• Title/Summary/Keyword: Neer type II

Search Result 9, Processing Time 0.029 seconds

The Use of Hook Plate on the Management of Unstable Neer II Lateral End Fracture of The Clavicle (불안정한 Neer II형 원위쇄골 골절의 치료에서 Hook 금속판의 이용)

  • Ko, Sang-Hun;Cho, Sung-Do;Park, Moon-Soo;Ryu, SuGoo
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.131-137
    • /
    • 2003
  • Purpose: Unstable Neer type II lateral end fracture of clavicle may be required operation. The purpose of this study is the effectiveness of the use of Hook plate in the management of unstable Neer type II fractures. We preliminary reported the results of Unstable Neer type II lateral end fracture of clavicle using by Hook plate. Material and Methods: From May 1998 to May 2002, we operated 6 cases unstable Neer type II lateral end fracture of clavicle with Hook plate by one surgeon. We checked radiologic evaluation and disappearance of pain per 1 week, and evaluated improvement of range of motion per 2 week. And we followed up at each interval 3 months,6 months, 12 months and after that per 6months interval, at that each time we checked stress radiogram of shoulder and functional evaluation. The shoulder function was evaluated using Modified Shoulder Rating Scale (MSRC) for Distal Clavicle Fracture and UCLA score. Average follow up was on 37.2 (12∼57) months. Results: All 6 patients were regained satisfactory function. Average MSRC for distal clavicle fracture was 17.3 (15∼20) and average UCLA score was 33.2 (31∼35) at last follow up. Conclusion: There are many advantage of the use of Hook plate on management of unstable Neer II distal clavicle fracture in spite of several disadvantage. There have not yet been reported in our country. So we obtained good to excellent clinical result in surgical treatment of 6 cases on type II displaced lateral end fracture of the clavicle. But we think that more cases will be review and longer follow up will be needed in the future.

Mini-T Plate Fixation for Neer Type II Distal Clavicle Fracture (Neer 분류 제 2형 원위부 쇄골 골절의 mini-T형 금속판 고정)

  • Yum, Jae-Kwang;Lee, Sang-Lim;Ra, Ho-Jong
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose: To evaluate and report the clinical and radiological outcomes of open reduction and internal fixation with a mini-T plate for unstable distal clavicle fractures. Materials and Methods: From December 2004 to July 2007, fifteen patients who had a fracture of the distal clavicle (Neer type II fracture) were treated with an open reduction and internal fixation using a mini-T plate. They were followed up for a minimum of one year and the clinical and radiological results were analyzed. Results: The average time to fracture union was 3.1(3~4) months. There were no complications, such as deep infection or fixation loss. The mean ASES score was 97 points (85~100points) at the last follow up period, and 14 patients had a full range of motion of the shoulder. Conclusion: Open reduction and internal fixation with a mini-T plate for unstable distal clavicle fracture is a good surgical method with good clinical and radiological results.

Surgical Treatment of Unstable Distal Clavicle Fractures: Comparison of Transacromial Pin Fixation and Hook Plate Fixation (불안정 원위 쇄골 골절의 수술적 치료: 경견봉 강선 고정술과 갈고리형 금속판 고정술의 비교)

  • Kim, Young Sung;Lee, Ho Min;Jang, Han Gil
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The purpose of this study is to compare the clinical and radiological outcomes of two surgical treatments, transacromial pin fixation and hook plate fixation, for unstable distal clavicle fractures. Materials and Methods: Twenty four patients with Neer type II distal clavicle fractures who underwent surgery with transacromial pin fixation (Group I: 12 patients) and hook plate fixation (Group II: 12 patients) were included. Reduction and union were evaluated using plain radiographs. Functional evaluation was performed according to UCLA score and Constant-Murley score at last follow-up. Results: All 24 cases showed bone union. Complete union took an average of 10 weeks for group I and 11.7 weeks for group II. Average UCLA score was 33 (group I) and 32.8 (group II). Average Constant score was 88.5 (group I) and 88.8 (group II). No significant difference for each variable was observed between the two groups. Conclusion: For the surgical treatment of Neer type II distal clavicle fractures, transacromial pin fixation and hook plate fixation are both useful methods.

The Results of Rotator Cuff Disease Treated by Arthroscopic Subacromial Decompression (회전근개 질환에서 시행한 관절경적 견봉하 감압술의 결과)

  • Kim Jae-Hwa;Han Seung-Kwan;Cho Duck-Yun
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.110-114
    • /
    • 1999
  • We reviewed the results of arthroscopic surgery in patients with rotator cuff disease. Arthroscopic subacromial decompression(ASD) was performed on 22 patients with rotator cuff disease who had not responded to nonoperative measures. In the patients who had a complete tear of the rotator cuff(four of ten Neer's stage III patients), mini-open repair also was performed. Results were determined by questioning patients about their satisfaction with the outcome of surgery and by functional assessment of the shoulder with the parameters of pain, function, and range of motion according to the UCLA shoulder rating scale. The average follow-up was 21 months. The results were sixteen(72%) excellent, three(14%) good, two(9%) fair, and one(5%) poor. The following variables were analyzed to assess their influence on final outcome; duration of preoperative symptoms, Neer's stage(extent of damage to the cuff), type of acromion. Satisfactory results were achieved in thirteen of fourteen patients(93%) who had duration of preoperative symptoms below one year, and in four of six(67%) above 2 years. And satisfactory results were achieved in eleven of twelve patients(92%) who had Neer's stage II and in eight of ten(80%) stage III and achieved in six of seven patients(86%) who had Bigliani's acromion type I, in nine of eleven(82%) type II, and in four of four(100%) type III. There are multiple factors that may influence the recovery after ASD or the eventual outcome. However, although there is still a controversy about the pathogenesis of rotator cuff disease, We found that arthroscopic subacromial decompression and mini-open repair in patients with rotator cuff disease were well enough documented to be considered a standard treatment.

  • PDF

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

A Novel Fluoroscopic View for Positioning the AO Clavicle Hook Plate Decreases Its Associated in situ Complications

  • Hyun, Yoon-Suk;Kim, Gab-Lae;Choi, Sang-Min;Shin, Woo-Jin;Seo, Dong-Yeon
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • Background: The goal of this study was to evaluate whether a modified fluoroscopic technique for positioning a hook plate affected the clinical results of treating Neer type II distal clavicle fractures and Rockwood type V acromioclavicular (AC) joint separations with this device. Methods: The study was a retrospective consecutive case series with data analysis. Sixty-four patients with a Neer type II distal clavicle fracture or a Rockwood type V AC joint injury treated between March 2009 and June 2013 were divided into 2 groups: traditional fluoroscopic technique (traditional view, 31 patients) or modified fluoroscopic technique ('hook' view, 33 patients). A visual analogue scale (VAS) score, the modified University of California-Los Angeles (UCLA) shoulder scale score, and radiographic osteolysis were the main outcome measures. Results: The traditional group included a significantly larger number of patients with acromial osteolysis than the hook view group: 23 patients (74.2%) vs. 11 patients (33.3%), respectively (p=0.01). Before plate removal, the hook group reported less pain and higher UCLA shoulder scale scores than the traditional group: average VAS score, 1.55 vs. 2.26, respectively; average UCLA score, 30.88 vs. 27.06, respectively. However, there was no significant difference after plate removal. Conclusions: The hook view allows more accurate bending of the hook plate around the contour of the acromion, resulting in decreased osteolysis, decreased pain, and better function with the plate in situ.

Surgical Treatment for Type 11 Distal Clavicle Fracture using Mersilene tape and K-wire (Mersilene tape와 K-강선을 이용한 제 II형 원위부 쇄골 골절의 수술적 치료)

  • Byun, Jae-Yong;Kim, Bo-Hyun;Kang, Shin-Taek;Whang, Chan-Ha;Hong, Chang-Wha;Lee, Bum-Sung
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.2
    • /
    • pp.123-128
    • /
    • 2006
  • Purpose: Surgical reconstruction is usually indicated for type II distal clavicle fracture due to high rate of nonunion and delayed union. We report the clinical outcome of a surgical technique for type II distal clavicle fracture using Mersilen tape and K-wire. Materials and Methods: From 1999 through 2003, this technique has been used on 11 patients with type II distal clavicle fracture. The procedure consist of fracture reduction with a Mersilene tape, repair of torn coracoclavicular ligament, and K-wire fixation of the fracture fragment. All patients with at least 12 months of complete postoperative follow-up were included for functional and radiographic evaluation. We used simple X-ray and UCLA scoring system and constant scoring system for evaluation at last follow up in OPD. Results: Solid union of the fracture could be achieved at 11 weeks after operation in all patients. All patients could return to the same level of preinjury activity. Good and excellent results were obtained in all patients according to UCLA system. Conclusion: This technique was simple procedure and allowed for stable fixation with early mobilization and early return to work and sports.

  • PDF

3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures (3.5 mm T형 잠김 금속판을 이용한 원위 쇄골 골절의 치료 결과)

  • Lee, Churl-Woo;Kim, Hee-Chun;Roh, Jae-Young;Park, Young-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.