• Title/Summary/Keyword: Nano-tip

Search Result 188, Processing Time 0.033 seconds

Numerical Analysis of Emission-type THz NSOM (Emission-type THz NSOM 에 대한 수치해석)

  • Lee, Kyoun-Gin;Yun, Seok-Ho;Park, Hong-Kyu;Kim, Jeong-Hoi;Han, Hea-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.183-184
    • /
    • 2006
  • The simulation on the mechanism of terahertz NSOM(near-field scanning optical microscopy) have been investigated. Based on experimental results, we have demonstrated the antenna effects on the coupling between a metal tip and substrate for an emission-type terahertz NSOM. It has been found that the lateral resolution can be estimated by a simplified model using an infinitesimal dipole in the substrate.

  • PDF

Nanotribological characteristics of silicon surfaces modified by IBAD (IBAD로 표면개질된 실리콘표면의 나노 트라이볼로지적 특성)

  • 윤의성;박지현;양승호;공호성;장경영
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.127-134
    • /
    • 2001
  • Nano adhesion and friction between a Sj$_3$N$_4$ AFM tip and thin silver films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM(atomic force microscope) and LFM(lateral force microscope) modes in various ranges of normal load. Thin silver films deposited by IBAD (ion beam assisted deposition) on Si-wafer (100) and Si-wafer of different surface roughness were used. Results showed that nano adhesion and friction decreased as the surface roughness increased. When the Si surfaces were coated by pure silver, the adhesion and friction decreased. But the adhesion and friction were not affected by the thickness of IBAD silver coating. As the normal force increased, the adhesion forces of bare Si-wafer and IBAD silver coating film remained constant, but the friction forces increased linearly. Test results suggested that the friction was mainly governed by the adhesion as long as the normal load was low.

  • PDF

Nano Wear Behavior of a-C Films with Variation of Surface Roughness (표면거칠기의 변화에 따른 a-C 박막의 나노마멸 거동)

  • 채영훈;장영준;나종주;김석삼
    • Tribology and Lubricants
    • /
    • v.20 no.3
    • /
    • pp.125-131
    • /
    • 2004
  • Nano-wear behavior of amorphous carbon films was studied by Atomic Force Microscopy. The a-C films are deposited on Si(100) substrate by DC magnetron sputtering method. The influences of different surface roughness on the nano-wear are investigated. Nano-wear tests were carried out using a very sharp diamond coated tip. Its spring constant was 1.6 N/m and radius of curvature was 110 nm. Normal force used in the wear tests ranged 0 to 400 nN. It was found that surface depression occurred during scratching because of plastic deformation and abrasive wear (cutting St ploughing). Wear depth increased linearly with normal force. Changing the surface roughness variables according to the bias pulse control, the less surface roughness decreased the wear depth. The thickness did not affect the wear resistance.

Localized Oxidation of (100) Silicon Surface by Pulsed Electrochemical Processes Based on AFM (AFM 기반 Pulse 를 이용한 전기화학적 가공)

  • Lee, Jeong-Min;Kim, Sun-Ho;Park, Jeong-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1631-1636
    • /
    • 2010
  • In this study, we demonstrate a nano-scale lithograph obtained on localized (100) silicon (p-type) surface using by modified AFM (Atomic force microscope) apparatuses and by adopting controlling methods. AFM-based experimental apparatuses are connected to a customized pulse generator that supplies electricity between the conductive tip and the silicon surface, while maintaining a constant humidity throughout the lithography process. The pulse durations are controlled according to various experimental conditions. The electrochemical reaction induced by the pulses occurs in the gap between the conductive tip and silicon surface and result in the formation of nanoscale oxide particles. Oxide particles with various heights and widths can be created by AFM surface modification; the size of the oxide particle depends on the pulse durations and the applied electrical conditions under a humid environment.

Improve H2S Gas Sensing Characteristics through SnO2 Microparticle Surface Modification and Ti Nanoparticle Decoration using Tip Sonication (Tip sonication을 이용한 SnO2 마이크로 입자 표면 개질 및 Ti 나노 입자 장식을 통한 H2S 가스 감지 특성 향상)

  • Ji Yeon Shin;Chan Gyu Kim;Ji Myeong Park;Hong Nhung Le;Jeong Yun Hwang;Myung Sik Choi
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.105-111
    • /
    • 2024
  • In this study, the H2S gas sensing characteristics were evaluated using surface-modified SnO2 microparticles by tip sonication. The surface-modified SnO2 microparticles were synthesized using the following sequential process. First, bare SnO2 microparticles were synthesized via a hydrothermal method. Then, the surfaces of bare SnO2 microparticles were modified with Ti nanoparticles during tip sonication. The sensing characteristics of SnO2 microparticles modified with Ti were systematically investigated in the range of 100-300℃, compared with the bare SnO2 microparticles. In this study, we discuss in detail the improved H2S sensing characteristics of SnO2 microparticles via Ti nanoparticle modification.

Implementation of a Piezoresistive MEMS Cantilever for Nanoscale Force Measurement in Micro/Nano Robotic Applications

  • Kim, Deok-Ho;Kim, Byungkyu;Park, Jong-Oh
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.789-797
    • /
    • 2004
  • The nanoscale sensing and manipulation have become a challenging issue in micro/nano-robotic applications. In particular, a feedback sensor-based manipulation is necessary for realizing an efficient and reliable handling of particles under uncertain environment in a micro/nano scale. This paper presents a piezoresistive MEMS cantilever for nanoscale force measurement in micro robotics. A piezoresistive MEMS cantilever enables sensing of gripping and contact forces in nanonewton resolution by measuring changes in the stress-induced electrical resistances. The calibration of a piezoresistive MEMS cantilever is experimentally carried out. In addition, as part of the work on nanomanipulation with a piezoresistive MEMS cantilever, the analysis on the interaction forces between a tip and a material, and the associated manipulation strategies are investigated. Experiments and simulations show that a piezoresistive MEMS cantilever integrated into a micro robotic system can be effectively used in nanoscale force measurements and a sensor-based manipulation.

Mechano-Chemical Microfabrication Technology Based on Micro/Nano-Tribology : Development Process and Prospect (마이크로/나노 트라이볼로지 기반 기계-화학적 미세가공기술 : 발전과정 및 전망)

  • 성인하;김대은
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.274-279
    • /
    • 2002
  • In this paper, the development process of an unique and creative micro/nano-structure fabrication technique based on micro/nano-tribology are reviewed and discussed. The so-called Mechano-Chemical Process(MCP), which has been developed since 1995 by Tribology Research Laboratory at Yonsei University with the motivation to overcome the demerits of the conventional photolithographic techniques, is based on the fundamental understanding of the interaction between the tool tip and the workpiece surface. This process is a maskless process which offers tremendous flexibility in surface patterns that can be created on a workpiece surface without using any capital intensive equipment. It Is capable of fabricating the prototypes of micro/nano-components, micro- structured surface with various geometries, micro-molds for making polymer or metal parts, and micro-fluidic channels for lab-on-a- chip

  • PDF

An Experimental Study on the Nano-adhesion of Octadecyltrichlorosilane SAM on the Si Surface (OTS SAM의 미소 응착 특성에 관한 실험적 연구)

  • 윤의성;박지현;양승호;한흥구;공호성
    • Tribology and Lubricants
    • /
    • v.17 no.4
    • /
    • pp.276-282
    • /
    • 2001
  • Nano adhesion between SPM (scanning probe microscope) tips and 075 (octadecyltrichlorosilane) SAM (self-assembled monolayer) was experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM(atomic force microscope) and LFM(lateral force microscope) modes in various conditions of relative humidity. OTS SAM was formed on Si-wafer (100) surfaces, and Si$_3$N$_4$ tips of different radius of curvature were used. When the surface was hydrophobic, the adhesion and friction forces were found lower than those of bare Si-wafer. Results also showed that micro-adhesion force increased as the relative humidity and the tip radius of curvature increased. The main parameter for affecting the micro-adhesion was found absorbed humidity on the contact surface. These results were discussed with the JKR model and a capillary force caused by absorbed water.

Micro/Nano Adhesion and Friction Properties of Mixed Self-assembled Monolayer (혼합 자기 조립 단분자막의 마이크로/나노 응착 및 마찰 특성)

  • Yoon Eui-Sung;Oh Hyun-Jin;Han Hung-Gu;Kong Hosung;Jhang Kyung Young
    • Tribology and Lubricants
    • /
    • v.20 no.2
    • /
    • pp.51-57
    • /
    • 2004
  • Micro/nano adhesion and friction properties of mixed self-assembled monolayer (SAM) with different chain length for MEMS application were experimentally studied. Many kinds of SAM having different spacer chains(C6, C10 and C18) and their mixtures (1:1) were deposited onto Si-wafer, where the deposited SAM resulted in the hydrophobic nature. The adhesion and friction properties between tip and SAM surfaces under nano scale applied load were measured using an atomic force microscope (AFM) and under micro scale applied load were measured using ball-on-flat type micro-tribotester. Surface roughness and water contact angles were measured with SPM (scanning probe microscope) and contact anglemeter. Results showed that water contact angles of mixed SAMs were similar to those of pure SAMs. The morphology of coating surface was roughened as mixing of SAM. Nano adhesion and nano friction decreased as increasing of the spacer chain length and mixing of SAM. Micro friction was decreased as increasing of the spacer chain length, but micro friction of mixed SAM showed the value between pure SAMs. Nano adhesion and friction mechanism of mixed SAM was proposed in a view of stiffness of spacer chain modified chemically and topographically.

질소유량 변화와 고온 열처리에 의한 HfN 박막의 Nano-electrotribology 특성 연구

  • Park, Myeong-Jun;Kim, Seong-Jun;Kim, Su-In;Lee, Chang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.354.1-354.1
    • /
    • 2014
  • Hafnium nitride (HfN) 박막은 고온에서의 안정성과 낮은 비저항 그리고 산소확산에 대한 억제력을 가지고 있기 때문에 확산방지막으로 많은 연구가 진행 되고 있다. 현재까지 진행된 대부분의 연구는 HfN 박막의 전기적인 특성과 구조적인 특성에 대한 것이었고 다양한 연구 결과가 보고되었다. 하지만 기존의 연구들은 박막의 nano-electrotribology 특성에 대한 연구가 부족하여 박막 적층 공정시 요구되는 물성에 대한 연구가 절실하다. 따라서 본 연구에서는 HfN 박막의 증착조건 및 열처리조건에 따른 nano-electrotribology 특성 변화를 확인하고자 하였다. HfN박막은 rf magnetron sputter를 이용하여 Si 기판위에 Hf target으로 질소 유량을 변화시키며 증착하였고 가열로에서 $600^{\circ}C$$800^{\circ}C$로 20분간 열처리를 실시하였다. 열처리한 박막과 as-deposited 상태의 박막을 nano-indenter를 통하여 나노기계 전기적인 특성을 분석하였다. nano-indenter는 박막에 인가된 stress와 탄성계수(elastic modulus), 표면경도(surface hardness)와 같은 특성을 직접적인 tip 접촉을 통하여 in-situ로 분석할 수 있는 장비이다. 실험결과 HfN박막을 $600^{\circ}C$로 열처리 한 경우 표면경도가 16.20에서 18.59 GPa로 증가하였다. 표면경도의 증가는 열처리 시 박막내에 compressive stress가 생성되었기 때문이라고 생각된다. 그러나 $800^{\circ}C$로 열처리 한 경우 표면경도가 16.93 GPa로 감소하였는데 이는 표면균열 발생으로 인한 stress relaxation 때문인 것으로 생각된다. 증착 시 주입되는 질소의 유량과 열처리 온도는 HfN박막의 기계적 안정성에 영향을 미치는 중요한 요소임을 본 실험을 통해 확인하였다.

  • PDF