• Title/Summary/Keyword: Natural discharge

Search Result 385, Processing Time 0.03 seconds

Limnological Characteristics of the River-type Paltang Reservoir, Korea: Hydrological and Environmental Factors (하천형 저수지 팔당호의 육수학적 특성:수문과 수환경 요인)

  • Shin, Jae-Ki;Kang, Chang-Keun;Kim, Ho-Sub;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.242-256
    • /
    • 2003
  • This study aimed to determine the relationship between rainfall-discharge patterns and maior aquatic environmental factors in a river-type reservoir. Specifically, daily monitoring was conducted in Paltang Reservoir from January 1999 to December 2001. Observation of the daily changes of the environment factors showed that natural meteorological factors and hydrological factors causing the change of water discharge had a major effect on the aquatic environment. Rainfall was the main source of hydrological changes, with its frequency a possible direct variable governing the range of discharge changes. Rainfall was weak in November${\sim}$May and heavy in June${\sim}$October (heavist in summer). The range of water discharge was greatest during summer (July to September) and lowest during winter (January to February). A principal component analysis (PCA) showed that aquatic environmental factors could be classified into three different types in the pattern of annual variation. First, type I included water temperature, turbidity, water color and organic matter (COD), which increased with increasing water discharge. Second, type ll consisted of DO and pH, which decreased with increasing water discharge. Third, type III included conductivity, alkalinity and chloride ion, which showed middle values with increasing water discharge. Monthly variation of aquatic environments explained by the first two dimensions of the PCA suggests that aquatic environments of Paltang Reservoir may have annual cycle typical of river-type reservoirs depending on hydrological factor such as water discharge.

A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE (보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구)

  • Shin, Doo-Seong;Jeon, Seung-Ik;Lee, Jun-Ho;Yun, Do-Hong;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF

Effects of Heated Effluents on the Intertidal Macroalgal Community near Uljin, the East Coast of Korea (동해안 울진원전의 온배수 방출이 주변 해조군집에 미치는 영향)

  • Kim, Young-Hwan;Ahn, Jung-Kwan;Lee, Jae-Il;Eum, Hee-Moon
    • ALGAE
    • /
    • v.19 no.3
    • /
    • pp.257-270
    • /
    • 2004
  • In order to clarify the structure and seasonal dynamics of warm tolerant benthic marine algal community in Korea, the species composition and biomass of marine algae at the discharge canal of Uljin nuclear power plant on the East Coast of Korea were investigated seasonally from February 1992 to October 2000. 107 species of marine algae were found at the discharge canal during the past nine years. In general, the number of species observed was abundant in spring or summer and less in autumn or winter. 27 species (4 blue-green, 5 green, 6 brown and 12 red algae) of marine algae occurred more than 1/ 6 frequency and thus can be categorized as warm tolerant species. Among these, one brown (Dictyota dichotoma) and four red algae (Gelidium amansii, Anphiroa ephedraea, Hydrolithon sargassi, Marginisporum crassissimum) are recorded as warm tolerant marine algae for the first time in Korea. Padina arborescens, Anphiroa zonata and Corallina pilulifera were common species found more than 75% frequency. Seasonal fluctuations of mean biomass were 0-1,330 g dry wt m^(-2) and dominant species in biomass were Corallina pilulifera (contribution to a total biomass proportion 34%), Anphiroa zonata (23%), Padina arborescens (18%) and Sargassum micracanthum (11%). The red algae appeared as predominant algal group at the discharge canal of Uljin nuclear power plant in the qualitative and quantitative aspects. The green algae such as Enterornorpha compressa appeared rather frequently at the discharge canal, but the biomass proportion was very low, in contrast to Kori nuclear power plant where there was definite green algal dominance. Differences in algal communities developed at the discharge canals of Uljin and Kori nuclear power plant on the East Coast of Korea, particularly biomass proportions of green algae, can probably be related to local environmental factors such as water velocity through the canal and natural seawater temperatures.

Reduction Effect of CO2 Discharge of Green PC (그린 PC의 탄소(CO2) 배출량 감축효과)

  • Kim, Young-Geil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.2
    • /
    • pp.115-121
    • /
    • 2014
  • Since the rapid development of information age and information technology might be considered to cause environmental problems, Green IT is perceived as core technology for low carbon green growth and the minimum waste of electricity. In this vein, Green IT is becoming new paradigm of focusing on natural environment. This study examines current various IT required for green growth, and studies various methods for diminution of carbon discharge in Korea and other countries. Especially, it focuses on the diminution effect of carbon discharge by using Green PC, and compares the difference of voltage, voltaic current, and the use of electricity between Normal PC and Green PC by using HPM-300A, and measures carbon discharge of Normal PC and Green PC. The result shows that the diminution effect of $CO_2$ discharge of Green PC is amount to 11.5Kg per year, and the effect of green growth is up to the conservation of 2 or 3 pine trees.

Sewage Treatment Using Natural Systems and Effluent Reuse for Crop Irrigation in Small Communities

  • Ham, Jong-Hwa;Yoon, Chun-G.;Jeon, Ji-Hong;Hwang, Ha-Sun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.70-82
    • /
    • 2003
  • A pilot study was performed from July 1998 to December 2002, including winter performance, to examine seasonal performance of a constructed wetland and subsequent pond system for treatment of sewage in small communities of Korea. Pond was operated as a intermittent-discharge pond during winter period, and continuous flow system during growing season; its effects was evaluated from December 2001 to April 2003. The subsurface flow (SSF) wetland was satisfactory for treating sewage with good removal efficiency even during the winter period. The wetland effluent concentrations of $BOD_5$ and TSS were often higher in winter than in the growing season, but this was explained by the higher loading rates, rather than lower removal efficiency. The relatively poor-quality wetland effluent was further polished during winter in the pond. The upper layer of the pond water column became remarkably clear immediately after ice melt. In the growing season, ponds could be operated as a continuous flow system to remove nutrients and pathogens, and the effluent of pond could be reused as a supplemental irrigation water without risk of infection by sewage-borne pathogens as well as causing adverse effect on growth and yield. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the intermittent-discharge pond was found to be effective for further polishing if necessary. Therefore, the combination of a wetland and subsequent pond system and reuse of effluent as crop irrigation water is recommended as a practical alternative to treat sewage in Korean small communities, and partial discharge of pond water in March is suggested.

PD Signal Time-Frequency Map and PRPD Pattern Analysis of Nano SiO2 Modified Palm Oil for Transformer Insulation Applications

  • Arvind Shriram, R.K.;Chandrasekar, S.;Karthik, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.902-910
    • /
    • 2018
  • In recent times, development of nanofluid insulation for power transformers is a hot research topic. Many researchers reported the enhancement in dielectric characteristics of nano modified mineral oils. Considering the drawbacks of petroleum based mineral oil, it is necessary to understand the dielectric characteristics of nanofluids developed with natural ester based oils. Palm oil has better insulation characteristics comparable to mineral oil. However very few research reports is available in the area of nanofluids based on palm oil. Partial discharge (PD) is one of the major sources of insulation performance degradation of transformer oil. It is essential to understand the partial discharge(PD) characteristics by collecting huge data base of PD performance of nano modified palm oil which will increase its confidence level for power transformer application. Knowing these facts, in the present work, certain laboratory experiments have been performed on PD characteristics of nano $SiO_2$ modified palm oil at different electrode configurations. Influence of concentration of nano filler material on the PD characteristics is also studied. Partial discharge inception voltage, Phase resolved partial discharge (PRPD) pattern, PD signal time-frequency domain characteristics, PD signal equivalent timelength-bandwidth mapping, Weibull distribution statistical parameters of PRPD pattern, skewness, repetition rate and phase angle variations are evaluated at different test conditions. From the results of the experiments conducted, we came to understand that PD performance of palm oil is considerably enhanced with the addition of $nano-SiO_2$ filler at 0.01%wt and 0.05%wt concentration. Significant reduction in PD inception voltage, repetition rate, Weibull shape parameter and PD magnitude are noticed with addition of $SiO_2$ nanofillers in palm oil. These results will be useful for recommending nano modified palm oil for power transformer applications.

Transition of Pumping Technology, Irrigation Water Requirement, and Unit Area Drainage Discharge at Pumping Station-based Irrigation Associations in South Korea during Japanese Colonial Period (in Review) (일제하 양배수장형 수리조합에서의 양수기술과 단위용·배수량의 변천 (리뷰 논문))

  • Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.3
    • /
    • pp.59-73
    • /
    • 2021
  • The purpose of this study is to investigate transition of pumping technology, irrigation water requirement, and unit area drainage discharge at the Pumping station-based Irrigation Associations (PIAs) in South Korea during Japanese colonial period (1910-1945). The PIAs established pumping stations and embankments along rivers for the purpose of irrigation, drainage and flood prevention until the mid-1920s. From the late 1920s after major river improvement projects, newly established PIAs did not include the flood prevention in their purpose of establishment. The design criteria of the irrigation and drainage projects, such as irrigation water requirements, design rainfall, and allowable ponding duration were decided according to the circumstances of PIAs. The gross irrigation water requirement of paddy fields increased from the 1920s to the 1940s, and reached the level of 0.0020 m3/s/ha (19 mm/d) in the 1940s for the fairly good irrigation status in the drought. The great floods of 1930, 1933, and 1934 triggered the increase in drainage discharge in the late 1930s, leading to the unit area drainage discharge of 0.9-2.6 m3/s/km2 for natural drainage and 0.3-1.1 m3/s/km2 for pump drainage. Therefore, several PIAs near the major rivers could avoid repetitive floods damage.

Experimental Study on the Blade Excitation Frequency for the Natural Frequence of Centrifugal Pump Piping Systems (원심펌프 배관계 진동에 영향을 주는 블레이드 가진주파수의 실험적 고찰)

  • 김윤제;신호길
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.335-341
    • /
    • 2001
  • Pressure pulsations generated by the blade-tongue interaction induce vibration of the piping systems and the structure connected to pumps, resulting in the severe noise and fatigue fracture. Experiments were made on the natural frequencies of liquid columns in piping systems with a single suction, single stage, centrifugal volute pump. Experimental results show that the natural frequencies of the liquid columns in the pump piping systems depend on the dimensions of the pipes and the impeller shapes, and are not affected substantially by the rate of discharge and the rotating speed of the pump.

  • PDF

Characteristics of TVOCs Emission Factors from Chemical and Natural Coating Materials (화학 및 천연페인트에서 발생되는 TVOCs의 방출강도 특성 연구)

  • Kim Shin Do;Kim Jeong Ho;Park Jin Soo;Lee Jeong Joo
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.487-492
    • /
    • 2004
  • Building materials are composed of very complex chemical compounds, and these indoor building materials discharge very much Volatile Organic Compounds(VOCs). We performed the environmental chamber test to investigate the Total VOCs(TVOCs) emission characteristics and emission factors about chemical and natural coating materials. As the result, we concluded that TVOCs emission are high at initial time and decreased in course of time. Natural paint was low emission level for TVOCs than chemical paint by small chamber test. The TVOCs emission factor-time profile showed a good fit with the results from the measured and predicted value.

A Forensic Engineering Study on Bursting Accident of Composite Pressure Vessel in CNG Bus (CNG버스 복합재 압력용기 파열사고에 관한 법공학적 연구)

  • Kim, Eui-Soo;Kim, Jin-Pyo;Park, Nam-Kyu;Kim, Youn-Hoi
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.15-21
    • /
    • 2008
  • The bus using compressed natural gas(CNG) trend to be extended in use internationally as optimal counter-plan for reducing discharge gas of light oil due to high concern about environment. But, Composit pressure vessels(CPV) to be equipped with CNG bus is always involved in the point that safety accidents happen due to having compressed natural gas. In this report, we analysis the cause of CPV bursting accident by reviewing design and manufacture factor and suggest preventive measure through this case.