• 제목/요약/키워드: National College of Fire

검색결과 297건 처리시간 0.03초

A Study on the Policy Tasks for the Development of National Fire Service - Redesigning Institutional and Organizational Improvement for the Establishment of the National Fire Service Agency - (한국소방발전을 위한 정책과제 연구 - 소방청 신설에 대응하는 제도·조직개선 구상 -)

  • Choi, Byoung-Hahk;Kim, Hak-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • 제6권1호
    • /
    • pp.185-197
    • /
    • 2002
  • Today, the basic problem of functional safe management of Korean Disaster Control system was separately administrated 33 acts that are relating to safe management in 13 ministries. Because of the facts that the fire service is not provided practically, the control system and risk management for safe administration are not operated, the information can not be shared with each other, and the various laws have the lacks of linkage, the National Safe System was appeared unsteady. The roles and functions of fire service have started with restriction to operate structurally and institutionally, which operational structure of fire service is becoming weak. As a result, the federal and local fire organizations have not reached yet to the institutionalization and the local fire service agencies have bias with the task regarding the fire service because of the relation between organizational structure and the local fire agency. With the enforcement of the federal and local fire system, professionality and autonomy for making policy, and dealing with changes of fire service positively, the national fire service on the policy performance can be established. Promotion of research and development and education training to strengthen innovation in technology and competition in fire industry will contribute to the firmly establishment of control system to prevent from fire, flood, terror and national disaster. This article proposed that (a) the established law and administration, agency are required efforts to effectively operate fire service system; (b) the national fire service agency, national college of fire, national institute of science fire, and national fire service hospital should be early established to make firmly policy to operate effectively and practically. These kinds of innovational acts are known the best ways of operating solid policy of national fire service system.

  • PDF

An Experimental Study on the Development of Fire-retardant Treated Wood for Construction (건축용 난연 목재 개발에 대한 실험 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Jo, Jeong Min;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • 제32권5호
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.

Survey on the Utilization of Fire-Wood Boiler using Woody Biomass in Gangwon Province

  • Cha, Du-Song;Oh, Jae-Heun;Yi, Jae-Seon;Bae, Young-Soo
    • Journal of Forest and Environmental Science
    • /
    • 제23권2호
    • /
    • pp.79-85
    • /
    • 2007
  • This survey was carried out to investigate the utilization situation of fire-wood boiler by the questionnaire and personal interview on rural and mountain households of Gangwon province from 1998 to 2005. The questionnaire include 7 questions on installation, 7 questions on fuel, 3 questions on use, and 3 questions on improvement. Each question was analyzed by percentage to investigate the use situation. This survey indicated that the general problems in use of fire-wood boiler are fuel purchase, collection and transportation, that the development of the household heating boiler using wood-based forming fuel which is cheap, small volume, easy handling, convenient purchase and high heat efficiency could be an alternative to improve the problems and that the continuous expansion of the supply of fire-wood boiler can prevent the devastation of forest through the regulation of imprudent fuel supply. Although the financial aid plan on the installation of fire-wood boiler is in active, many petty households in rural and mountain areas lose a chance to install the fire-wood boiler due to the unsatisfactory information. Thus, it will be desirable for municipal government to prepare the information plan to offer the equal chance and condition to all households in rural and mountain areas and to increase the financial aid for the continuous supply of fire-wood boiler.

  • PDF

Evaluation of Fire Characteristics for Particle-board with Exfoliated Graphite Nanoplatelets Added (탄소재료의 적용 방법에 따른 파티클 보드의 연소 특성)

  • Seo, Hyun Jeong;Jo, Jeong Min;Hwang, Wuk;Lee, Min Chul
    • Journal of the Korean Society of Combustion
    • /
    • 제22권4호
    • /
    • pp.1-8
    • /
    • 2017
  • This study was conducted to evaluate the fire retardant performance of exfoliated graphite nanoplatelets (xGnP) applied for particleboard. This work measured heat release rate(HRR), total heat release(THR) and smoke production rate(SPR) of xGnP added particleboard, using cone calorimeter to assess its fire characteristics according to the KS F ISO 5660-1 standard code. Heat release rates of all specimens treated by xGnP were less than the $200kW/m^2$ for a total experiment period of five minutes. Heat release rates of the specimens coated with xGnP were lower than those of the specimens made by mixing wood particles with xGnP directly. Meanwhile, the total heat release rates of xGnP coated specimen maintained quite lower level than the uncoated so the xGnP coating were effective in improving the fire retardant performance of particleboard. However, the smoke emission peaking problem at the initial combustion period, which was caused by adding base coating materials, should be resolved for further satisfaction as a fire retardant materials.

Combustion Characteristics of Fire Retardants Treated Domestic Wood (난연처리 국산 침엽수재의 연소특성 분석)

  • Seo, Hyun Jeong;Hwang, Wuk;Lee, Min Chul
    • Journal of the Korean Society of Combustion
    • /
    • 제22권2호
    • /
    • pp.9-18
    • /
    • 2017
  • In this study, we measured that fire characteristics of four wood species using indoor finish materials. Wooden specimens were treated with fire retardant chemicals such as diammonium phosphate and potassium carbonate. The wooden specimens are Larix kaempferi, Pinus koraiensis, Cryptomeria japonica, and Chamaecyparis obtusa, which are used for indoor finish. The heat release rate (HRR) values of fire retardant treated woods were confirmed lower than that of untreated woods. For specific details, the HRR values of vacuum impregnated specimens for Pinus koraiensis and Cryptomeria japonica were measured lower than coatings. However, those of Larix kaempferi and Chamaecyparis obtusa showed the opposite effect to it. Total heat release rate values of all wooden specimens, vacuum impregnated were lower than coated specimens.

Evaluation of Fire Resistance Using Mechanical Properties at High Temperature for Steel Column Made of Rolled Steels (SS 400) (구조용 압연강(SS 400)의 고온 기계적 특성을 이용한 기둥부재의 내화성능 평가)

  • Kwon, In-Kyu;Shin, Soon-Gi
    • Korean Journal of Metals and Materials
    • /
    • 제49권9호
    • /
    • pp.671-677
    • /
    • 2011
  • Steel columns used in steel buildings are inclined to lose their strength when exposed to severe fire conditions, so fire resistance is required in most countries to protect against loss of life and building collapses. In Korea, the fire resistance of columns can be obtained by the fire test defined in KS F 2257-1, 7. The fire resistance of a steel column should be evaluated in terms of the column's conditions, such as various section types (H-section, hollow-section), the column's length and boundary conditions, and whether it is fixed or hinged. However, fire testing of steel columns is usually conducted on one standard-sized H-section over 3,000 mm, and the result is used as the column's fire resistance. This is not a reasonable way to ensure that a building can withstand fire conditions. In this study, to evaluate the possibility of calculating the fire resistance of steel columns with material properties of high tensile strength of SS 400, both load-bearing fire tests and calculation of steel temperatures were carried out. The results of temperature calculation were very similar to those obtained by fire test.

Improvement of Performance based wooden building National Fire Safety Codes (성능에 기반을 둔 목조건축물 화재안전기준 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • 제18권2호
    • /
    • pp.83-92
    • /
    • 2016
  • Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.

Effects of Forest Fire on the Forest Vegetation and Soil (II) (황폐산지(荒廢山地)에서의 산불이 삼림식생(森林植生) 및 토양(土壤)에 미치는 영향(影響)에 관한 연구(研究)(II))

  • Woo, Bo Myeong;Kwon, Tae Ho;Ma, Ho Seop;Lee, Heon Ho;Lee, Jong Hak
    • Journal of Korean Society of Forest Science
    • /
    • 제68권1호
    • /
    • pp.37-45
    • /
    • 1985
  • The second year's results of surface fire effects on forest vegetation and soil properties and fire tolerance of various tree species were investigated in Mt. Gwanak, Kyunggi-do, successively after the study of the first year's effect in the same place. Soil moisture contents, organic matters, and most of soil nutrients including exchangeable bases had increased just after fire and went down to become somewhat constant. Available phosphorous at fired area decreased until it became similar to that at unfired area, while pH of subsoil was continuously increasing from just after fire till after 1 year. For Lespedeza and Weigela species, fire tolerance of tree crown was the lowest but reproductive capacity was the highest. And both of them were high for Rhododendron species. More exact classification into Increasers, Decreasers, Invaders and Neutral species was possible in the second year's study. According to comparison of similarities, it was found that the vegetational structure at fired area is slowly restoring to original state as time goes.

  • PDF

Study on the Reliability Analysis of Wood Floor System Exposed to Fire (화염에 노출된 목재 마루 시스템의 신뢰성 해석에 관한 연구)

  • Kim, Gwang-Chul;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권5호
    • /
    • pp.66-74
    • /
    • 2004
  • Fire performance is the important criterion for evaluating of safety of wood structures which exposed to the standard fire condition. Endurance time and time-to-failure are used as the criteria for fire performance in many countries. Reliability analysis about wood floor system which exposed to fire was carried out as preliminary research for reliability-based design on fire. Analyses were conducted by two methods, numerical analysis method and deterministic method.. They didn't show the difference between two methods. The reliability of floor exposed to fire showed strong dependence on the coefficient of variation of member and did not be influenced by the strength or load of member.

Fireproof Performance Study of ICT Fire Damper by Using Experimentalmethode (실험적 방법에 의한 ICT 파이어 댐퍼의 내화성능연구)

  • Hur, Nam-Soo;Kim, In-Whan;Jang, Sung Cheol;Kim, Jae-Woong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제13권5호
    • /
    • pp.82-89
    • /
    • 2014
  • In this paper, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.