• 제목/요약/키워드: Nano-biosensor

검색결과 67건 처리시간 0.033초

High sensitivity biosensor for mycotoxin detection based on conducting polymer supported electrochemically polymerized biopolymers

  • Dhayal, Marshal;Park, Gye-Choon;Park, Kyung-Hee;Gu, Hal-Bon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.243.1-243.1
    • /
    • 2010
  • Devices based on nanomaterials platforms are emerging as a powerful tool for ultrasensitive sensors for the direct detection of biological and chemical species. In this talk, we will report the preparation and the full characterization of electrochemical polymerization of biopolymers platforms and nano-structure formation for electrochemical detection of enzymatic activity and toxic compound in electrolyte for biosensor applications. Formation of an electroactive polymer film of two different compounds has been quantified by observing new redox peak at higher potentials in cyclic voltammogram measurements. RCT value of at various biopolymer concentration based hybrid films has been obtained from electrochemical impedance spectroscopy analysis and possible mechanism for formation of complexes during electrochemical polymerization on conducting substrates has been investigated. Biosensors developed based on these hybrid biopolymers have very high sensitivity.

  • PDF

Diagnosis of Trace Toxic Uranium Ions in Organic Liver Cell

  • Ly, Suw Young;Pack, Eun Chul;Choi, Dal Woong
    • Toxicological Research
    • /
    • 제30권2호
    • /
    • pp.117-120
    • /
    • 2014
  • Uranium is toxic and radioactive traces of it can be found in natural water and soils. High concentrations of it in biological systems cause genetic disorders and diseases. For the in vivo diagnosis, micro and nano range detection limits are required. Here, an electrochemical assay for trace toxic uranium was searched using stripping voltammetry. Renewable and simplified graphite pencils electrode (PE) was used in a three-electrode cell system. Seawater was used instead of an electrolyte solution. This setup can yield good results and the detection limit was attained to be at $10{\mu}gL^{-1}$. The developed skill can be applied to organic liver cell.

Clinical In Vivo Bio Assay of Glucose in Human Skin by a Tattoo Film Carbon Nano Tube Sensor

  • Ly, Suw Young;Lee, Chang Hyun
    • 한국응용과학기술학회지
    • /
    • 제34권3호
    • /
    • pp.595-601
    • /
    • 2017
  • In vivo assay of glucose detection was described using a skin tattoo film electrode (STF), and the probe was made from carbon nano tube paste modification film paper. Here in the square-wave stripping anodic working range obtained of $20-100mgL^{-1}$ within an accumulation time of 0 seconds only in sea water electrolyte solutions of pH 7.0. The relative standard deviations of 50 mg glucose that were observed of 0.14 % (n=12), respectively, using optimum stripping accumulation of 30 sec, the low detection limit (S/N) was pegged at 15.8 mg/L. The developed results can be applied to the detect of in vivo skin sensing in real time. Which confirms the results are usable for in vitro or vivo diagnostic clinical analysis.

식품 유래 박테리아 현장검출용 바이오센서 (Biosensors for On-the-spot Detection of Bacteria from Foods)

  • 이원일;김보영;손영민;김아리;이내응
    • 센서학회지
    • /
    • 제25권5호
    • /
    • pp.354-364
    • /
    • 2016
  • Recently there have been extensive research activities on the development of on-the-spot detection technologies for bacteria from foods due to growing high demand for food safety. In particular, on-the-spot detection devices using biosensors with rapid, highly sensitive and multiplexed sensing capability are promising for portable or mobile applications. Firstly, issues related to on-the-spot bacteria detection are discussed. Then, detection methods for bacteria, types of biosensors depending on transducing principle and receptors, and platforms for integration of biosensors and signal readers are reviewed. Finally, prospects for development of on-the-spot detection devices are summarized.

Graphene Coated Optical Fiber SPR Biosensor

  • Kim, Jang Ah;Hwang, Taehyun;Dugasani, Sreekantha Reddy;Kulkarni, Atul;Park, Sung Ha;Kim, Taesung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.401-401
    • /
    • 2014
  • In this study, graphene, the most attractive material today, has been applied to the wavelength-modulated surface plasmon resonance (SPR) sensor. The optical fiber sensor technology is the most fascinating topic because of its several benefits. In addition to this, the SPR phenomenon enables the detection of biomaterials to be label-free, highly sensitive, and accurate. Therefore, the optical fiber SPR sensor has powerful advantages to detect biomaterials. Meanwhile, Graphene shows superior mechanical, electrical, and optical characteristics, so that it has tremendous potential to be applied to any applications. Especially, grapheme has tighter confinement plasmon and relatively long propagation distances, so that it can enhance the light-matter interactions (F. H. L. Koppens, et al., Nano Lett., 2011). Accordingly, we coated graphene on the optical fiber probe which we fabricated to compose the wavelength-modulated SPR sensor (Figure 1.). The graphene film was synthesized via thermal chemical vapor deposition (CVD) process. Synthesized graphene was transferred on the core exposed region of fiber optic by lift-off method. Detected analytes were biotinylated double cross-over DNA structure (DXB) and Streptavidin (SA) as the ligand-receptor binding model. The preliminary results showed the SPR signal shifts for the DXB and SA binding rather than the concentration change.

  • PDF

Label-free Femtomolar Detection of Cancer Biomarker by Reduced Graphene Oxide Field-effect Transistor

  • Kim, Duck-Jin;Sohn, Il-Yung;Jung, Jin-Heak;Yoon, Ok-Ja;Lee, N.E.;Park, Joon-Shik
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.549-549
    • /
    • 2012
  • Early detection of cancer biomarkers in the blood is of vital importance for reducing the mortality and morbidity in a number of cancers. From this point of view, immunosensors based on nanowire (NW) and carbon nanotube (CNT) field-effect transistors (FETs) that allow the ultra-sensitive, highly specific, and label-free electrical detection of biomarkers received much attention. Nevertheless 1D nano-FET biosensors showed high performance, several challenges remain to be resolved for the uncomplicated, reproducible, low-cost and high-throughput nanofabrication. Recently, two-dimensional (2D) graphene and reduced GO (RGO) nanosheets or films find widespread applications such as clean energy storage and conversion devices, optical detector, field-effect transistors, electromechanical resonators, and chemical & biological sensors. In particular, the graphene- and RGO-FETs devices are very promising for sensing applications because of advantages including large detection area, low noise level in solution, ease of fabrication, and the high sensitivity to ions and biomolecules comparable to 1D nano-FETs. Even though a limited number of biosensor applications including chemical vapor deposition (CVD) grown graphene film for DNA detection, single-layer graphene for protein detection and single-layer graphene or solution-processed RGO film for cell monitoring have been reported, development of facile fabrication methods and full understanding of sensing mechanism are still lacking. Furthermore, there have been no reports on demonstration of ultrasensitive electrical detection of a cancer biomarker using the graphene- or RGO-FET. Here we describe scalable and facile fabrication of reduced graphene oxide FET (RGO-FET) with the capability of label-free, ultrasensitive electrical detection of a cancer biomarker, prostate specific antigen/${\alpha}$ 1-antichymotrypsin (PSA-ACT) complex, in which the ultrathin RGO channel was formed by a uniform self-assembly of two-dimensional RGO nanosheets, and also we will discuss about the immunosensing mechanism.

  • PDF

Polymethylmethacrylate 입자에 표면에 비타민 C의 코팅 (The coating of vitamin C on the surface of polymethylmethacrylate microsphere)

  • 김경희;최성호
    • 분석과학
    • /
    • 제19권6호
    • /
    • pp.468-472
    • /
    • 2006
  • 기능성 화장품 원료로서 관심을 갖는 비타민 C(L-ascobic acid)는 피부에 대한 안전성, 항산화성으로 인해 노화방지 및 미백, 잔주름개선 등의 효능을 갖지만 화학적으로 쉽게 산화된다. 따라서 본 연구에서는 비타민 C의 안정성에 대한 단점을 보완하기 위하여, 에멀젼 중합법으로 다양한 마이크론 크기의 Polymethylmethacrylate(PMMA)입자를 제조하고, 제조된 PMMA의 입자 표면에 코팅용액(물과 에탄올 혼합용매에 cyclodextrin과 비타민 C를 녹인 용액)을 이용하여 비타민 C를 코팅처리 하였다. 코팅처리 후, 실온 및 $40^{\circ}C$에서 시간에 따른 비타민 C의 함량을 조사한 결과, 56일이 경과후에도 비타민 C가 86.4%가 잔존함을 확인 할 수 있었다.

실리카 나노입자 표면에 CdS 나노입자의 제조 및 평가 (Preparation and characterization of CdS nanoparticle on the surface of silica nanoparticles)

  • 강은옥;최성호;;이광필
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.413-418
    • /
    • 2007
  • 방사선 방법에 의해 실리카 나노입자에 CdS 나노입자를 코팅하였다. TEM분석결과, $SiO_2$ 나노입자 표면에 CdS의 입자의 크기는 대략 20 nm임을 확인 하였다. 또한, XRD 분석결과 결정체 화합물임을 확인하였다. PL 분석결과 PVP-CdS 나노입자와 $SiO_2$@CdS 복합체의 경우, 방출특성이 상당히 다르다는 것이 확인되었다. PVP-CdS의 경우, 방출스펙트럼이 550 nm-600 nm 에서 나타나고, $SiO_2$@CdS의 방출스펙트럼의 경우 단파장 이동함을 확인하였다. 또한 새로운 피이크 (450 nm) 나타남을 확인하였는데, 이는 CdS 의 유발양자 제한 효과에 의한 것으로 사료된다.

Fabrication and Characterization of an OTFT-Based Biosensor Using a Biotinylated F8T2 Polymer

  • Lim, Sang-Chul;Yang, Yong-Suk;Kim, Seong-Hyun;Kim, Zin-Sig;Youn, Doo-Hyeb;Zyung, Tae-Hyoung;Kwon, Ji-Young;Hwang, Do-Hoon;Kim, Do-Jin
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.647-652
    • /
    • 2009
  • Solution-processable organic semiconductors have been investigated not only for flexible and large-area electronics but also in the field of biotechnology. In this paper, we report the design and fabrication of biosensors based on completely organic thin-film transistors (OTFTs). The active material of the OTFTs is poly(9,9-dioctylfluorene-co-bithiophene) (F8T2) polymer functionalized with biotin hydrazide. The relationship between the chemoresistive change and the binding of avidin-biotin moieties in the polymer is observed in the output and on/off characteristics of the OTFTs. The exposure of the OTFTs to avidin causes a lowering of ID at $V_D$ = -40 V and $V_G$ = -40 V of nearly five orders of magnitude.

Detection of Avidin Based on Rugate-structured Porous Silicon Interferometer

  • Koh, Young-Dae;Kim, Sung-Jin;Park, Jae-Hyun;Park, Cheol-Young;Cho, Sung-Dong;Woo, Hee-Gweon;Ko, Young-Chun;Sohn, Hong-Lae
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권11호
    • /
    • pp.2083-2088
    • /
    • 2007
  • Biosensor based on rugate PSi interferometer for the detection of avidin has been described. Rugate PSi fabricated by applying a computer-generated pseudo-sinusoidal current waveform has been prepared for the application as a label-free biosensor based on porous silicon interferometer. The fabrication, optical characterization, and surface derivatization of a rugate PSi has been described. The method to fabricate biotinderivatized rugate PSi has been investigated. The surface and cross sectional morphology of rugate PSi are obtained with SEM. FT-IR spectroscopy is used to characterize the oxidation and functionalization reaction of rugate PSi sample. Binding of the avidin into the biotin-derivatized rugate PSi induces a change in refractive index. A red-shift of reflectivity by 18 nm in the reflectivity spectrum is observed, when the biotin-modified rugate PSi was exposed to a flow of avidin.