• 제목/요약/키워드: Near infrared spectra

검색결과 361건 처리시간 0.022초

THE CENTRAL REGION OF THE BARRED SPIRAL GALAXY NGC 1097 PROBED BY AKARI NEAR-INFRARED SPECTROSCOPY

  • Kondo, T.;Kaneda, H.;Oyabu, S.;Ishihara, D.;Mori, T.;Yamagishi, M.;Onaka, T.;Sakon, I.;Suzuki, T.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.257-258
    • /
    • 2012
  • With AKARI, we carried out near-infrared spectroscopy of the nearby barred spiral galaxy, NGC 1097, categorized as Seyfert 1 with a circumnuclear starburst ring. Our observations mapped the galactic center region. As a result, we obtain the spatial distributions of the polycyclic aromatic hydrocarbon $3.3{\mu}m$ and the aliphatic hydrocarbon $3.4-3.6{\mu}m$ emission. The former is detected from all the observed regions and the latter is enhanced near the bar connecting the ring with the nucleus. In addition, we detect absorption features due to $H_2O$ ice and CO/SiO at the ring and the galactic center, while we detect the hydrogen recombination line $Br{\alpha}$ only from the ring. Hence the observed spectra change dramatically within the central 1 kpc region.

사과 경도의 비파괴측정을 위한 검량식 개발 및 정확도 향상을 위한 연구 (Development of Calibration Model for Firmness Evaluation of Apple Fruit using Near-infrared Reflectance Spectroscopy)

  • 손미령;조래광
    • 한국식품저장유통학회지
    • /
    • 제6권1호
    • /
    • pp.29-36
    • /
    • 1999
  • Using Fuji apple fruits cultivated in Kyungpook prefecture, the calibration model for firmness evaluation of fruits by near infrared(NIR) reflectance spectroscopy was developed, and the various influence factors such as instrument variety, measuring method, sample group, apple peel and selection of firmness point were investigated. Spectra of sample were recorded in wavelength range of 1100∼2500nm using NIR spectrometer (InfraAlyzer 500), and data were analyzed by stepwise multiple linear regression of IDAS program. The accuracy of calibration model was the highest when using sample group with wide range, and the firmness mean values obtained in graph by texture analyser(TA) were used as standard data. Chemometrics models were developed using a calibration set of 324 samples and an independent validation set of 216 samples to evaluate the predictive ability of the models. The correlation coefficients and standard error of prediction were 0.84 and 0.094kg, respectively. Using developed calibration model, it was possible to monitor the firmness change of fruits during storage frequently. Time, which was reached to firmness high value in graph by TA, is possible to use as new parameter for freshness of fruit surface during storage.

  • PDF

VARIOUS NIR SAMPLE PRESENTATIONS FOR AGRICULTURAL PRODUCTS SUCH AS INTACT FRUITS, SINGLE GRAINS, VEGETABLE JUICE, MILK AND THE OTHERS

  • Kawano, Sumio
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1021-1021
    • /
    • 2001
  • Sample presentation, which means how to set samples to an NIR instrument, is very important in Near Infrared (NIR) Spectroscopy. When sample presentation is not suitable for the samples that you use, very good spectra can not be obtained even if you use a sophisticated NIR instrument. In my presentation, various NIR sample presentations for agricultural products such as intact fruits, single grains, vegetable juice and the others will be explained. In case of peaches with thin peel, the fiber optics of Interactance can be used. However, the fiber optics are not suitable for oranges with relatively thick peel. In this case, transmittance method is useful. As for a small sample such as single grains, a specially designed cell is needed. The cell in transmittance mode has been developed and then applied to single kernels of rice and soybean. In this case we also used the fiber optics. As regards liquid type of sample, a cuvette cell made of quartz in transmittance mode is popular. However, it is time-consuming to wash and dry it. In order to compensate this disadvantage the sample presentation using normal test tubes as sample cells have been developed and applied to milk, rumen juice and urine of a milking cow. An individual test tube can be used for each sample if you use the calibration equation with sample cell compensation. The test tube cell has also been applied to spinach juice for determination of undesirable constituents. It is concluded that sample presentation is most important for NIR Spectroscopy.

  • PDF

OPTIMISING CALIBRATION TRANSFER TO MEASURE DEGRADABILITY PARAMETERS OF HAYS AND DEHYDRATED FORAGES

  • Andueza, Donato;Munoz, Fernando;Martinez, Adela;De La Roza, Begona
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1268-1268
    • /
    • 2001
  • The availability of in vivo and in sacco degradability values are limited because those methods require work with fistulated animals and are rather complicated, labour intensive and expensive. That is to say, the dynamics and logistics of the methodology result in considerable work, due to limitations on the amount of samples, number of bags that can be placed in an animal and different time intervals to perform kinetic studies. Therefore, a simpler method is necessary to estimate the degradation characteristics of the feed. In this way, near infrared reflectance spectroscopy has been used to predict degradation characteristics of forages. In other hand, the possibility of achieving successful transfer of spectra and equations between instruments is closely related. The objective of this study was to confirm the potential of NIR to optimize work conditions to avoid duplicated efforts in collaborative trials on animal feeds evaluation between research institutions. For this purpose, one set with forty hays and dehydrated forages samples from SERIDA and ten samples with the same characteristics from SIA, were be used to create a spectral database. A calibration was developed using samples from degradation essays made in SERIDA to predict dry matter and crude protein degradability. With the addition of five samples from SIA in original calibration set, the effect of different origin and location was compensated.

  • PDF

Determination of Water Content in Ethanol by Miniaturized Near-Infrared (NIR) System

  • Cho, Soo-Hwa;Chung, Hoe-Il;Woo, Young-Ah;Kim, Hyo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권1호
    • /
    • pp.115-118
    • /
    • 2005
  • The miniaturized NIR (Near-infrared) spectrometer has been utilized for the determination of water content (1-19% range) in ethanol that is the most popular organic solvent in pharmaceutical industries. It has many potential capabilities that can replace the conventional analyzers especially for the on-line measurement since it is compact, versatile and cost-effective. By using two dimensional (2D) correlation spectroscopy, it was preliminarily investigated to find any unforeseen spectral distortion among the spectra collected from the miniaturized spectrometer. The 2D study revealed that the spectral variation clearly followed the variation of water concentration without any spectral distortion or abnormality. PLS (Partial Least Squares) was employed to build the calibration model and the resulting prediction performance was acceptable and stable over several days. Even though the miniaturized NIR system was evaluated to fairly simple chemical matrix, the overall study demonstrates the sufficient feasibility for diverse practical and industrial applications.

Development of Models for the Prediction of Domestic Red Pepper (Capsicum annuum L.) Powder Capsaicinoid Content using Visible and Near-infrared Spectroscopy

  • Lim, Jongguk;Mo, Changyeun;Kim, Giyoung;Kim, Moon S.;Lee, Hoyoung
    • Journal of Biosystems Engineering
    • /
    • 제40권1호
    • /
    • pp.47-60
    • /
    • 2015
  • Purpose: The purpose of this study was to non-destructively and quickly predict the capsaicinoid content of domestic red pepper powders from various areas of Korea using a pungency measurement system in combination with visible and near-infrared (VNIR) spectroscopic techniques. Methods: The reflectance spectra of 149 red pepper powder samples from 14 areas of Korea were obtained in the wavelength range of 450-950 nm and partial least squares regression (PLSR) models for the prediction of capsaicinoid content were developed using area models. Results: The determination coefficient of validation (RV2), standard error of prediction (SEP), and residual prediction deviation (RPD) for the capsaicinoid content prediction model for the Namyoungyang area were 0.985, ${\pm}2.17mg/100g$, and 7.94, respectively. Conclusions: These results show the possibility of VNIR spectroscopy combined with PLSR models in the non-destructive and facile prediction of capsaicinoid content of red pepper powders from Korea.

1100∼2200 nm 파장 영역의 휴대용 근적외선 분광분석기를 이용한 사람피부의 수분측정 (Determination of Human Skin Moisture in the Near-Infrared Region from 1100 to 2200 nm by Portable NIR System)

  • 안지원;서은정;우영아;김효진
    • 약학회지
    • /
    • 제47권3호
    • /
    • pp.148-153
    • /
    • 2003
  • Skin moisture is an important factor in skin health. Measurement of moisture content can provide diagnostic information on the condition of skin. In this study, a portable near-infrared (NIR) system was newly integrated with a photo diode array detector that has no moving parts, and this system has been successfully applied for the evaluation of human skin moisture. Diffuse reflectance spectra were collected and transformed to absorbance using 1 nm step size over the wavelength range of 1100 nm to 2200 nm. Partial least squares regression (PLSR) was applied to develop a calibration model. For practical use for the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo using the portable NIR system on the basis of the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. The calibration with the use of PLS model predicted human moisture with a standard error of prediction (SEP) of 3.5 at 1120∼1730 nm range. This study showed the possibility of skin moisture measurement using portable NIR system.

근적외선 분광분석법을 이용한 생약의 원산지 판별 (Discrimination of Herbal Medicine According to Geographical Origin (Korea, China) Using Near Infrared Reflectance Spectroscopy)

  • 우영아;조창희;김효진;조정환;조경규;정승성;김수정;김중환
    • 약학회지
    • /
    • 제42권4호
    • /
    • pp.359-363
    • /
    • 1998
  • Near infrared reflectance spectroscopy (NIRS) was applied for discrimination according to geographical origin (Korea, China) of herb drugs. Herbal medicine has an important role in clinical therapy in Asian countries such as Korea and China. The objective of this study is to provide a convenient and accurate method to determinate geographical origin (Korea, China) of herbal medicine for quality control whose quality is generally different according to geographical origin. A rapid, nondestructive and accurate discrimination was achieved by NIRS. Second derivative spectra of herb drugs were subjected to discriminant analysis. Herbal medicine drugs such as Cassia Semen, Ganoderma and Smilacis Rhizoma was discriminated accurately according to geographical origin using PLS regression method.

  • PDF

근적외 분광분석법을 이용한 나프록센 정제의 정량분석 (Quantification of Naproxen in Pharmaceutical Formulation using Near-Infrared Spectrometry)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제49권1호
    • /
    • pp.1-5
    • /
    • 2005
  • Near-infrared (NIR) spectroscopy has been widely applied in various field, since it is nondestructive and no sample preparation is required. In this paper, NIR spectroscopy was used for the determination of naproxen in a commercial pharmaceutical preparation. NIR spectroscopy was used to determine the content of naproxen in intact naproxen tablets containing 250 mg ($65.8\%$ nominal concentration) by collecting NIR spectra in the range of $1100{\sim}1750nm$. The laboratory-made samples had $46.1{\sim}85.5\%$ nominal naproxen concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR). Model validation was performed by randomly splitting the data set into calibration and validation data set (63 samples as a calibration data set and 42 samples as a validation data set). The developed NIR calibration gave results comparable to the known values of tablets in a laboratorial manufacturing process with standard error of calibration (SEC) and standard error of prediction (SEP) of $1.06\%\;and\;1.04\%$, respectively. The NIR method showed good accuracy and repeatability. NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Noncontact strain sensing in cement-based material using laser-induced fluorescence from nanotube-based skin

  • Meng, Wei;Bachilo, Sergei M.;Parol, Jafarali;Weisman, R. Bruce;Nagarajaiah, Satish
    • Structural Monitoring and Maintenance
    • /
    • 제9권3호
    • /
    • pp.259-270
    • /
    • 2022
  • This study explores the use of the recently developed "strain-sensing smart skin" (S4) method for noncontact strain measurements on cement-based samples. S4 sensors are single-wall carbon nanotubes dilutely embedded in thin polymer films. Strains transmitted to the nanotubes cause systematic shifts in their near-infrared fluorescence spectra, which are analyzed to deduce local strain values. It is found that with cement-based materials, this method is hampered by spectral interference from structured near-infrared cement luminescence. However, application of an opaque blocking layer between the specimen surface and the nanotube sensing film enables interference-free strain measurements. Tests were performed on cement, mortar, and concrete specimens with such modified S4 coatings. When specimens were subjected to uniaxial compressive stress, the spectral peak separations varied linearly and predictably with induced strain. These results demonstrate that S4 is a promising emerging technology for measuring strains down to ca. 30 𝜇𝜀 in concrete structures.