Mass Flow Rates and Performance of Natural Smoke Ventilators in High-rise Buildings (초고층건물에서 배연창의 풍량해석 및 배연성능)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.91-97
    • /
    • 2009
  • The mass flow rates and performance of natural smoke ventilators in high-rise buildings with 40, 80, 120 stories were evaluated using CONTAMW tool. The results showed that only limited part of smoke ventilators can have positive exhaust flow in high-rise buildings due to stack effect and wind velocities. In the higher story buildings larger stack effect can overcome outside strong wind effect to give more ventilation performance. The air tightness of the building have strong effect on the exhaust performance of the ventilators to give lower performance with loose air tightness of the exterior walls.

The effects of scour depth and riverbed condition on the natural frequencies of integral abutment bridges

  • Akbari, Reza;Maadani, Saeed;Abedi, Alireza;Maalek, Shahrokh
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.2
    • /
    • pp.85-101
    • /
    • 2019
  • The effects of foundation scour depth and riverbed condition on the natural frequencies of a typical cross-river integral abutment bridge have been studied. The conventional operational modal analysis technique has been employed in order to extract the modal properties of the bridge and the results have been used in the Finite Element (FE) model updating procedure. Two tests have been carried out in two different levels of water and wet condition of the riverbed. In the first test, the riverbed was in dry condition for two subsequent years and the level of water was 10 meter lower than the natural riverbed. In the second test, the river was opened to water flow from the upstream dam and the level of water was 2 meter higher than the natural riverbed. The results of these two tests have also been used in order to find to what extend the presence of water flow in the river and saturation of the surrounding soil affect the bridge natural frequencies. Finally, the updated FE model of the bridge has been applied in a series of parametric analyses incorporating the effect of piles' relative scour depth on the bridge natural frequency of the first four vibration modes.

Dam Effects on Spatial Extension of Flood Discharge Data and Flood Reduction Scale I (홍수 유출자료의 공간확장과 홍수저감효과에 대한 댐 영향 분석 I)

  • Kim, Nam Won;Jung, Yong;Lee, Jeong Eun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.209-220
    • /
    • 2015
  • In this study, the effects of changed environment on spatial extension of flood discharge data which is generating discharge data at ungauged watersheds. Especially, effects of dams on spatial extensions of flood discharge data and on natural flow generation were studied. This is somehow an intial trial of flood discharge data generation for heterogeneous watersheds because of dam installation. Data extensions have been performed based on the flood discharge data from YeoJoo water gauge station located on the Nam-Han River. For the evaluation of flood discharge data spatial extension under dam effects and producing natural flow, 41 flood events associated with YeoJoo water gauge station were selected from 1986 to 2010. When flood discharge data were extended based on YeoJoo water gauge station, 77% of selected flood events were over the satisfaction ranges (NSE>0.5) of Nash-Sutcliffe Efficiency for model validation. Extended flood discharge data at Yangpyung has 0.84 NSE obtained from spatial data extension based on YeoJoo water gauge station. Generated natural flow at YeoJoo was influenced strongly by Chungju Dam which has larger effects on streamflow at YeoJoo than Hoangsung Dam. Observed peak discharges after the 1986 of Chungju Dam installation were smaller than those of the obtained natural flow. Through these results, spatial extension of flood discharge data with installed dams works efficiently for ungauged watersheds and natural flow can be generated using extended flood discharge data.

A Study on Effects of Temperature Difference between the Inside and Outside the Meter-Run on Natural Gas Flow Measurement Errors (천연가스 계량배관 내$\cdot$외의 온도차가 계량오차에 미치는 영향에 관한 연구)

  • Ha Youngcheol;Lee Chulgu;Chang Seungyong;Lee Kangjin
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.83-89
    • /
    • 1998
  • Experiments had been conducted Qualitatively regarding flow measurement errors of orifice flowmeter due to temperature difference between the inside and outside the natural gas meter-run in case of no pipe insulations. The primary factors considered in this study are fluid velocity and surrounding temperature. In addition, a portion of thermal radiation due to the sun was involved as a factor. The results showed that the considerable errors were not detected even in conditions of low flow rates and large temperature difference between the inside and outside the meter-run.

  • PDF

A Study on the Estimation of River Management Flow in Urban Basin (도시유역의 하천유지용수 산정에 관한 연구)

  • 이영화
    • Journal of Environmental Science International
    • /
    • v.5 no.3
    • /
    • pp.377-385
    • /
    • 1996
  • This study aims at the estimation of a river management flow in urban basin analyzing Sinchun basin to be the tributary of Kumho river basin. The river management flow has to satisfy a low flow as natural flow and an environmental preservation flow estimated by a dilution flow to satisfy a target water quality in drought flow. Therefore for the estimation of a river management flow in Sinchun in this study, first Tank model as a basin runoff model estimates a low flow, a drought flow from a flow duration curve in Sinchun, second QUAL2E model as water quality model simulates water quality in Sinchun and estimates environmental preservation flow to satisfy a target water qua%its, BOD 8 mg/l by a dilution flow derived from Kumho river, Nakdong river and around water. And the river management flow is estimated by addition of a use flow and a loss flow to more flow between a low-flow and an environmental preservation flow.

  • PDF

Sensitivity Analysis of High and Low Flow Metrics to Climate Variations

  • Kim, Jong-Suk;Jang, Ho-won;Hong, Hyun-Pyo;Lee, Joo-Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.355-355
    • /
    • 2018
  • Natural hydrology systems, including high flow and low flow events, are important for aquatic ecosystem health and are essential for controlling the structure and function of ecological processes in river ecosystems. Ecosystem responses to flow changes have been studied in a variety of ways, but little attention has been given to how episodic typhoons and atmospheric circulation patterns can change these hydrologic regime-ecological response relationships. In this diagnostic study, we use an empirical approach to investigate the salient features of interactions between atmospheric circulation, climate, and runoff in the five major Korean river basins.

  • PDF

Thermal Conductivity Analysis of Amorphous Silicon Formed by Natural Cooling: A Molecular-dynamics Study

  • Lee, Byoung Min
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.3
    • /
    • pp.295-300
    • /
    • 2016
  • To investigate the thermal conductivity and the structural properties of naturally cooled excimer-laser annealed Si, molecular-dynamics (MD) simulations have been performed. The thermal conductivity of crystalline Si (c-Si) was measured by direct method at 1000 K. Steady-state heat flow was measured using a stationary temperature profile; significant deviations from Fourier's law were not observed. Reliable processes for measuring the thermal conductivity of c-Si were presented. A natural cooling process to admit heat flow from molten Si (l-Si) to c-Si was performed using an MD cell with a size of $48.9{\times}48.9{\times}97.8{\AA}^3$. During the cooling process, the temperature of the bottom $10{\AA}$ of the MD cell was controlled at 300 K. The results suggest that the natural cooling system described the static structural property of amorphous Si (a-Si) well.

Experimental study of natural convection for magnetic fluids in annular pipes (이중원관내 자성유체의 자연대류에 관한 실험적 연구)

  • Park, Joung-Woo;Lee, Jun-Hee;Seo, Lee-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.191-195
    • /
    • 2001
  • The applications of magnetic fluid can be normally made by 1) using changes of a property of matter caused by applied magnetic field; 2) preserving magnetic fluid at a certain position or in a magnetic fluid keeping the body in a floating condition; 3) controlling the flow of magnetic fluid by means of magnetic field. However, these are usually made by using their methods together. In this study, the natural convection flow of a magnetic fluid in annular pipes is experimentally analyzed. High temperature is kept constantly inside of a circular pipe of experimental model, on the other hand, low temperature is kept constantly outside of it. In experiments, several cases are carried out in order to clarify the fluence of direction and intensity of magnetic fields on the natural convection of magnetic fluid. Therefore magnetic fields are applied in various intensity and up and down directions by permanent magnets.

  • PDF

Improvement of Natural Ventilation in a Factory Building Using PIV Technique (PIV 풍동실험을 통한 공장건물의 자연환기 향상 연구)

  • Kang Jong-Hoon;Lee Snag-Jeon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.46-49
    • /
    • 2005
  • Vents at outer walls of a large factory building are very important for natural ventilation. But, if a full-open vent is used, rain comes through the vents. We tried to utilize the natural ventilation effectively using a louver. A 1/120 scale-down building model was placed inside an atmospheric boundary layer simulated in a wind tunnel test section. The effect of louver angle on the ventilation flow inside the factory building was investigated experimentally. Instantaneous velocity fields inside the building model were measured using a 2-frame PIV system with varying the louver angles ($\theta=20^{\circ},\;40^{\circ},\;60^{\circ}$). For the case of $\theta=60^{\circ}$, as the incoming flow into the factory building increases, the inside velocity distribution becomes uniformly.

  • PDF

ANALYSIS OF A STRATIFIED NATURAL CONVECTION FLOW WITH THE SECOND-MOMENT CLOSURE (이차모멘트 난류모델을 사용한 성층화된 자연대류 유동 해석)

  • Choi, Seok-Ki;Kim, Seong-O
    • Journal of computational fluids engineering
    • /
    • v.12 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • A computational study on a strongly stratified natural convection is performed with the elliptic blending second-moment closure. The turbulent heat flux is treated by both the algebraic flux model (AFM) and the differential flux model (DFM). Calculations are performed for a turbulent natural convection in a square cavity with conducting top and bottom walls and the calculated results are compared with the available experimental data. The results show that both the AFM and DFM models produce very accurate solutions with the elliptic-blending second-moment closure without invoking any numerical stability problems. These results show that the AFM and DFM models for treating the turbulent heat flux are sufficient for this strongly stratified flow. However, a slight difference between two models is observed for some variables.