• 제목/요약/키워드: Nakdong river water system

검색결과 251건 처리시간 0.024초

낙동강변 실트질 모래의 수리전도도와 전기적 물성과의 관계 (A Relationship between Hydraulic Conductivity and Electrical Properties of Silty Sand on the Riverside of the Nakdong River)

  • 김수동;박삼규;함세영;오윤영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권3호
    • /
    • pp.39-46
    • /
    • 2014
  • Hydraulic conductivity is an important parameter, representing permeable property of the groundwater in aquifers, in the issues of groundwater development, groundwater contamination, and groundwater flow, etc. We estimated a relationship between hydraulic conductivity and electrical properties (formation factor, chargeability, and time constant) of silty sand in the laboratory. For this study, we conducted grain size analysis, constant head permeameter test, and measured electrical resistivity and spectral induced polarization of silty sand samples collected from the riverside alluvium of the Nakdong River in Nogok-ri area, Dasan-myeon, Goryeong-gun in Gyeongbook Province, Korea. In the laboratory test, we used soil samples of approximately uniform porosity with 0.5% error range, and kept the electrical resistivity of pore water with 100 ohm-m. As a result, the relationship between effective particle size and hydraulic conductivity agrees fairly well with the existing empirical formulas. Hydraulic conductivity was correlated with formation factor, chargeability, and time constant: hydraulic conductivity increased with increasing formation factor and time constant as well as with decreasing chargeability.

낙동강 유역 수리학적 하도추적 모형 구축 및 적용 (II) 홍수사상의 적용 (The Establishment and Application of Hydraulic Channel Routing Model on the Nakdong River (II) Model Application)

  • 이을래;김상호
    • 한국습지학회지
    • /
    • 제8권1호
    • /
    • pp.83-96
    • /
    • 2006
  • 본 연구에서는 1차원 부정류 해석 모형인 FLDWAV 모형을 이용하여 낙동강 하류지역의 수리학적 특성을 분석하였다. 입력자료 구축을 위해서 KOWACO 홍수분석 모형을 이용한 합리적인 경계조건을 수립하였다. 과거의 홍수 사상에 대해서 적용한 결과 진동, 삼랑진 지점에서의 관측수위와 비교하여 정량적, 정성적인 면에서 일치하고 있는 것으로 나타났다. 또한 낙동강 유역의 하류경계조건으로 입력이 되는 하구둑 수위산정법을 개선하였다. 이를 위해 낙동강 하구에서 발생하는 천문조위와 과거의 하구둑 관측수위를 이용하여 합리적인 예측수위값을 산정하는 회귀방정식을 산정하였다. 본 연구에서 수행된 절차 등을 이용하면 타수계에서의 적용 및 홍수예경보 구축을 위한 지침으로 적용될 수 있을것으로 판단된다.

  • PDF

낙동강 유역 BOD, COD 및 TOC의 수문학적 플럭스 추정 (Estimating BOD, CDO and TOC Hydrologic Flux in Nakdong River Basin)

  • 이아연;박무종;조덕준;김상단
    • 대한환경공학회지
    • /
    • 제32권9호
    • /
    • pp.830-839
    • /
    • 2010
  • 본 연구에서는 현재 시행되고 있는 오염총량관리제 모니터링 시스템에 적용가능한 부하량 추정기법에 대하여 제시하였다. 수정 TANK 모형을 통하여 8일 간격 유량자료의 1일 간격 유량자료로의 확장을 시행하여 유황곡선의 작성을 가능하게 하였다. 7변수 대수 선형 모형 적용 통한 BOD, COD 및 TOC 부하량 추정에서 만족스러운 결과를 확인할 수 있었다. 연구의 적용의 일환으로, 낙동강유역의 BOD, COD 및 TOC 항목의 부하량 유황 곡선을 작성하여 전체적인 분포를 살펴보았다. 본 연구를 통하여 파악된 부하량 유황곡선은 해당 지점의 현재 전체적인 수질현황을 확률적으로 파악할 수 있음과 동시에 이를 시각적으로 도시할 수 있는 장점을 가지고 있다.

낙동강 유역 주요 수질측정지점의 시·공간적 수질특성 분석 (Temporal and Spatial Analysis of Water Quality Data Observed from Major Water Quality Stations in Nakdonggang Watershed)

  • 김소래;조현경;김상민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.545-545
    • /
    • 2017
  • 본 연구에서는 낙동강 유역 본류와 주요 지천의 오염총량관리대상지점을 대상으로 수질 현황과 시공간적 수질특성을 분석을 위해 하수처리장과 주요 지천의 유입으로 인한 낙동강 본류 수질의 공간적 변화양상과 계절별 하천유량의 변화에 따른 수질특성을 분석하였다. 자료구축을 위해 국가수자원관리종합정보시스템(WAMIS)의 하천 공간 지형 자료, 국립환경과학원의 수질관측지점 공간지형자료, 그리고 전국오염원조사 자료의 하수처리장 공간 지형 자료를 이용하였다. 수질자료는 국립환경과학원 물환경정보시스템에서 제공하는 8일 간격 수질자료를 2004년부터 2015년까지 수집하여 이용하였고, 수집한 자료는 갈수기와 전체 기간에 대해 수질 항목(유량, BOD, T-N, T-P)별로 산술 평균하였다. 하수처리장 32개소의 방류수질 자료는 국립환경과학원의 전국오염원조사 자료를 2012년부터 2015년까지 수집하여 갈수기인 봄, 가을철에 대해 수질항목 별로 산술평균하였다.

  • PDF

On-Line SPE-LC/MSD 시스템을 이용한 수중의 과불화 화합물(PFCs) 분석 (Application of On-Line SPE-LC/MSD to Measure Perfluorinated Compounds (PFCs) in Water)

  • 손희종;염훈식;정종문;장성호
    • 대한환경공학회지
    • /
    • 제35권2호
    • /
    • pp.75-83
    • /
    • 2013
  • 본 연구는 기존의 고상추출(SPE) 과정을 분석장비인 LC/MSD에 on-line으로 연결함으로써 cartridge의 건조를 막아 target 물질의 손실을 최대한 억제하였으며 11종의 PFCs에 대해 실제 matrix가 있는 낙동강 원수를 이용한 실험에서 $80.4{\pm}5.2%{\sim}109.5{\pm}1.4%$ 범위의 높은 회수율을 구할 수 있었다. 낙동강에서의 PFCs 분포를 조사한 결과 하수처리장 방류수의 영향을 받는 지역(진천천과 금호강 하류)은 고농도의 PFCs가 검출되었으며, 낙동강 하류의 매리원수에서는 검출농도가 급격히 감소하여 PFOA만 8.0 ng/L의 농도로 검출되었다. 외국의 PFCs 검출현황을 보고한 연구결과들과 비교해 볼 때 낙동강 지류에서는 비교적 높은 농도로 PFCs가 검출되어 안심할 수 있는 수준은 아니었으며, 낙동강 본류의 경우도 여러 지역의 상수원으로 이용되기 때문에 주기적인 모니터링이 필요한 것으로 나타났다.

수질오염총량관리를 위한 관리대상물질 (Applicable Water Quality Indicators for Watershed Management)

  • 박재홍;오승영;박배경;공동수;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1004-1013
    • /
    • 2006
  • To effective a watershed management, it is necessary to have one or more quantitative measures that can be used to evaluate the relationship between pollutant sources and their impact on water quality. Such measurable quantities are termed indicators. Once an indicator has been selected, a target value for that indicator must be established that seek to distinguish between the impaired and unimpaired state of the waterbody. Various factors will be considered for the selection of an appropriate watershed management indicator. For example, available data, application, management conditions, cost, etc. This paper lists various factors that should be addressed in choosing a watershed management indicators and investigates applicable indicators during watershed management period.

Long-Term Monitoring of Noxious Bacteria for Construction of Assurance Management System of Water Resources in Natural Status of the Republic of Korea

  • Bahk, Young Yil;Kim, Hyun Sook;Rhee, Ok-Jae;You, Kyung-A;Bae, Kyung Seon;Lee, Woojoo;Kim, Tong-Soo;Lee, Sang-Seob
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권10호
    • /
    • pp.1516-1524
    • /
    • 2020
  • Climate change is expected to affect not only availability and quality of water, the valuable resource of human life on Earth, but also ultimately public health issue. A six-year monitoring (total 20 times) of Escherichia coli O157, Salmonella enterica, Legionella pneumophila, Shigella sonnei, Campylobacter jejuni, and Vibrio cholerae was conducted at five raw water sampling sites including two lakes, Hyundo region (Geum River) and two locations near Water Intake Plants of Han River (Guui region) and Nakdong River (Moolgeum region). A total 100 samples of 40 L water were tested. Most of the targeted bacteria were found in 77% of the samples and at least one of the target bacteria was detected (65%). Among all the detected bacteria, E. coli O157 were the most prevalent with a detection frequency of 22%, while S. sonnei was the least prevalent with a detection frequency of 2%. Nearly all the bacteria (except for S. sonnei) were present in samples from Lake Soyang, Lake Juam, and the Moolgeum region in Nakdong River, while C. jejuni was detected in those from the Guui region in Han River. During the six-year sampling period, individual targeted noxious bacteria in water samples exhibited seasonal patterns in their occurrence that were different from the indicator bacteria levels in the water samples. The fact that they were detected in the five Korea's representative water environments make it necessary to establish the chemical and biological analysis for noxious bacteria and sophisticated management systems in response to climate change.

낙동강 수계에서의 Perchlorate 검출 및 활성탄 공정에 의한 제거특성 (Detection of Perchlorate in Nakdong River and Removal Characteristics of Perchlorate by Granular Activated Carbon Process)

  • 손희종;정철우
    • 대한환경공학회지
    • /
    • 제29권4호
    • /
    • pp.438-443
    • /
    • 2007
  • 2006년 6월부터 12월까지 낙동강 본류 및 주요 지천들에서의 perchlorate 검출현황을 조사한 결과, 2006년 6월에 구미 하류인 왜관에서 82.1 ${\mu}g/L$가 검출되었으며, 고령에서 34.1 ${\mu}g/L$, 대암 18.3 ${\mu}g/L$, 적포 12.6 ${\mu}g/L$, 남지 13.6 ${\mu}g/L$ 및 부산시 상수 취수원인 물금에서 7.6 ${\mu}g/L$가 검출되었다. 이런 결과는 구미와 왜관 사이에 perchlorate 오염원이 존재하는 것을 의미하며, 하류로 갈수록 perchlorate 검출농도가 낮아졌다. 또한, 2006년 7월부터 12월까지 채수한 낙동강 본류 및 지천 시료에서는 perchlorate가 전혀 검출되지 않아 2006년 6월에 일시적으로 perchlorate가 구미와 왜관 사이의 본류에서 유출된 것으로 나타났다. 활성탄 공정에서의 perchlorate 제거 특성을 조사한 결과, 3.1년 사용탄에서는 활성탄 재질별로 거의 흡착능이 없었으며, 석탄계 및 야자계 재질의 활정탄 신탄에서는 운전초기에는 흡착 제거되어지나, 목탄계 활성탄에서는 신탄에서도 제거능이 낮았으며, 석탄계 신탄은 BV 2,300 정도에서 파과에 도달하였고, 야자계와 목탄계 신탄의 파과시점은 BV 719와 288 정도로 나타났다. 또한, 활성탄 g당 perchlorate에 대한 최대 흡착량(X/M)은 석탄계 활성탄이 $768.2{\mu}g/L$으로 가장 높았으며, 다음으로 야자계 $299{\mu}g/L$, 목탄계 $99.2{\mu}g/L$로 나타났다. CUR의 경우 석탄계 활성탄은 0.71 g/일, 야자계와 목탄계 활성탄은 2.16 g/일과 3.45 g/일로 나타났다. 석탄계, 야자계 및 목탄계 활성탄의 k값은 각각 307.2, 102.5 및 94.2로 나타났다.

수질오염물질 감소의 편익 추정 -수질총량제하 가상배출권시장 개념의 적용- (Valuation of the Water Pollution Reduction: An Application of the Imaginary Emission Market Concept)

  • 한택환;이효창
    • 자원ㆍ환경경제연구
    • /
    • 제23권4호
    • /
    • pp.719-746
    • /
    • 2014
  • 본 연구는 수질오염물질에 대한 가상적 배출권거래시장을 상정하여 균형배출권가격을 도출함으로써 수질개선에 따른 편익을 추정하려고 시도하였다. 우리나라에서는 낙동강수계를 비롯하여 주요 수계에 수질오염물질 총량관리제도가 실시되고 있다. 사회적으로 바람직스러운 배출총량을 결정함으로써 국민과 정부는 암묵적으로 수질오염물질의 경제적 가치를 결정한 것과 같다고 할 수 있다. 각 지자체별로 수질오염물질 배출상의 제약으로 인하여 희생된 경제적 기회비용이 발생할 것이며 이 기회비용의 크기가 수질오염물질의 경제적 가치이기 때문이다. 이 가상적 배출권거래시장에서의 균형가격을 수질 총량제하의 수계전체의 배출총량과 지자체별 할당에 의하여 암묵적으로 결정된 수질오염물질 배출의 단위당 가치라고 해석할 수 있다. 배출량과 편익의 관계로부터 한계순편익함수를 도출하고 지자체별 배출허용총량을 이용하여 개별배출권 초과수요함수를 구성하여 균형배출권가격을 도출하였다. 추정 결과 배출권시장의 균형배출권가격이 1,409.3원/$kg{\cdot}BOD$으로 추산되었다. 이는 외국의 사례와 비교하여 적정한 수준이라 평가되며 이러한 배출권가격은 수질 오염물질의 단위당 경제적 가치를 산정하여 수질변화를 수반하는 사업의 B/C분석에 직접적으로 이용할 수 있을 것으로 기대된다.

남강댐 유역에서의 기후변화에 대한 유출 영향 (Impact of Climate Change on Runoff in Namgang Dam Watershed)

  • 이종문;김영도;강부식;이혜숙
    • 한국수자원학회논문집
    • /
    • 제45권6호
    • /
    • pp.517-529
    • /
    • 2012
  • 기후변화는 유역의 수문과정에 영향을 줄 수 있으며, 최적의 수자원 관리를 위해서는 이와 같은 기후변화로 인한 수환경 영향을 예측 및 분석하기 위한 통합적인 모의체계의 구축이 필요하다. 본 연구에서는 낙동강 수계의 남강댐 유역을 대상지역으로 선정하여, 기후변화 취약성을 평가하기 위하여 SWAT 모형을 이용하여 유출량 변화를 예측하였다. 기후시나리오 생산을 위하여 지역기후모형(RCM)의 분석 및 인공신경망을 통한 상세화기법을 적용하여 예측인자들에 대한 모의결과로부터 미래 기상자료를 구축하였다. 또한 강우의 경우 총량에 대한 보정을 위해 분위사상법을 적용하였다. 이와같은 시나리오를 검보정이 완료된 SWAT 모형에 적용하여 기후변화에 따른 유출량 변화를 예측하였다. 본 연구의 결과를 이용하여 기후변화에 대한 효율적인 대책을 제시하여 최적의 수자원관리방안을 도출할 수 있을 것으로 판단된다.