• Title/Summary/Keyword: Nd:YAG

Search Result 1,085, Processing Time 0.026 seconds

Experimental Investigation on Flow Characteristics of Chicken Blood in a Micro Tube Using a Micro-PIV Technique (마이크로 PIV를 이용한 미세튜브 내부 조류 혈액유동에 관한 실험적 연구)

  • Yeo, Chang-Sub;Ji, Ho-Seong;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1027-1034
    • /
    • 2006
  • In order to investigate flow characteristics of chicken blood in a micro tube of 100$\mu$m in diameter, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, 2-head Nd:YAG laser, 12 bit cooled CCD camera and a delay generator. Chicken blood with 40% hematocrit was supplied into a micro tube using a syringe pump. The blood flow shows clearly the cell free layer near the tube wall and its thickness is increased with increasing the flow speed. The hemorheological characteristics of chicken blood, including shear rate and shear stress were estimated from the PIV velocity field data obtained. Since the aggregation index of chicken blood is less than 50% of human blood, non-Newtonian flow characteristics of chicken blood are smaller than those of human blood. As the flow rate increases, the degree of flatness in the velocity profile at the center region is decreased and the parabola-shaped shear stress distribution becomes to have a linear profile. Under the same flow rate, chicken blood shows higher shear stress, compared with human blood.

Measurements on a Ship's Sloshing Flows by PIV (PIV에 의한 선박 슬로싱 유동 측정해석)

  • Doh, Deog-Hee;Cho, Yong-Beom;Pyeon, Yong-Beom;Baek, Tae-Sil;Kwon, Soon-Hong;Lee, Jeong-Han;Hwang, Yoon-Sik;Ryu, Min-Cheol
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.119-122
    • /
    • 2007
  • The sloshing flows in the cargo tank model of a ship are measured by PIV and are analyzed with the results. The measurement system is consisted of a Nd-Yag laser(120mJ, 15Hz). two cameras($1k\;{\times}\;1k$) and a host computer. Four experimental cases were tested for the tank model. in which swaying motions are made by 6 DOF-motion platform. The amplitudes of swaying are 9.76mm and 29.29mm, and the frequencies are 0.633Hz and 0.828Hz. The measurement regions are the vertical plane 50mm away from the front wall of the tank where a pump tower is installed. It was verified that the flow patterns of the sloshing are similar each other when the swaying amplitudes are similar.

  • PDF

A Study on UV Laser Ablation for Micromachining of PCB Type Substrate (다층 PCB 기판의 미세 가공을 위한 UV레이저 어블레이션에 관한 연구)

  • 장원석;김재구;윤경구;신보성;최두선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.887-890
    • /
    • 1997
  • Recently micromachining using DPSSL(Diode Pumped Solid State Laser) with 3rd harmonic wavelength is actively studied in laser machining area. Micromachining using DPSSL have outstanding advantages as UV source comparing with excimer laser in various aspect such a maintenance cost, maskless machining, high repetition rate and so on. In this study micro-drilling of PCB type substrate which consists of Cu-PI-Cu layer was performed using DPSS Nd:YAG laser(355nm, wavelength) in vector scanning method. Experimental and numerical method(Matlab simulation, FEM) are used to optimize process parameter and control machining depth. The man mechanism of this process is laser ablation. It is known that there is large gap between energy threshold of copper and that of PI. Matlab simulation considering energy threshold of material is performed to effect of duplication of pulse and FEM thermal analysis is used to predict the ablation depth of copper. This study could be widely used in various laser micromachining including via hole microdrilling of PCB, and micromachining of semiconductor components, medical parts and printer nozzle and so on.

  • PDF

A Preliminary Study on Developing a Photoacoustic Imaging System for Inflammatory Arthritis Diagnosis (관절염 진단용 광음향 이미징 시스템 개발을 위한 선행 연구)

  • Youn, Jong-In;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.4
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The goal of this study was to investigate the feasibility for the early diagnosis of inflammatory arthritis by the reconstruction of three-dimensional photoacoustic imaging with a tissue phantom. Methods: Q-switched Nd:YAG laser (l = 532 nm) was applied to a tissue phantom to generate photoacoustic waves, and the acquired photoacoustic signals at different positions around the sample were used to recombine the distribution of the optical absorption and the images were subsequently generated through a reconstruction algorithm. Results: From the acquired photoacoustic signals, the surface andinner core of the phantom was clearly distinguished. Furthermore, the back-projection algorithm was able to reconstruct two-dimensional and three-dimensional photoacoustic images that contained the optical absorption property information of the tissue phantom. Conclusion: The results indicate that the photoacoustic imaging technique has many advantages such as high optical contrast and high acoustic resolution. The acquired images can be used for the early diagnosis of inflammatory arthritis by the structural information obtained from the region of interest.

Effects of an Auto-tracking of the Focal Distance on the Quality of the Cut Part in the Laser Cutting of a Low Carbon Sheet (저탄소 강판의 레이저 절단에서 자동 초점거리 추적이 절단 품질에 미치는 영향)

  • Ahn, Dong-Gyu;Byun, Kyung-Won;Yoo, Young-Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.4
    • /
    • pp.101-107
    • /
    • 2007
  • The objective of this research work is to investigate into effects of an auto tracking of the focal distance on the quality of the cut part in the cutting of a low carbon sheet using a high-power CW Nd:YAG laser. An auto-tracking system with a capacitance based distance control loop has been employed to perform a real control of the focal distance. In order to examine the influence of the auto-tracking of a focal distance on the optimum focal distance, the kerfwidth, surface roughness and the formation of the cut section, several linear cutting tests have been carried out using the auto-tracking system. The results of experiments have been shown that the optimum focal distance is 0.9mm. In addition, it has been shown that the variation of kerfwidth and the surface roughness of the cut part with control of the focal distance are reduced 40-80% and 30-55% in comparison with those of the cut part without tracking of the focal distance. From the results of the experiments, it has been found that the real time tracking of the focal distance can improve the part quality.

Spray Characteristics of the Pressure Swirl Injector for the APU Gas Turbine Engine (APU 가스터빈엔진 압력식 스월인젝터의 분무특성)

  • Choi, Chea-Hong;Choi, Seong-Man;Lim, Byeong-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.359-364
    • /
    • 2007
  • Spray characteristics of the APU gas turbine engine were investigated. In order to understand blow out phenomena of the APU engine, we performed fuel spray test. In the test, four operating conditions such as sea level idle, sea level max power, 20,000 feet idle, 20,000 feet max power were used as spray experimental conditions. PDPA(phase Doppler Particle Analyzer) was used for measuring the particle diameter and velocity. Also spray visualization was performed by using ND-YAG sheet laser beam. From the test result, in the case of 20,000 feet idle condition, SMD is about 100 ${\mu}m$ and maximum particle velocity is about 10 m/s. For the flame stability, spray quality should be improved at 20,000 feet idle condition.

  • PDF

Rigid Bronchoscopic Treatment for an Adult Case of Multiple Squamous Papillomatosis in the Trachea (성인에서 발생한 다발성 기관 유두종증에 대한 경직성 기관지경을 이용한 치험 1 예)

  • Jung, Bock-Hyun;Lim, Jae-Min;Kim, Mi-Hye
    • Korean Journal of Bronchoesophagology
    • /
    • v.15 no.2
    • /
    • pp.81-86
    • /
    • 2009
  • A 57 year old human immune virus(HIV)-positive male presented with a progressive dyspnea for 6 months. Chest CT showed multiple polypoid masses arising from upper tracheal wall. Bronchoscopic examination revealed that multiple large cauliflower-like polypoid tumors was obstructing tracheal lumen. They were diagnosed as multiple squamous papillomas and were removed by Nd:YAG laser photocoagulation and rigid bronchoscopic treatment. The tumors were histologically diagnosed as squamous papilloma infected with human papilloma virus(HPV) type 6 and 11 in in-situ hybridization. Rigid bronchoscopy might be safer and more efficient than flexible bronchoscopy for the treatment of multiple tracheal papillomatosis obstructing tracheal lumen because of easy establishment of airway patency and direct use of rigid bronchoscope itself for tumor resection.

  • PDF

Numerical analysis of resonator stability and beam quality in a thermal-birefringence compensated symmetric resonator consisting of two laser rods with rod-end curvatures (두개의 렌즈형 레이저 막대들로 구성된 대칭형 공진기의 안정도 및 빔질의 수치적 분석)

  • Kim, Hyun-Su
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.575-582
    • /
    • 2004
  • We analyse the beam characteristics of the thermal-birefringence compensated symmetric resonator which consists of two laser rods with rod-end curvatures. The numerical results show that the stability and the beam quality can be improved in high power operation region when the rod-ends are made in the form of a negative lens. The thermal birefringence of the symmetric two-rods resonator is shown to be well compensated when the two rods closely contact each other.

The Laser Peening Effect for Improving the Surface Properties of Metals (금속표면 특성향상을 위한 laser peening 효과)

  • Chung, Chin-Man;Baik, Sung-Hoon;Kim, Joung-Soo;Lee, Sang-Bae
    • Laser Solutions
    • /
    • v.11 no.3
    • /
    • pp.5-9
    • /
    • 2008
  • The effect of a laser peening on the surface residual stress of SUS 304 was investigated using a second harmonic Nd:YAG laser beam. The energy density and the diameter of the laser beam were $400mJ/mm^2$ and about 1mm, respectively. According to the test results, the effect of a laser peening for improving the surface residual stress was not big enough to induce a high compressive stress on the SUS 304 surface. This is thought to be attributed to the small radius of the laser beam used in this study, even though its energy density is big enough. From this study, it can be concluded that to induce a recognizably high compressive stress on a metal surface, the energy density as well as the size (diameter) of the laser beam should be large enough to generate surface plasma with a high energy to have a big impact to a metal surface.

  • PDF

Measurements of the Cylinder Wake with a Hybrid-Fitness Function based 3D-PTV (적합함수 기반의 3D-PTV에 의한 원주후류 측정 해석)

  • Doh, Deog-Hee;Jo, Hyo-Jae;Baek, Tae-Sil
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.2
    • /
    • pp.3-8
    • /
    • 2008
  • A new 3D-PTV algorithm(a Volume PTV) based upon a hybrid fitness function has been constructed. A coherency fitness function is introduced using the information of space and time to sort out the correct particle pairs between the two camera images. The measurement system consists of two-high-definition-cameras($1k{\times}1k$), a Nd-Yag laser and a host computer. The developed algorithm has been employed to investigate the flow features of the cylinder wake. The Reynolds numbers with the cylinder diameter(d=10 mm) are 360, 540, 720, 900, 1080 and 1260. Two-dimensional displacements of the particles of each camera's image and neighbouring constraints were introduced to reduce the calculation loads. More than 10,000 instantaneous 3D vectors have been obtained by the constructed algorithm. The constructed algorithm could recover more than $80{\sim}90%$ of the particle numbers in the image condition.