• Title/Summary/Keyword: National Artifact

Search Result 284, Processing Time 0.026 seconds

Chemical Constituents of Lathyrus davidii

  • Park, Su-Yeon;Kim, Ju-Sun;Lee, So-Young;Bae, Ki-Hwan;Kang, Sam-Sik
    • Natural Product Sciences
    • /
    • v.14 no.4
    • /
    • pp.281-288
    • /
    • 2008
  • From the MeOH extract of the whole plants of Lathyrus davidii (Fabaceae), thirteen constituents were isolated and identified as the flavonoids astragalin, isoquercitrin, nicotiflorin, and rutin, as the saponins soyasapogenol B 3-O-${\beta}$-D-glucuronopyranoside, azukisaponins II and V, soyasaponins II and V and as 4-O-${\beta}$-Dglucopyranosyl syringic acid, uracil and n-hexacosanol. Five saponins and 4-O-${\beta}$-D-glucopyranosyl syringic acid were isolated from the BuOH fraction as their methyl esters. Ombuoside (rutin 7,4'-di-O-methyl ether) was also isolated from the methylated BuOH-soluble fraction. However, no ombuoside was detected in the HPLC analysis of the nonmethylated BuOH fraction. Therefore, ombuoside is an artifact derived from methylation of rutin. All of these compounds were isolated for the first time from this plant.

Optimizing Imaging Conditions in Digital Tomosynthesis for Image-Guided Radiation Therapy (영상유도 방사선 치료를 위한 디지털 단층영상합성법의 촬영조건 최적화에 관한 연구)

  • Youn, Han-Bean;Kim, Jin-Sung;Cho, Min-Kook;Jang, Sun-Young;Song, William Y.;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.281-290
    • /
    • 2010
  • Cone-beam digital tomosynthesis (CBDT) has greatly been paid attention in the image-guided radiation therapy because of its attractive advantages such as low patient dose and less motion artifact. Image quality of tomograms is, however, dependent on the imaging conditions such as the scan angle (${\beta}_{scan}$) and the number of projection views. In this paper, we describe the principle of CBDT based on filtered-backprojection technique and investigate the optimization of imaging conditions. As a system performance, we have defined the figure-of-merit with a combination of signal difference-to-noise ratio, artifact spread function and floating-point operations which determine the computational load of image reconstruction procedures. From the measurements of disc phantom, which mimics an impulse signal and thus their analyses, it is concluded that the image quality of tomograms obtained from CBDT is improved as the scan angle is wider than 60 degrees with a larger step scan angle (${\Delta}{\beta}$). As a rule of thumb, the system performance is dependent on $\sqrt{{\Delta}{\beta}}{\times}{\beta}^{2.5}_{scan}$. If the exact weighting factors could be assigned to each image-quality metric, we would find the better quantitative imaging conditions.

Study on the Damage Mechanism by Salt of White Porcelain Figurine in Underglaze Iron (백자 철화 인물형 명기의 염 손상 메커니즘 연구)

  • Lee, Sun Myung;Jin, Hong Ju;Yun, Ji Hyeon;Kwon, Oh Young
    • Journal of Conservation Science
    • /
    • v.36 no.5
    • /
    • pp.368-382
    • /
    • 2020
  • It was confirmed that a white porcelain figurine in underglaze iron was damaged after exhibition. This study analyzes the current state of salt damage on the artifact and identifies the factors contributing to its deterioration by examining the material characteristics of the artifact and exhibition environment. The analysis will thus assist in preparing a conservation scheme for artifacts. The crystallized carbonate on the surface of the white porcelain figurine is a water-soluble alkali salt with high hygroscopicity and high solubility in water. This solubility increases as the temperature increases. The figurine was low-fired at approximately 1000℃. A lead glaze was applied, and thin cracks were formed on the glazed surface, indicating poor surface properties. Our analysis suggested that the showcase used in the exhibition likely created a moist environment resulting from condensation, as it was exposed to high temperature and relative humidity, particularly in comparison to the exhibition room where the temperature was regulated using an air conditioner. In addition, the artifacts in the showcase were exposed to sudden changes in temperature and relative humidity as the air conditioner was repeatedly turned on and off. Therefore, it can be deduced that the soluble salt remaining on the white porcelain figurine moved toward the surface of the relatively weak glaze as a result of the temperature, and the crystallized salt exacerbated surface damage as the moisture evaporated in a dry environment.

Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality (소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰)

  • Nim Lee;Hyun-Hae Cho;So Mi Lee;Sun Kyoung You
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.240-252
    • /
    • 2023
  • Purpose To assess the effect of deep learning image reconstruction (DLIR) for head CT in pediatric patients. Materials and Methods We collected 126 pediatric head CT images, which were reconstructed using filtered back projection, iterative reconstruction using adaptive statistical iterative reconstruction (ASiR)-V, and all three levels of DLIR (TrueFidelity; GE Healthcare). Each image set group was divided into four subgroups according to the patients' ages. Clinical and dose-related data were reviewed. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and qualitative parameters, including noise, gray matter-white matter (GM-WM) differentiation, sharpness, artifact, acceptability, and unfamiliar texture change were evaluated and compared. Results The SNR and CNR of each level in each age group increased among strength levels of DLIR. High-level DLIR showed a significantly improved SNR and CNR (p < 0.05). Sequential reduction of noise, improvement of GM-WM differentiation, and improvement of sharpness was noted among strength levels of DLIR. Those of high-level DLIR showed a similar value as that with ASiR-V. Artifact and acceptability did not show a significant difference among the adapted levels of DLIR. Conclusion Adaptation of high-level DLIR for the pediatric head CT can significantly reduce image noise. Modification is needed while processing artifacts.

Study on Manufacturing Techniques and Conservation for Earthenware Horn Cups with a Horse Head Decoration(Treasure) (보물 도기 말머리장식 뿔잔의 제작 기법 연구와 보존처리)

  • KWON, Ohyoung;HAM, Chulhee;YU, Jia;KIM, Hanseul;PARK, Changyuel
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.51-61
    • /
    • 2022
  • Earthenware horn cups with horse head decorations were excavated from Tomb No. 7 of Bokcheon-dong, Dongraegu, Busan Metropolitan City. Made of earth in the shape of a horn, these cups are considered to have been used to drink alcohol or beverage. Large numbers of earthenware horn cups of various shapes were excavated from tombs located in the old territories of Silla and Gaya. A pair of earthenware horn cups were excavated from Tomb No. 7, and the two cups are almost identical in overall shapes and manufacturing techniques despite different sizes. Conservation treatment was carried out for the bigger one of the two horn cups this time. There are two cracks toward the horse head decorations around the mouth with missing parts observed. The chest of the horse touches the ground with one side decorating the horse head and the other side facing the conical mouth of the horn cup. It is in the U shape, striking a balance based on two legs attached behind. The surface of the horn cup was made with a potter's wheel, and the connection to the horse head has traces of cutting and trimming. The horse head is expressed realistically with its features including the ears, eyes, nose, and mouth well apprehended and its color is grey This study intended to investigate manufacturing techniques of the artifact by examining its internal structure through the condition survey in a non-destructive way. CT imaging was used to figure out its manufacturing techniques and to diagnose its condition, and accordingly the scientific conservation treatment was conducted to stabilize the artifact. The precise diagnosis on conservation condition found that there are two chips in the spout with their cracks extended. One of the chips is connected with separation added to the crack. The material which has been used for connection in the past was collected for the infrared spectroscopic analysis, which was identified to be nitrocellulose resin for the connection. Therefore, this conservation treatment focused on removing the old material and preventing the spread of cracks. Before conservation treatment, the condition survey and scientific examination for the artifact were carried out to secure data about the earthenware horn cup with horse head decorations(Treasure). Based on them, effective plans for its conservation treatment was sought for and then existing adhesive was safely removed, and restoration material was selected to take into account its reversibility. In addition, the conservation treatment according to optimal methodologies was conducted through the consultation meeting with experts.

A Color Correction Method for High-Dynamic-Range Images Based on Human Visual Perception (인간 시각 인지에 기반을 둔 높은 동적폭을 갖는 영상 보정 방법)

  • Choi, Ho-Hyoung;Song, Jae-Wook;Jung, Na-Ra;Kang, Hyun-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.9
    • /
    • pp.1027-1038
    • /
    • 2015
  • For last several decades, the color correction methods have been proposed for HDR(high dynamic range) images. However, color distortion problems take place after correcting the colors such as halos, dominant color as well known. Accordingly, this article presents a novel approach in which the method consists of tone-mapping method and cone response function. In the proposed method, the tone mapping method is used to improve the contrast in the given HDR image based on chromatic and achromatic based on the CIEXYZ tristimulus value, expressed in c/m2. The cone response function is used to deal with mismatch between corrected image and displayed image as well as to estimate various human visual effects based on the CMCAT2000 color appearance model. The experimental results show that the proposed method yields better performance of color correction over the conventional method in subjective and quantitative quality, and color reproduction.

False-positive I-131 Scan by Contaminated Muffler in a Patient with Thyroid Carcinoma (갑상선암 환자에서 방사성 옥소로 오염된 목도리에 의한 위양성 소견)

  • Seo, Han-Kyung;Kim, Min-Woo;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.51-52
    • /
    • 2006
  • A 39-year-old female patient who had undergone a total thyroidectomy for a papillary thyroid carcinoma underwent a whole body scan with I-131. The I-131 scan was performed 72 hours after administering 185 MBq (5 mCi) of an I-131 solution. The anterior image of the head, neck, and upper chest showed multiple areas of increased uptake in the mediastinal area considering of functional metastasis. However, radioactivity was not evident in the image taken after removing her clothes and muffler. The image obtained after placing the muffler on the pallet showed that the radioactivity was still present. It is well known that artifacts on an I-131 scan can be produced by styling hair sputum, drooling during sleep, chewing gum, and paper or a cloth handkerchief that is contaminated with the radioactive iodine from either perspiration or saliva. This activity might be mistaken for a functional metastasis. Therefore, it is essential that an image be obtained after removing the patient's clothes. In this study, artifacts due to a contaminated muffler on the I-131 scan were found. These mimicked a functional metastasis of the mediastinal area in a patient with a papillary thyroid carcinoma.

CT characteristics of normal canine pulmonary arteries and evaluation of optimal contrast delivery methods in CT pulmonary angiography

  • Jung, Joohyun;Chang, Jinhwa;Yoon, Junghee;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.247-254
    • /
    • 2007
  • This study was performed to identify the normal anatomic orientation of pulmonary arteries and to obtain the normal baseline parameters and the optimal contrast material delivery methods of computed tomographic pulmonary angiography (CTPA) on normal beagle dogs. Based on the contrast injection flow rate, the contrast volume, and the administration methods, the experimental groups were divided into 4 groups such as group 1 : 2 ml/s, 3 ml/kg, and monophasic administration; group 2 : 5 ml/s, 3 ml/kg, and monophasic administration; group 3 : 5 ml/s, 4 ml/kg, and monophasic administration; group 4 : 5 ml/s and 2 ml/kg in first phase, 0.3 ml/s and 2 ml/kg in second phase, as biphasic administration. Normal anatomic orientation of pulmonary arteries in CTPA was evaluated through reformatted and 3D images after retro-reconstruction. Normal parameters for great arteries and peripheral pulmonary arteries were obtained on the factor of basement hounsfield unit (HU) values, contrast enhanced HU values, delay time, and peak time. And the optimal contrast delivery methods were evaluated on the factor of contrast enhanced HU values, image quality, and artifact. The monophasic administration with 5 ml/s contrast injection flow rate and 3 ml/kg contrast volume was optimal in canine CTPA.

Achiral and Chiral Determination of Benzophenanthridine Alkaloids from Methanol Extracts of Hylomecon Species by High Performance Liquid Chromatography

  • Kang, Jong-Seong;Long, Pham-Hoai;Lim, Hwan-Mi;Kim, Young-Ho;Gottfried-Blaschke
    • Archives of Pharmacal Research
    • /
    • v.26 no.2
    • /
    • pp.114-119
    • /
    • 2003
  • A high performance liquid chromatographic (HPLC) method was developed for the qualitative and quantitative determination of benzophenanthridine alkaloids from the methanol extracts of Hylomecon hylomeconoides and H. vernale (Papaveraceae). Achiral and chiral methods were adapted for the separation of 6-methoxydihydrosanguinarine (1), 6-acetonyldihydrosanguinarine (2) and dihydrosanguinarine (3). The achiral reversed phase HPLC method made it possible the simultaneous separation and determination of 1, 2 and 3 within 20 min on ODS column using acetonitrile-phosphate buffer (50 mM, pH 7.0) (50 : 50, v/v). The separation and determination of 1 and 2 enantiomers was available using chiral columns. The same amount of (+) and (-)-enantiomers of 1 was found from the methanol extract of specimen, indicated that 1 could be the artifact produced by the reaction of sanguinarine with methanol. H. hylomeconoides showed higher level of 1 and 3 in compared with H. vernale, especially in root samples permitting the possibility of chemical discrimination between two species.

Conservation of the Bronze Incense Burner Inlaid with Gold and Silver (동제금은입사향로(銅製金銀入絲香爐)의 보존처리(保存處理))

  • Nam, Seonghun;Yu, Heisun
    • Conservation Science in Museum
    • /
    • v.6
    • /
    • pp.31-37
    • /
    • 2005
  • The copper incense burner inlaid with gold and silver and purchased by the National Museum of Korea in 2002 was to be corroded severely throughout the surface. It was difficult to recognize the part with silver inlaying. Using the abrasive method with alumina, however, its splendid inlaying patterns were restored. Prior to applying the abrasive method, the quality was examined, and a material that could help bring out the patterns without causing too much damage to the artifact, selected. The overall condition of the incense burner was also checked through X-ray equipment to know the condition of the gold and silver inlaying, and by x-ray fluorescence spectroscopy to confirm the composition of the incense burner and gold and silver inlaying. The result of this process is expected to serve as valuable data in future research on incense burners inlaid with gold and silver.