• 제목/요약/키워드: National fire protection code

검색결과 22건 처리시간 0.018초

방화설비계통 설계용 전산소프트웨어 개발에 관한 연구 (A Study on the Development of Computer Software for the Design of Fire Protection System)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.275-284
    • /
    • 1998
  • Standard on the carbon dioxide extinguishing system was prepared by the committed of the national fire protection assocition(NFPA)in USA on 1980. And this code is also applied to the design of a marine fire extinguishing system The most important problem in design is the uniform discharge of $CO_2$ through each nozzle from the high pressure $CO_2$ storage facility. The purpose of this paper is to develop the computer software to design the marine fire protection piping system. By solving the continuity equation energy equation and Bernoulli's equation simulataneously the flowrate in branch pipelines and discharge nozzles can be calculated.

  • PDF

초고층 건축물 소방안전관리의 기본방향에 관한 연구 (A Study on the general direction of Fire-Fighting Safety management in high-rise buildings)

  • 최만철;김병석
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.67-75
    • /
    • 2011
  • Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.

Predicting on Human-caused Forest Fire Occurrence in South Korea

  • Chae, Hee Mun;Lee, Chan yong
    • 한국산림과학회지
    • /
    • 제95권2호
    • /
    • pp.160-167
    • /
    • 2006
  • Most of the forest fires that occur in South Korea are caused by human. We partitioned South Korea into nine districts and used observed weather data and daily fire occurrence records for the 1994 to 2003 period to develop a human-caused fire occurrence model of South Korea. Logistic regression analysis techniques were used to relate the probability of a fire day to Fine Fuel Moisture Code (FFMC) component of the Canadian Forest Fire Danger Rating System. The probability of the number of fire day was increased as FFMC increased in the nine districts of South Korea.

거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구 (A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System)

  • 허예림;김윤성;김혜원;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF

COMPARISON OF DESIGN & PERFORMANCE OF SPRINKLER SYSTEM IN KOREA FIRE CODE AND NATIONAL FIRE CODE

  • Kim, Won-K
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.610-616
    • /
    • 1997
  • One of the notable changes in Korean Industry in 1990's was globalization. Many of Korea plants have been built In the foreign countries and many of foreign plants have been build in Korea. And it is believed that many foreign insurance companies will begin their business in Korea soon, as Korea will open their insurance market to them. While sprinkler system plays very important role in total fire protection system, Korean sprinkler system design has not been studied in depth. Thus, it is not easy to convince the performance of Korean sprinkler system and compare it to NFPA 13, Standard for the Installation of Sprinkler System. Design guideline from both system will be listed and compared in detail. Fire water demand from both system will be reviewed to evaluate its adequacy. Water spray density and actuation time will be estimated, too.

  • PDF

공연장 무대부 화재 시 자연배출구 및 방화막 영향 검토를 위한 축소모형 실험 (Reduced-scale Model Experiment for Examination of Natural Vent and Fire Curtain Effects in Fire of Theater Stage)

  • 백선아;양지현;정찬석;이치영;김동균
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.41-49
    • /
    • 2019
  • 본 연구에서는 실존하는 공연장을 대상으로 1/14 비율로 축소하여 제작한 모형을 이용하여 공연장 무대부 화재 시 자연배출구 및 방화막 영향을 검토하였다. 자연배출구가 개방되고 방화막이 미설치된 경우에 무대부 온도가 낮은 것으로 나타난 반면, 객석부 온도의 경우 자연배출구가 개방되고 방화막이 설치된 경우에 낮은 것으로 측정되었다. 한편, 객석부 프로시니엄 개구부에 근접한 위치에서의 온도 상승 시점 분석을 통해 자연배출구 개방이 무대부에서 객석부로의 연기 유출 시작 시점을 지연시키고 객석부 온도 상승을 억제할 가능성이 있음을 확인하였다. 본 실험 조건에서 방화막 설치 여부는 자연배출구를 통한 유출 유동의 속도 및 질량 유량에 큰 영향을 미치지 않았는데, 이는 무대부에 존재하는 개구부 때문으로 판단된다. 본 실험 결과는 실제 공연장 화재 시 자연배출구 및 방화막 영향 평가를 위한 기초 데이터로 활용 가능할 뿐 아니라 전산시뮬레이션의 신뢰성 검증을 위한 자료로 이용될 수 있을 것으로 판단된다.

거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구 (A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room )

  • 이생곤;민세홍
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.439-450
    • /
    • 2023
  • 연구목적: 국내에서 소방점검을 시행시 바닥면적 400m2 미만일 경우 공기유입구와 배출구간의 직선거리 5m이상 하라는 소방법규에 위반되는 대상물들이 있으며 이러한 이유를 분석하고 관련 소방법규의 필요성을 뒷받침 하기 위해 모형실험연구를 시행한 논문이다. 연구방법: 국내소방 대상물을 조사확인 하였고, 국내 및 해외논문 및 정책, 법규를 문헌고찰 하였으며, 400m2 미만의 거실에서 공기 유입구와 배출구간의 직선거리 5m 이하와 5m이상인 공간을 선정하여 모형실험 을 통해 분석하였다. 연구결과: 국내 소방법규(NFPC-화재안전성능기준)를 고찰 하였을 때 바닥면적 400m2 미만일 경우 공기유입구와 배출구 간의 5m 이상으로 이격 거리가 규정되어있지 만 실제 조사해 본 결과 이격 거리를 지키지 못하는 소방대상물이 있는 것으로 확인되었다. 또한 5m 이상의 직선거리에 대한 해외 소 방법규에 대한 논문 고찰을 해봤을 때 공기유입구와 배출구간의 직선거리에 대한 규정이 없는 것으로 나타났지만, 모형실험 한 결과 공기유입 구와 배출구간의 직선거리가 5m이상 일 때가 5m미만 일 때보다 배출속도가 우수한 것으로 나타났다. 결론: 본 연구에서는 공기유입구와 배출구간의 직선거리에 대한 제연설비 성능비교로 해외 소방법규 를 조사하였을 때 직선거리에 대한 강제규정이 없지만 국내 소방법규(NFPC_화재안전성능 기준)에 서는 5m이상을 해야 한다는 법규를 뒷받침하는 근거를 마련하는 논문이다. 앞으로 설계 단계에서 이를 반영하여 소방 감리의 책임과 부담을 줄여줄 수 있는 토대가 마련되길 바란다.

건축 마감재의 화재안전기준 비교분석을 통한 한옥 부재의 난연성능 평가기준 연구 (A Study on Evaluation Methods for the Fire-retardant Performance of Hanok Components)

  • 곽지현;최정민;구재현
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.1-7
    • /
    • 2011
  • 본 연구에서는 한옥의 주요 부재에 대한 난연기술 개발 및 성능향상을 위한 기초단계로 미국, 일본, 유럽 및 국내의 건축물 마감재의 난연성능 관련 법규 및 시험기준 등을 비교 분석하여 각 부재의 난연성능 평가기준을 제시하고자 하였다. 미국의 경우 최근 통합되어 사용 중인 IBC(International Building Code) 및 NFPA(National Fire Protection Association) Code가 적용되고 있으며, 평가항목으로는 바닥재에 대해서는 임계열유속을, 천장 및 벽체에 대해서는 화염확산지수 및 연기발생량을 적용하고 있다. 유럽의 경우 통합된 Euroclass가 적용되고 있는데 바닥재와 비바닥재를 구분하여 난연성능 등급별로 불연성시험, 화염 전파성시험, 소규모실물화재시험, 발열량시험 등을 평가항목으로 두고 있다. 일본의 경우는 우리나라의 체계와 유사하였는데, 이들 각국의 기준을 비교분석하여 목조물인 한옥 부재에 적용할 수 있는 정량적인 난연성능 평가방법에 대해 고찰해 보았다.

사양위주 스프링클러설비 설계의 압력과 유량의 문제점에 대한 고찰 (A Study on the Problem of Pressure and Flow Rate by Prescriptive Code Based Design of Fire Sprinkler System)

  • 정기신;김위경
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.14-19
    • /
    • 2013
  • 스프링클러설비의 화재안전기준인 NFSC103은 설계면적 내의 모든 헤드로부터 방출압 1 bar이상과 방출량 80 lpm 이상을 최소기준으로 규정하고 있다. NFSC103은 또한 설치장소의 용도에 따라 설계면적에서 작동하는 헤드의 수를 10개, 20개, 30개로 규정하고 각 헤드별 유량을 80 lpm으로 하여 총유량을 800 lpm, 1,600 lpm, 2,400 lpm으로 규정하고 있다. 이 규정대로 스프링클러 설비를 설계하면 약 50 %의 스프링클러헤드에서 유량과 압력이 최소기준보다 부족하게 된다. 이는 스프링클러의 목적인 초기화재 대응에 실패를 가져오는 심각한 결과를 초래할 수 있다. 이와 같은 문제점을 해결하기 위해서는 성능위주 설계인 수리계산방법에 의해 모든 스프링클러설계가 이루어지는 것이 바람직하다.

소방 배관 동파방지용 열선의 위치 선정을 위한 비정상 열전달 수치해석 (Numerical Analysis of Unsteady Heat Transfer for the Location Selection of Anti-freeze for the Fire Protection Piping with Electrical Heat Trace)

  • 최명영;이동욱;최형권
    • 한국화재소방학회논문지
    • /
    • 제28권1호
    • /
    • pp.52-57
    • /
    • 2014
  • 본 논문에서는 에너지방정식과 비정상 비압축성 Navier-Stokes 방적식을 사용하여 동절기 소방배관의 동파방지를 위한 최적의 열선위치를 확인하였다. 물의 자연대류와 소방 배관의 전도 열방정식이 결합된 복합열전달을 해석하였다. 혼합 열전달 배관 내 물의 비정상적인 유동과 온도분포를 확인하기 위하여 SIMPLE 형태의 알고리즘을 기반으로 한 상용코드(ANSYS-FLUENT)가 사용되었다. 수치해석을 수행하여 등온선과 벡터장을 살펴보았다. 물의 열팽창계수를 일정하다고 가정할 때 소방 배관 단면의 하부에 열선을 설치하는 것이 다른 위치에 설치하는 것보다 시간에 따른 물의 최저온도가 가장 높아서 동파방지에 가장 효과적인 것을 확인할 수 있었다.