• Title/Summary/Keyword: National Disaster

Search Result 3,014, Processing Time 0.033 seconds

Natural Background and Enrichment Characteristics of the Stream Sediments from the Hamyang-Sancheong Area (함양-산청지역 하상퇴적물의 자연배경치 및 부화특성)

  • Park, Young-Seog;Park, Dae-Woo;Kim, Jong-Kyun
    • Economic and Environmental Geology
    • /
    • v.42 no.3
    • /
    • pp.195-206
    • /
    • 2009
  • We investigated natural background and enrichment characteristics and predicted geochemical disaster for stream sediments in the Hamyang-Sancheong area. Stream sediments samples were collected 95 ea in study area. The stream sediments were well known that had not possibility of contamination effect and represented drainage basins. We got the major and hazardous elements concentrations by XRF, ICP-AES and NAA analysis methods. Acid decomposition for the ICP-AES has been used $HClO_4$ and HF with $200^{\circ}C$ heating at 1st and after that $HClO_4$ HF and HCl with $200^{\circ}C$ heating at 2nd stage. We could know the characteristics that concentration of Cu and Co decreased when concentration of $SiO_2$ increased in correlation analysis. The enrichment factor of the stream sediments was below 2 in study area. This result indicated that study area belonged to moderate enrichment. The stream sediments of Hamyang area were enriched in order of Pb>Th>Cr>V>Co>Cu and those of Sancheong area were enriched in order of Pb>Th>Cr>Co>V>Cu. The enrichment factor(E.F.) of the Pb, Cr, Co and V was similar between Hamyang and Sancheong area. The enrichment factor of the Th was higher in Hamyang area and that of the Cu was higher in Sancheong area. The enrichment factor of the Pb was highly enriched in all study area than earth crust mean. But we could know that study area was not exposed to the pollution of the Pb through the tolerable level.

The Characteristics and Improvement Directions of Regional Climate Change Adaptation Policies in accordance with Damage Cases (지자체 기후변화 적응 대책 특성 및 개선 방향)

  • Ahn, Yoonjung;Kang, Youngeun;Park, Chang Sug;Kim, Ho Gul
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.4
    • /
    • pp.296-306
    • /
    • 2016
  • There is a growing interest in establishing a regional climate change adaptation policy as the climate change impact in the region and local scale increases. This study focused on the analysis of 32 regions on its characteristics of local climate change adaptation plans. First, statistic program R was used for conducting cluster analysis based on the frequency and budgets of adaptation plan. Further, we analyzed damage frequency from newspapers regarding climate change impacts in eight categories which were caused by extreme weather events on 2,565 cases for 24 years. Lastly, the characteristics of climate change adaptation plan was compared with damage frequency patterns for evaluating the adequacy of climate change adaptation plan on each cluster. Four different clusters were created by cluster analysis. Most clusters clearly have their own characteristics on certain sectors. There was a high frequency of damage in 'disaster' and 'health' sectors. Climate change adaptation plan and budget also invested a lot on those sectors. However, when comparing the relative rate among regional governments, there was a difference between types of damage and climate change adaptation plan. We assumed that the difference could come from that each region established their adaptation plans based on not only the frequency of damage, but vulnerability assessment, and expert opinions as well. The result of study could contribute to policy making of climate change adaptation plan.

Flame Retardant Property of PU by the Addition of Phosphorous Containing Polyurethane Oligomers (폴리우레탄을 인계화합물로 해중합한 올리고머의 난연성)

  • Jung, Sunyoung;Kang, Sungku;Cho, Ilsung;Koh, Sungho;Kim, Younhee;Chung, Yeongjin;Kim, Sangbum
    • Applied Chemistry for Engineering
    • /
    • v.18 no.4
    • /
    • pp.376-380
    • /
    • 2007
  • Used polyurethane (PU) was chemically degraded by the treatment with flame retardants such as tris(1,3-chloro-2-propyl) phosphate (TCPP), triethyl phosphate (TEP), and trimethyl phosphate (TMP). Analysis of FT-IR and P-NMR showed that the degraded products (DEP) contained oligourethanes. Rigid polyurethane foam was produced using the DEP as flame retardants. The flammability and thermal stability of recycled rigid polyurethane were investigated. The mechanical properties such as compressive strength of recycled polyurethane were also studied. The recycled polyurethane reduced flammability and enhanced thermal stability over intrinsic polyurethane. Mechanical strength of recycled polyurethane also shows as high as that of intrinsic polyurethane. In order to evaluate flame retardant properties of the recycled polyurethane foams with various amounts of DEP, heat release rate (HRR) of the foam was measured by cone calorimeter. Scanning electron micrograph of recycled PU showed a uniform cell morphology as a intrinsic PU.

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

A Study of the Velocity Distribution and Vorticity Measurement in the Pump Sump Using PIV (PIV를 이용한 흡수조 내 유속분포 및 와류강도 측정에 대한 연구)

  • Byeon, Hyun Hyuk;Kim, Seo Jun;Yoon, Byung Man
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.145-156
    • /
    • 2020
  • The climate change occurring all over the world increases the risk, specially in urban area, Accordingly, rainwater pumping station expansion is required than before. In order to increase the efficiency of the rainwater pumping station, the analysis of flow characteristics in the pump sump is needed for vortex control. Many efforts have been made to illuminate the vortex behavior using PIV, but any reliable results have not been obtained yet, because of the limitations in image capturing and dependency of measured velocity values on the interrogation area and time interval used for velocity calculation. In this study, therefore, experiments were carried out to find out the limitation of PIV and estimate the validation of the velocity values associated with the analysis parameters such as interrogation area, time interval, grid size. For the experimental condition used in this study, the limitation of PIV and the effects of parameters on the velocity estimation are presented.

Satisfaction with Health Care in North Korea: A Study of North Korean Refugees in China (중국내 북한이탈주민을 통해 본 북한의료이용 만족도)

  • Kim, Gae-Young;Chung Woo-Jin;Lee, Yun-Hwan;Park, Chong-Yon;Robinson W. Courtland;Lee, Myung-Ken;Lee, Og-Cheol;Burnham Gilbert M.
    • Health Policy and Management
    • /
    • v.16 no.4
    • /
    • pp.48-67
    • /
    • 2006
  • The aim of the study was to examine levels of satisfaction with health care in North Korea and to identify factors associated with it using a convenience sample of North Korean refugees in China. Data from the 2004 Survey of Health Seeking Behavior of North Korean Households conducted by the Center for Refugee and Disaster Response, Johns Hopkins Bloomberg School of Public Health were used. The study subjects were 273 North Korean refugees whose length of stay in China was less than 3 months. Factor analysis was used to extract factor dimensions from the 12 satisfaction items. Bivariate (t test and ANOVA) and multiple regression analyses were used in examining factors associated with satisfaction with health care use in North Korea Overall, satisfaction level was low ($2.36{\pm}0.36$, score range: 1-5). Of the three-factor dimensions, physician skills scored the highest $(2.93{\pm}0.36)$, followed by drug availability $(2.51{\pm}0.07)$ and general cleanliness $(1.66{\pm}0.55)$. In the multiple regression analysis, having a usual source of care was significantly associated with patient satisfaction. Respondents who identified primary care (section) doctors as their usual source of care tended to be less satisfied than those with the city or county hospital as their usual source of care. County residents tended to report a lower degree of satisfaction with general cleanliness than city residents. Among socioeconomic characteristics, the number of household assets positively predicted satisfaction with drug availability. North Korean residents appear to be dissatisfied with their medical care. It may reflect some inadequacies in the North's universal health care system to meet the healthcare needs of its people.

Effect of Gap grade on Shear Strength of sandy soil (갭 입도 변화에 따른 사질토의 지지력 향상 효과)

  • Kim, Kab-Boo;Moon, Jun-Ho;Gu, Kyo-Young;Chun, Young-Woo;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.319-324
    • /
    • 2016
  • Soils with various particle sizes generally show good shear strength. Some soils have a relatively strong resistance to shear failure in spite of narrow particle distribution, such as gap grading. Based on this example, it can be inferred that appropriate arrangements of particle size in soils might result in an increase in shear strength. This study investigates the strength variation of soils with respect to the particle size distribution. Gap, well, and uniform graded soils were prepared with a desired ratio, and a wide range of direct shear tests were done using the prepared samples. The test results show that there is a strong relationship between the particle size ratio and internal frictional angle. Gap graded soil has a greater frictional angle than a well-graded sample, even when specimens have the same maximum particle size, which is also the case for the uniform grade specimen. The results have potential for developing a methodology for stronger soils through a simple manipulation of particle size distribution.

Effects of NaCl/H3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (NaCl/H3PO4 내염화 처리가 라이오셀 섬유의 열 안정 및 내산화 특성에 미치는 영향)

  • Kim, Eun Ae;Bai, Byong Chol;Jeon, Young-Pyo;Lee, Chul Wee;Lee, Young-Seak;In, Se Jin;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.418-424
    • /
    • 2014
  • The improved thermal stability and anti-oxidation properties of Lyocell fiber were studied based on flame retardant treatment by using NaCl/$H_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various maxing ratio of NaCl and $H_3PO_4$ and the mechanism was proposed through experimental results of thermal stability anti-oxidation. The IPDT (integral procedural decomposition temperature), LOI (limited oxygen index) and $E_a$ (activation energy) increased 23, 30 and 24% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of Lyocell fiber were provided using NaCl/$H_3PO_4$ solution and the mechanism was also studied based on experimental results such as IDT (initial decomposition temperature), IPDT, LOI and $E_a$.

Corrosion Monitoring of Reinforcing Bars in Cement Mortar Exposed to Seawater Immersion-and-dry Cycles (해수침지-건조 환경에 노출된 모르타르속 철근의 부식속도 평가)

  • Kim, Je-kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.10-18
    • /
    • 2018
  • The primary purposes of this study are to understand a fundamental aspect of current uniformity around a reinforcing bar (rebar) in cement mortar, and to develop an accurate monitoring method in a wet-dry cycling process with the alternative current (AC) impedance method. Three cement mortar specimens with two embedded rebars were prepared in the laboratory. As a main variable, the distance between two rebars was designed to be 10, 20 and 30 mm with the same thickness of 20 mm. To simulate the corrosion of rebars in concrete structures in a marine environment, three cement mortar specimens were exposed to 15 wet-drying cycles (24-hour-immersion in seawater and 48-hour-drying in a room temperature) in the laboratory. It was observed that the potential level shifted to a noble value during corrosion potential monitoring, which is attributed to acceleration of dissolved oxygen diffusion at the drying process. AC impedance was measured in a frequency range from 100 kHz to 1 mHz on a wet-drying process. A theoretical model was proposed to explain the interface condition between the rebars and cement mortar by using the equivalent circuit consisting of a solution resistance, a charge transfer resistance and a CPE (constant phase element). It was observed that the diffusion impedance appeared in a low frequency range as corrosion of rebars progresses. At the drying stage of the wet-drying cycles, the currents line for monitoring tended to be non-uniform at the interface of rebar/mortar, being phase shift, ${\theta}$, close to $-45^{\circ}$.

Identifying Specifications of Flat Type Signboards Using a Stereo Camera (스테레오 카메라를 이용한 판류형 간판의 규격 판별)

  • Kwon, Sang Il;Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.1
    • /
    • pp.69-83
    • /
    • 2020
  • Signboards are standardized according to national legislation for the safety of pedestrians and disaster prevention in urban areas. Signboards should be installed according to the standard. However, it is not easy to manage the signboards systematically due to the number of signboards that have been installed for a long time and frequently changing stores. In this study, we proposed a methodology for distinguishing signboards that deviated from the standard. To this end, the signboard was photographed using a stereo camera, and then the three-dimensional coordinates of the signboard were determined from the signboard image to calculate the signboard's horizontal and vertical dimensions to determine the signboard's specifications. In order to determine the interior and relative orientation parameters of the stereo camera, an outdoor three-dimensional building was used as the test field. Then, the image coordinates of four vertices of the signboard were extracted from the signboard image taken from about 15m ~ 22m distance using deep learning. After determining the signboard's three-dimensional coordinates by using the interior and relative orientation parameters of the stereo camera and the image coordinates of the four vertices of the signboard, the horizontal and vertical sizes of the signboard were calculated, resulting in an error of about 2.7cm on average. The specifications for the ten flat-type signboards showed that all of the horizontal sizes were compliant with the specifications, but the vertical sizes exceeded about 36.5cm on average. Through this, it was found that maintenance of flat-type signboards is needed overall.