Breakdown Characteristic of Transformer Oil Depending on Tip Radius (침전극 곡률 반경에 따른 절연유의 절연파괴 특성)

  • Lee, J.S.;Jeong, S.H.;Lee, H.K.;Lim, K.J.;Kim, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1478-1480
    • /
    • 1997
  • We investigated the breakdown characteristic of mineral oil according to applied voltage and tip radius. In this experiment, electrode system was point-plane geometry. The tip radius of needle was 5, 10, 20 and $25{\mu}m$, respectively. Applied voltage was AC and DC. We measured breakdown voltage for each tip radius with increasing electrode gap, 2mm to 10mm. Under nonuniform electric field, breakdown strength was higher when needle was negative than when needle was positive. Because it is polarity effects due to space charge. And the more sharp tip radius, whether we applied AC or DC, the higher breakdown strength. As tip radius increase, breakdown strength decreases exponentially.

  • PDF

The Spread of Contrast Media in Celiac Plexus Block (복강신경총 차단시의 조영제 확산)

  • Lee, Jung-Koo;Chung, Jung-Kil;Lee, Sung-Moon
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.211-216
    • /
    • 1994
  • Celiac plexus block is performed to relieve intractable upper abdominal cancer pain. Generally, celiac plexus blocks have been performed under control of X-ray fluoroscopy to determine the position of the needle tip and the spread of contrast media. During the period from March 1992 to February 1994, we have performed 21 cases of neurolytic celiac plexus block to alleviate pain of intra-abdominal malignancy. We retrospectively evaluated the location of the needle tip and the spread of contrast media. P-A views of simple abdomen demonstrated the locations of the needle tip: 66.7% of the left needle tips were in upper 3/1 of L1 (6 cases) and $T_{12}-L_1$ interspace (8 cases), 50% of the right needle tips were in upper 1/3 of $L_1$, (6 cases) and $T_{12}-L_1$ interspace (4 cases). Contrast media from the right needle spread upward to middle 1/3 of $T_{10}$ (5 cases) and middle 1/3 of $T_{11}$ (5 cases), downward to middle 1/3 of $L_1$ (6 cases) and lower 1/3 of $L_1$ (3 cases). Contrast media from the left needle were spread upward to middle 1/3 of $T_{10}$ (5 cases) and evenly to other spaces, downward to middle 1/3 of $L_1$, (4 cases) and $L_1-L_2$ interspace (6 cases). We analyze the spread of contrast media according to distance from needle tip by authors score system. Contrast media of right needle spread upward 6.1 and downward 3.4, that of left needle spread upward 6.5 and downward 3.7.

  • PDF

Investigation of Micromorphological Characteristics of Acupuncture Needle Tip Using SEM-EDX (SEM-EDX를 이용한 침 끝의 미세 부착물의 조성에 대한 관찰)

  • Jang, In-Soo;Son, Dong-Hyuk;Song, Ho-Seop;Lee, In-Hwan;Park, Jong-Bae
    • Journal of Acupuncture Research
    • /
    • v.22 no.6
    • /
    • pp.135-140
    • /
    • 2005
  • Objectives : There have been several studies about the quality of acupuncture needle tip recently. We have investigated the condition of the tip of the acupuncture needles in the last studies. In the former studies, we discovered the metallic scuff, lumps and irregularities of the acupuncture needle tips under the microscope. But, no information was available on those foreign materials' identity. Methods : We have selected 200 needles of 1000 pieces from several companies by randomized methods. And we observed the tip of the 6 needles selected finally at ${\times}1000\;or\;{\times}3000$ magnification and analyzed the components of the metallic scuff, lumps and irregularities of the needle tips with a SEM-EDX analyser. Results : We found that the identity of the metallic scuff, lumps and irregularities of the needle tips were metallic materials and silicon. For example, A point was composed of Fe(69.78%), Cr(17.71%), Ni(8.11%), Zn(2.04%), Si(1.23%), Mn(1.12%), and B point was composed of Si(66.40%), Fe(26.76%), Cr(6.84%). Conclusion : The results of this study confirm that there is a real possibility of the remaining of metallic materials and silicon in body of patient, after acupuncture treatment. Therefore, it is necessary to intensify our efforts to make needles of good quality and to concentrate on manufacturing process of acupuncture needles completely to be free from danger in acupuncture treatment.

  • PDF

Evaluation of the Influence of Alignment Error in the Sharpness Test of a Micro-Needle (세침의 예리도 시험에서의 정렬 오차 영향 평가)

  • Lee J. K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.05a
    • /
    • pp.250-253
    • /
    • 2004
  • Sharpness of the tip of micro needle is very Important quality that should be controlled in the manufacturing processes. Acupuncture needle is one of the most widely used micro-needle. And the tip sharpness of acupuncture needle Is usually checked by the magnitude of resisting force obtained through sharpness test. In this study, some sharpness tests of acupuncture needle were done and the relationship between the misalignment of specimen and the magnitude of resisting force. The diameter of the needle used in the test was $250\;{\mu}m$ and the length of it was 40 mm.

  • PDF

Dependence of needle tip Curvature of the Inception Stress and Propagation of electrical tree (침전극의 곡율반경에 따른 트리개시전계 및 트리진전 특성)

  • 박영국;김완수;이홍규;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.59-62
    • /
    • 1999
  • Inception and propagation of electrical tree and properties of Partial discharge(PD) pulses accompanying with tree as a function of needle tip radius in low density polyethylene were discussed. To study on these characteristics in different tip radius, we used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscope with computer and investigated the characteristics of the phase resolved PD pulses accompanying with propagation of electrical tree. The PD quantities detected and analysed were PD magnitude, mean phase angle, average discharge, and the statistical characteristics of the PD pulses. As the tip radius ${\gamma}$ increases, tree inception stress E$\sub$i/ converges to constance value. This result suggests that tree inception stress E$\sub$i/ increases due to stress relaxation when the tip radius is small. Branch-type electrical tree was formed When E$\sub$i/ is 640-750[kV/mm]. bush-type electrical tree when E$\sub$i/ is 370∼400[kV/mm], branch-like electrical tree when E$\sub$i/ is 370-400[kV/mm].

  • PDF

Development of Automatic Visual Inspection System for Micro Needle (미세 탐침의 비전 자동 검사 시스템 개발)

  • Kang, Su-Min;Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.16-25
    • /
    • 2008
  • The micro needle means the ultrafine probe of 'Probe Card'. The size of micro needle is so minute that it is difficult to minute that it is difficult to inspect it with eyes. On the other hand it is very critical if there is a defect in micro needle of probe card. In this study, we developed an automatic visual inspection system for finding defect status in probe angle, tip length and diameter. Through the experimental results, we could find that our proposed method is better than human-eyes inspection method in accuracy and inspection speed, and also in robustness to lighting circumstances.

Alternative Method of Retrocrural Approach during Celiac Plexus Block Using a Bent Tip Needle

  • An, Ji Won;Choi, Eun Kyeong;Park, Chol Hee;Choi, Jong Bum;Ko, Dong-Kyun;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • v.28 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Background: This study sought to determine safe ranges of oblique angle, skin entry point and needle length by reviewing computed tomography (CT) scans and to evaluate the usefulness of a bent tip needle during celiac plexus block (CPB). Methods: CT scans of 60 CPB patients were reviewed. Image of the uppermost margin of L2 vertebral body was used to measure the minimal and maximal oblique angles and the distances from the midline to skin puncture point. The imaginary needle trajectory distance was calculated by three-dimensional measurement. When the procedure was performed by using a $10^{\circ}$ bent tip needle under a $20^{\circ}$ oblique X-ray fluoroscopic view, the distance (GF/G'F) from the midline to the actual puncture site was measured. Results: The imaginary safe oblique angle range was $26.4-34.2^{\circ}$ and $27.7-36.0^{\circ}$ on the right and left, respectively. The distance from the midline to skin puncture point was 6.1-7.6 cm on the right and 6.3-7.6 cm on the left. The needle trajectory distance at minimal angle was 9.6-11.6 cm on the right and 9.5-11.5 cm on the left. The distance of GF/G'F was 5.1-6.5 cm and 5.0-6.4 cm on the right and left, respectively. All imaginary parameters were correlated with BMI except for GF/G'F. All complications were mild and transient. Conclusions: We identified safe values of angles and distances using a straight needle. Furthermore, using a bent tip needle under a $20^{\circ}$ oblique fluoroscopic view, we could safely perform CPB with smaller parameter values.

Illustrations of the Nine Types of Needles based on Huangdi's Internal Classic Ling-shu

  • Kim, Hyo Jin;Lee, Kwang Ho;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • v.36 no.1
    • /
    • pp.38-44
    • /
    • 2019
  • Background: The phrase "Nine Needles" refers to the 9 types of acupuncture needles describing their shapes, sizes, and uses in Huangdi's Internal Classic Ling-shu. The aim of this study was to present 3D illustrations of the "Nine Types of Needles" based on Huangdi's Internal classic Ling-shu, taking into consideration the conformation and application of the Nine Needles. Methods: Sketches of the "Nine Needles" were based on references to those needles cited in Huangdi's Internal Classic Ling-shu, the Great Compendium of Acupuncture and Moxibustion, and the Golden Mirror of Medicine. The computer programs Creo 3.0, Keyshot 5, Adobe Photoshop CS5, and Adobe Illustrator CS5 were used for 3D modelling and visualization. Results: Based on a review of Huangdi's Internal Classic Ling-shu, illustrations of the Spade needle, Round-Pointed needle, Pressure needle, Sharp-Edged needle, Sword-Shaped needle, Round-Sharp needle, Fine needle, Long needle, and Large needle, 3D models were created. The Spade needle had a sharp, large head, the Round-Pointed needle had an egg-shaped tip, and the Pressure needle had a blunt head like a grain of millet. The Sharp-Edged needle had a sharp blade with a triangular edge for bloodletting. The Sword-Shaped needle resembled a sword. The Round-Sharp needle resembled a horse's tail. The Fine needle and the Long needle had sharp points and thin bodies. The Large needle had a cylindrical shaft and rounded tip. Conclusion: This study demonstrated that 3D illustrations could be generated for the Nine Needles according to the descriptions and figures provided in the ancient literature.

A Study on the Semi-conductor Package Process Epoxy Moulding Compound Gun (반도체 Package 공정용 EMC Gun에 관한 연구)

  • Cho, Myung-Hyun;Kim, Gyu-Sung
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.83-92
    • /
    • 2006
  • EMC(epoxy moulding compound) when operate with residual quantity processing after fixed quantity moulding inverse close way of designing by mechanical action inhalation so that may occur, solved of needle tip residual quantity and cause of thread extend phenomenon. In this paper, design to connect directly gun, washer tank and measuring beforehand amount that washing is easy and want minuteness fixed quantity that essential equipment in semi-conductor packaging process because develop EMC so that can molding with high speed consider.

Electrohydrodynamic Pumping Characteristics of the Needle-Centered Nozzle Electrode (침심 노즐전극의 전기유체역학적 펌핑 특성)

  • Jung, Hoi-Won;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1812-1817
    • /
    • 2008
  • A cooling system for microelectronics is becoming more important as its surface heat density is projected to reach that of the sun surface. The existing technologies using natural and forced convection are limited to solve the problems. Recently, an electrohydrodynamic driven flow is studied as one of the means to cope with this problems. A new method, utilizing a needle-centered nozzle electrode, has been proposed and investigated. The I-V characteristics of the nozzle electrode for deionized water and silicone oil were significantly different from that of without liquid, which might be due to the liquid drop covered on the nozzle tip by the EHD force acting near the needle tip. Results showed that the liquid pumping rate and flow efficiency of the nozzle electrode were very high, especially for the silicone oil. Theoretical analysis also showed the effectiveness of the needle electrode centered in the ceramic nozzle, which, however, can be a means as a liquid pump.