• Title/Summary/Keyword: Nd:YAG

Search Result 1,085, Processing Time 0.021 seconds

Analysis of surface defect in RE : YAG (RE = Nd3+, Er3+, Yb3+) single crystal using chemical polishing and etching (화학적 polishing 및 etching을 통한 RE : YAG (RE = Nd3+, Er3+, Yb3+) 단결정의 표면 결함 분석)

  • Shim, Jang Bo;Kang, Jin Ki;Lee, Young Kuk
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.4
    • /
    • pp.131-134
    • /
    • 2016
  • The conditions for chemical polishing and etching technique were investigated to reveal surface defects in RE : YAG ($RE=Nd^{3+},\;Er^{3+},\;Yb^{3+}$) single crystals grown by Czochralski method. The optimal condition for chemical polishing was in 85 % $H_3PO_4$ solution at $330^{\circ}C$ for 30 minutes with a specimen fixed in the vertical direction. In addition, the optimal condition for chemical etching was in 85 % $H_3PO_4$ solution at $260^{\circ}C$ for 1 hour, and $70{\sim}80{\mu}m$ sized triangular etch pits were observed on (111) face. As a result of defect density analysis, $1.9{\times}10^3/cm^2$ for Nd(1 %) : YAG, $4.3{\times}10^2/cm^2$ for Er(7.3 %) : YAG, and $5.1{\times}10^2/cm^2$ for Yb(15 %) : YAG were measured.

The Output Characteristics of Low Repetition·High Power Nd:YAG Laser Using LLC Resonant Converter (LLC 공진형 컨버터를 활용한 저 반복·고출력 Nd:YAG 레이저의 출력특성)

  • Lee, Hee-Chang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.286-291
    • /
    • 2015
  • LLC resonant converter is used to control laser output power in Nd:YAG laser. Zero voltage switching (ZVS) is implemented to minimize the switching loss which is adopting the LLC resonant converter. In the spot welding processing of metal thin films, the processing quality is decided by the laser beam output energy of single pulse. We decide to the 50 [J] as the single pulse laser beam energy. Laser output power is investigated and experimented by changing the output current. That current is controled by the charging voltage of capacitor. From those results, we obtained the maximum laser output of 58.2 [J] and the conversion efficiency of 2.52% at the discharge voltage of 620V and the discharge current of 861 [A] and the pulse repetition rate of 1 [Hz] at the charging capacitor of 12,000 [${\mu}F$].

Sterilization Effect by the Nd:YAG Laser pulse (Nd:YAG 레이저 펄스에 따른 멸균효과)

  • Jeong, Kyeonghwan;Jung, Dongkyung;Park, Jeongkyu;Choi, Hyeonwoo;Seo, Jeongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.695-703
    • /
    • 2020
  • The use of medical devices is increasing due to the development of medical technology. Among medical devices, it is often used in the human body for graft and treatment. Therefore, in medical institutions, various sterilization methods according to the type and material of medical devices are applied to prevent infection. Hydrophosphite (HA) materials are the most popular in bone grafts. We would like to present a sterilization method using Q-switch Nd:YAG laser with high output energy among non-ionizing radiation suitable for small medical devices. In this study, sterilization power was most ideally shown at UV wavelengths of 1.5 W, 266 nm, and 10 pulses. Different wavelength bands; infrared and visible light; showed passive sterilization, and ultraviolet A and C showed differences in sterilization according to the pulse. In laser sterilization were differences that found according to the wavelength bands and pulses.

The Spatial Coherence Characteristics of Wavefront of NBUR Nd:YAG Laser Output Beam (NBUR Nd:YAG 레이저 위상파면의 공간적 가간섭성 특성)

  • 박대윤;최승호;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.288-295
    • /
    • 1995
  • We have studied about spatial wavefront analysis of a pulsed laser output beam by means of an imaging unstable ring resonator with an infinite Fresnel number. We have constructed a Newtonian telescope type NBUR (Negative Branch Unstable Ring) Nd:YAG laser with 4 plane mirrors. Provided that the NBUR resonator is under self imaging condition, the resonator could be reduced diffraction effects which were occuring to the beam transmitting through the circular aperture of scraper mirror in the resonator. We have observed enhancement in the spatial coherence of wavefronts of laser beam due to the iterative round trips of the self imaging beam inside the ring resonator. The information on the spatial wavefronts was determined by the fringe patterns from Mach-Zehnder interferometer and the fringe analysis by means of the Fourier transform method showed the distortion of wavefronts of less than 0.2), In comparison with a standing wave type resonator, we have confirmed that the spatial coherence of the NBUR Nd:YAG laser output beam was enhanced as much as 75%. s 75%.

  • PDF

Characteristics of $CO_2$ or Nd:YAG Laser Welded 600MPa Grade TRIP Steel (600MPa급 TRIP강의 $CO_2$ 및 Nd:YAG 레이저 용접부의 특성)

  • Han, Tae-Kyo;Kim, Seung-Jun;Lee, Bong-Keun;Kim, Dae-Up;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.24 no.1
    • /
    • pp.56-63
    • /
    • 2006
  • The characteristics of $CO_2$ or Nd:YAG laser welded 600MPa ade TRIP steel was investigated. He or Ar gas was used as a shield gas in case of $CO_2$ laser welding, but the shield gas was not used in case of Nd:YAG laser welding. Bead on plate welding was performed with various welding conditions. Defects in the joints of both welding type occurred at 1.8m/min but were not observed over the welding speed of 2.1m/min in case of Nd:YAG laser welding. However, porosity occurred in $CO_2$ laser welding and the tendency of decreasing with the increase of welding speed. The hardness was the highest at heat affected zone near fusion zone as well as at the fusion zone and decreased on approaching the base metal. In a perpendicular tensile test to the weld line, all specimens that have been welded at optimum conditions were fractured at the base metal, and the tensile properties showed the rather higher than those of raw material. In a parallel tensile test, the strength of the joints was higher than that of the base metal. Elongation was found to be lower than that of the raw material. Forming height by Erichsen test and elongation were deeply related with the ratio of base metal/weld metal and the maximum hardness of the weld metal. Also porosity induced to decrease the strength and the elongation. The maximum formability was recorded at approximately 80% as compared with that of the raw material with the optimum condition.

A Case of Tracheal Papillomas Treated With Bronchofibroscopic Nd-YAG Laser Therapy (기관지 내시경하 Nd-YAG Laser소각으로 치료 성공한 기관내 유두종)

  • Yoo, Jeong-Soo;Yoon, Soo-Mi;Kim, Mi-Oak;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Jung, Won-Sang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.857-862
    • /
    • 1999
  • In contrast to juvenile laryngeal papillomatosis, which occurs most often in children and teenagers and is usually self limited, soliatry papillomas in adults are one of uncommon tumors of airway, and have a higher incidence of cancer. They are caused by the respiratory infection of human papilloma virus(HPV). They could spread to more distal airways and have a tendency of recurrence after limited surgical excision. Recently endoscopic therapies such as Nd-YAG laser, electrocautery, and cryotherapy provide extremely effective treatment modalities. We report a case of solitary tracheal papillomas in a 48 year-old man who presented with cough, scanty hemoptysis, and functional evidence of central airway obstruction. He was successfully treated by a Nd-YAG laser therapy via fiberoptic bronchoscopy under the local anesthesia.

  • PDF

A Study on the Antibacterial Effects of Pulsed Nd: YAG Laser Irradiation to Streptococcus Mutans (Pulsed Nd : YAG Laser 조사의 Streptococcus mutans에 대한 효과)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 1997
  • In order to investigate the antibacterial effects of pulsed Nd:YAG Laser concerning to Streptococcus mutans, Streptococcus mutans was cultured and standardized and plated in 96 well plates. After that, black dye and chlorhexidine were applied and pulsed Nd:YAG Laser was irradiated to plates. Experimental groups which was applied with black dye and chlorhexidine were divided into 5 groups by concentration. And experimental groups and control group were subdivided as unlased and lased of 20, 40, and 60J. After laser irradiation, All groups were plated in agar plates and incubated for 18 hours. Bacterial colonies were counted and analysed comparitively, and the temperature of culture medium was measured on every laser irradiation. The results were obtained as follows; 1. In case of laser irradiation only, there is no significant reduction in number of Streptococcus mutans by irradiated energy of laser. 2. In case of black dye application, there is no difference by concentration of black dye but there is decrease when applied Laser and black dye simultaneously. 3. When applied chlorhexidine, the number of Streptococcus mutans was decreased according to increase of concentration, but there is no difference by irradiated energy of laser. 4. The temperature of culture medium was increased according to increase of irradiated energy of Laser, and the number of Streptococcus mutans was reduced remarkably just above 50 centigrade and killed above 70 centigrade. As above results, pulsed Nd:YAG Laser has well-absorbing affinity to black dye. And antibacterial effect of pulsed Nd:YAG Laser against Streptococcus mutans is seemed to be due to increase of temperature.

  • PDF

Study on the Core Loss Improvement of SiFe Plate in Relation with Laser Pulse Width in the Laser Scribing (레이저 스크라이빙에 있어서 레이저의 펄스폭에 따른 규소강판의 코어손실 개선 연구)

  • Ahn, Seung-Joon;Park, Chul-Geun;Ahn, Seong-Joon
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.320-324
    • /
    • 2005
  • The core loss of $3\%$ SiFe is strongly dependent on silicon content, impurities, permeability, and domain structure of the SiFe. Domain refining has been proved to be very good method for reduction of core loss in high permeability grain oriented SiFe, and laser scribing is well-blown as an effective and industrially important method of domain refinement. In this work, magnetic domain refinement has been carried out by using a pulsed Nd : YAG laser, and the core losses have been measured and analyzed to and optimal parameters of the laser treatment. The laser hem was focused with a spot size of $100{\mu}m$ and pulse energy of 10${\~}$35mJ and the lines were scribed with a period of ${\~}$5mm. The core loss was improved up to $17\%$ with 30 ns-Nd : YAG laser beam in $3\%$ SiFe.

Sequential Delivery of Neodymium:Yttrium-Aluminum-Garnet and Alexandrite Laser Pulses for Treating Light Brown Seborrheic Keratoses

  • Cho, Sung Bin;Oh, Doojin;Yoo, Kwang Ho
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.24-27
    • /
    • 2019
  • Seborrheic keratoses (SKs) have been treated with non-ablative longpulsed (LP) lasers, including LP 532-nm neodymium (Nd): yttrium aluminum garnet (YAG), LP 695-nm ruby, LP 755-nm alexandrite (Alex), and LP 1,064-nm Nd:YAG lasers, with a pulse durations of 1-300 msec. Dual-wavelength LP 755-nm Alex/1,064-nm Nd:YAG laser systems have been used to remove hair follicles and treat various vascular and pigmented disorders by sequentially delivering two pulses of different wavelengths with interpulse intervals in the millisecond range. This paper reports the case of a female patient with multiple, discrete, light brown SKs on the dorsum of both hands that were treated effectively with one session of dual-wavelength LP 1,064-nm Nd:YAG/755-nm Alex laser treatment. The treatment settings for the LP Nd:YAG laser were comprised of a wavelength of 1,064 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. The settings for the LP Alex laser were comprised of a wavelength of 755 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. A hybrid mode was used to automatically deliver LP Nd:YAG and LP Alex laser pulses in succession at interpulse intervals of 20 msec. Six weeks after treatment, the patient exhibited remarkable improvement of the light brown seborrheic keratoses and was satisfied with the results.