• 제목/요약/키워드: Natural Ventilation

검색결과 427건 처리시간 0.023초

주기적인 외부 압력변동에 의한 자연환기성능 연구 (A Study on Natural Ventilation Performance by Periodic Outdoor Pressure Fluctuations)

  • 이승연;염철민;한화택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.27-32
    • /
    • 2005
  • This paper investigates the effects of outdoor pressure fluctuations on natural ventilation through openings of a building envelope. The ventilation airflow rate depends on the magnitude and the period of the pressure fluctuations, the size of the opening compared to the space volume, and the resistance characteristics of the opening. Non-dimensional parameters have been derived, which determine indoor pressure responses due to outdoor pressure fluctuations. The flow regions are categorized into synchronized region, opening resistance region, and transition region depending on the non-dimensional parameters.

  • PDF

학교 교실의 창호 환기 조절 모드에 따른 자연형 냉방효과 연구 (A Study on the Natural Cooling Effect by Ventilation Control Mode of Window at School Classroom)

  • 이효석;김순호;최정민
    • 한국태양에너지학회 논문집
    • /
    • 제38권4호
    • /
    • pp.67-76
    • /
    • 2018
  • Cooling the building by natural ventilation is one of the passive methods widely used from ancient times. It can be effectively applied especially in case of cooling load during the intermediate season of the year. In this study, the effect of 4 cases of window ventilation control mode which are 'Always Close', 'Temperature', 'Enthalpy' and 'Always Open' is simulated by Energyplus program and analyzed to improve the comfort of occupants and reduce energy consumption of the school classroom.

실내 미세먼지 저감을 위한 창호형 환기시스템 성능평가 (Performance Evaluation of Window Ventilation System for Reducing Indoor particulate matter)

  • 양영권;박진철
    • 토지주택연구
    • /
    • 제10권3호
    • /
    • pp.1-7
    • /
    • 2019
  • Indoor particulate matter(PM) is a carcinogen and needs to be removed and managed. It is generally reduced and removed through ventilation and filtration. Owing to the recent occurrence of high-concentration fine dust and yellow dust in the atmosphere, however, it is difficult to expect the purification of indoor air through the simple introduction of the outside air. For residential buildings, in particular, they are highly dependent on natural ventilation but the lack of natural ventilation is worsening because concerns over the inflow of external pollutants are increasing. Therefore, this study designed and manufactured a window ventilation system that does not require a duct to improve the maintenance and management problems of general ventilation system, and constructed indoor PM concentration change data through performance evaluation.

양파 간이저장시 통풍조건 및 통풍구 재료의 크기가 저장에 미치는 영향 (Effects of Ventilation Condition and Ventilating Hole Sizes to Improve Quality Onion(Allium cepu. L) under Room Temperature)

  • 이찬중;김희대;정은호;김우일;서전규
    • 한국식품저장유통학회지
    • /
    • 제8권4호
    • /
    • pp.356-361
    • /
    • 2001
  • 양파 간이저장시 노지야적에 의해 발생하는 부패를 감소시켜 망과의 안전저장을 위하여 조립식 간이하우스를 이용하여 통풍조건 및 통풍구 재료의 크기에 따른 저장성을 조사한 결과는 다음과 같다. 평균온도는 노지야적에 비해 강제통풍에서 0.3~3.6$^{\circ}C$높았고, 무통풍에 비해서는 1.4~8.2$^{\circ}C$가 낮았다. 그러나 처리간 유의차는 없었다. 상대습도는 통풍처리구에서 무통풍 및 노지야적에 비해 약간 높았다. 구중감소율은 노지야적에서는 2.5%, 무통풍에서는 2.9%, 자연통풍 2단에서는 3%, 강제통풍 2단에서는 4.3%였다. 8월 하순까지의 부패율은 자연통풍 2단 27.7%, 강제통풍 2단 25.4%,인데 비해 무통풍 34.6%, 노지야적 37.8%로 통풍처리구에서 부패가 적었다. 통붕구 재료의 크기가 클수록 평균기온은 조금 낮았고, 상대습도는 7월에 조금 높은 경향을 보이다가 8월 이후에는 차이가 거의 없었다. 통풍 파이프 표면의 풍속은 통풍구의 크기가 작을수록 강했으며, 부위별로는 중간부위가 양끝쪽보다 낮았다. 부패율은 75mm통풍구 17.9%, 100mm통풍구 15.3%, 125mm통풍구 14.1%로 통풍구 크기가 클수록 부패는 적었다.

  • PDF

자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구 (A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation)

  • 전주영;김길태;김선동
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.325-332
    • /
    • 2014
  • 본 연구에서는 창문형 자연환기장치가 설치된 7개 세대의 소형공동주택($33m^2{\sim}51m^2$)을 대상으로 Blower Door를 이용한 현장 기밀성능 및 공기유동 성능을 측정하였다. 창문형 자연환기장치는 외기에 면하는 모든 창호 및 거실분합문에 설치되어 있으며, 수동 개폐형 장치가 설치되어있다. 본 연구에서는 자연환기장치와 창호의 개폐여부에 따라서 6개의 CASE를 설정하여 실측하였다. 측정결과, 자연환기장치와 모든 개구부를 밀폐한 상태의 기밀성능 값(CASE1)은 1.77~3.12ACH로 평균 2.27ACH로 나타났으며, 문헌조사 결과 자연환기장치가 설치되지 않은 일반 공동주택(1.65~4.28ACH)과 유사하게 나타났다. 내외측의 자연환기장치를 모두 열었을 때의 공기유동성능 값(CASE6)은 평균 5.87ACH로 나타나 밀폐조건과 비교하여 평균 3.6ACH가 증가하는 것으로 나타났다. 외측 환기장치와 창호를 밀폐한 조건에서 내측 환기장치만 개방시와 내측창을 개방시의 공기유동성능값의 차이는 평균 0.29ACH로 내측창호 개방시의 기밀성능 값이 높게 나타났다. 반대로 내측 환기장치와 창호를 밀폐한 조건에서 외측 환기장치만 개방시와 외측창 개방시의 차이는 평균 0.30ACH로 외측창호 개방시가 높게 나타났다. 내측창호만의 공기유동성능과 외측창호만의 공기유동성능 측정값의 차이는 0.77ACH로 내측창호가 더 우수하게 나타났다. 향후에는 자연환기장치와 창호 및 새시의 종류에 따른 기밀성능의 추가 측정을 통해 정량적 상관관계 조사가 필요할 것으로 판단된다.

루버를 이용한 대형공장 내부 자 연환기유동 개선에 관한 연구 (Improvement for Natural Ventilation Flow inside a Large Factory Building Using Louver-t ype Ventilator)

  • 강종훈;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.705-706
    • /
    • 2008
  • When heat generated inside a large factory building is not discharged due to a stagnant flow, the working environment of workers becomes worse and the cooling of high-temperature products such as hot-rolling coils is delayed. To investigate the natural ventilation inside a large factory building, experimental studies were carried out using wind-tunnel tests. The scale-down factory building models were placed in an atmospheric boundary layer (ABL) and the mean and fluctuating velocity fields were measured using a particle image velocimetry (PIV) technique. For the prototype factory model, the outdoor air is only entrained into the factory building through the one-third open windward wall, and stagnant flow is formed in the rear part of the target area. In order to improve the indoor ventilation environment of the factory building, three different louver-type ventilators were attached at the upper one-third open windward wall of the factory model. Among the three louver ventilators tested in this study, the ventilator model #3 with the outer louver (${\theta}_o$ = 90$^{\circ}$) and the inner louver (${\theta}_i$ = -70$^{\circ}$) was found to improve the natural ventilation inside the factory building model effectively. The flow rate of the entrained air was increased with aligning the outer louver blades with the oncoming wind and guiding the entrained air down to the ground surface with elongated inner louver blades.

  • PDF

A PRELIMINARY STUDY OF EFFECT OF THE GREEN FEATURE - WING WALLS ON NATURAL VENTILATION IN BUILDINGS

  • Cheuk Ming Mak;Jian Lei Niu;Kai Fat Chan
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.814-819
    • /
    • 2005
  • There is growing consciousness of the environmental performance of buildings in Hong Kong. The Buildings Department, the Lands Department and the Planning Department of the Hong Kong Government issued the first of a series of joint practice notes [1] to promote the construction of green and innovative buildings. Green features are architectural features used to mitigate migration of noise and various air-borne pollutants and to moderate the transport of heat, air and transmission of daylight from outside to indoor environment in an advantageous way. This joint practice note sets out the incentives to encourage the industry in Hong Kong to incorporate the use of green features in building development. The use of green features in building design not only improves the environmental quality, but also reduces the consumption of non-renewable energy used in active control of indoor environment. Larger window openings in the walls of a building may provide better natural ventilation. However, it also increases the penetration of direct solar radiation into indoor environment. The use of wing wall, one of the green features, is an alternative to create effective natural ventilation. This paper therefore presents a preliminary numerical study of its ventilation performance using Computational Fluid Dynamics (CFD). The numerical results will be compared with the results of the wind tunnel experiments of Givoni.

  • PDF

전력구 터널 내 전력선 발열 시 환기방식에 따른 온도분포에 대한 전산해석 (Numerical Simulation on the Temperature Distribution by Ventilation Type during Heat of the Power line in Electric Power Tunnel)

  • 이호형;이승철;곽동걸;백두산
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.3-4
    • /
    • 2014
  • Power line in electric power tunnel generate heat around during power transmission. Rising temperature inside the electric power tunnel reduces the transmission efficiency of the power line. In this study, trying to understand the change in temperature in the electric power tunnel by forced ventilation and natural ventilation when the temperature rise of the electric power tunnel. The results show that average temperature in electric power tunnel by natural ventilation, forced ventilation is $56.55^{\circ}C$, $23.25^{\circ}C$. Therefore electric power tunnel during power transmission needs cooling or ventilation system.

  • PDF

동굴처분 방식을 사용하는 방사성 폐기물 처분장의 자연 환기 타당성 평가 (The Feasibility of Natural Ventilation in Radioactive Waste Repository Using Rock Cavern Disposal Method)

  • 김진;권상기
    • 방사성폐기물학회지
    • /
    • 제3권3호
    • /
    • pp.183-192
    • /
    • 2005
  • 자연환기는 처분장의 작업 환경 및 위생, 부유 방사성 핵종의 노출 등과 같은 안전문제에 있어 자연환기 자체만으로는 기계적 강제 환기에 비해서 덜 효과적이지만 처분장 내의 수분제거, 작업 환경 조성과 관련하여 라돈 (Rn) 가스의 희석과 같은 향후 처분장의 장기적 환경을 위해서는 중요한 역할을 할 수 있고, 환풍기와 같은 환기 설비를 이용해야하는 기계환기에 비해 경제적으로 매우 효과적 일수 있다. 본 논문에서는 지하 처분장의 건설 및 운영 기간동안 자연환경 조건에 따라 처분장에 스스로 생기는 자연 환기의 타당성에 대하여 기술하였다. 자연 동굴을 통한 자연환기 유사에 의해 밝혀진 증거들과, 수직갱을 갖는 산악 도로터널에서의 자연 환기 측정, 그리고 주어진 자연환기 압력에 의한 공기 발생량 계산 등을 통해서 자연 환기는 한국형 지하 방사성 폐기물 처분장에 잠재적으로 매우 유익함을 알 수 있다. 효과적으로 유도된 자연 환기는 방사성 폐기물 처분장 내에 발생하는 열과 습도, 그리고 라돈 가스를 제어하기에 경제적으로 좋은 방법이 될 수 있다. 자연환기를 통해 처분장의 전반적 열적 특성은 개선될 수 있고, 수분으로 포화된 공기는 효과적으로 건조되고 그 건조상태 유지 기간은 확장 될 수 있을 것이다.

  • PDF

지하처분장내 고준위 방사성 폐기물 발열량에 따른 자연환기력 연구 (A Study on Natural Ventilation by the Caloric Values of HLW in the Deep Geological Repository)

  • 노장훈;최희주;유영석;윤찬훈;김진
    • 터널과지하공간
    • /
    • 제21권6호
    • /
    • pp.518-525
    • /
    • 2011
  • 본 연구에서는 고준위 방사성 폐기물 처분장의 특징인 높은 고도 차이와 폐기물에서 발생하는 발열량에 따른 자연 환기력을 계산하고 이를 바탕으로 자연 환기량을 계산하였다. 고준위 방사성 폐기물 처분장은 열엔진과 유사한 폐쇄 싸이클의 열역학적인 과정을 따른다고 볼 수 있다. 지하처분장내 고준위 폐기물의 발열에 의한 열이 공기에 추가되고 이로 인해 공기가 upcast 수직갱을 통해 위로 올라가는 동안 팽창됨에 따라 주위에 일을 하고, 이때 한 일에 의해 첨가된 열의 일부분은 임시로 기계적 에너지로 변함으로서 공기의 흐름을 촉진할 수 있다. 이는 처분장 내에서 지속적이고 강력한 열원이 존재한다면 자연 지속적인 공기의 싸이클적 흐름을 가능하게 할 것이다. 이를 바탕으로 고준위 방사성 폐기물의 심지층 처분시 발생되는 자연 환기량을 수학적 방법으로 계산한 결과 굴뚝효과에 의하여 폐기물 발열량에 따라 $74{\sim}183$Pa의 자연 환기력이 계산되고 이에 따른 자연 환기량은 $92.5{\sim}147.7m^3/s$이 계산되었다. 또한 CFD의 자연환기량 해석결과는 $82{\sim}143m^3/s$로서 수학적인 방 법과 비교하여 매우 비슷한 결과를 나타내었다.