (MR조영제와 분자영상)

  • Moon, Woo-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.2
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.

Breast Magnetic Resonance Imaging Indications in Current Practice

  • Taif, Sawsan Abdulkareem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.569-575
    • /
    • 2014
  • Although mammography is the primary imaging modality for the breast, it has its limitations especially with dense breast parenchyma. Breast magnetic resonance imaging (MRI) has evolved into an important adjunctive tool as it is currently the most sensitive technique for breast cancer detection. Despite this high sensitivity, overlap in the appearances of some benign and malignant breast lesions results in additional unnecessary intervention with negative results. These false positives, in addition to high cost and limited availability, necessitate establishing proper indications for breast MRI. The literature was here reviewed for recent clinical trials, meta-analyses and review papers which have studied this important subject. PubMed; the US national library of medicine, was utilized to review the literature in the last twenty years. Using the obtained information, current uses of breast MRI are discussed in this paper to determine the indications which are relevant to clinical practice.

Classification of Cognitive States from fMRI data using Fisher Discriminant Ratio and Regions of Interest

  • Do, Luu Ngoc;Yang, Hyung Jeong
    • International Journal of Contents
    • /
    • v.8 no.4
    • /
    • pp.56-63
    • /
    • 2012
  • In recent decades, analyzing the activities of human brain achieved some accomplishments by using the functional Magnetic Resonance Imaging (fMRI) technique. fMRI data provide a sequence of three-dimensional images related to human brain's activity which can be used to detect instantaneous cognitive states by applying machine learning methods. In this paper, we propose a new approach for distinguishing human's cognitive states such as "observing a picture" versus "reading a sentence" and "reading an affirmative sentence" versus "reading a negative sentence". Since fMRI data are high dimensional (about 100,000 features in each sample), extremely sparse and noisy, feature selection is a very important step for increasing classification accuracy and reducing processing time. We used the Fisher Discriminant Ratio to select the most powerful discriminative features from some Regions of Interest (ROIs). The experimental results showed that our approach achieved the best performance compared to other feature extraction methods with the average accuracy approximately 95.83% for the first study and 99.5% for the second study.