• Title/Summary/Keyword: NaI(Te)

Search Result 23, Processing Time 0.032 seconds

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

Synthesis and Spectroscopic Investigations of Some New rganotelluronium alts Based on Dicyclohexyl Telluride (디시클로헥실 텔루르염에 기반한 유기텔루로늄염의 성과 분광학적 분석)

  • Al-Rubaie, Ali Z.;Al-Mudhaffar, Dhafir M. H.;Al-Mowali, Ali H.;Asker, Kahtan A.
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.5
    • /
    • pp.530-535
    • /
    • 2009
  • Dicyclohexyl telluride was obtained in a high yield by the reaction of cyclohexyl bromide with NaTeH(prepared in situ) in an aqueous ethanolic solution. A series of new organotelluronium salts of the general formula ${(cyclo-C_6H_11)}_2Te(R)X$ (where R = $CH_3$, X = I (1); R = $C_2H_5$, X = Br(2); R = $C_2H_5$, X = I (3); R = C_3H_5$, X = Br (4)) were prepared by the reaction of ${(cyclo-C_6H_11)}_2Te$ with the corresponding alkyl halide. Reaction of 1 with NaBPh4 gave compound 5 ( i.e. R = CH3, X = BPh4 ‒) in 78% yield. Reaction of ${(cyclo-C_6H_11)}_2Te$ with benzyl bromide and 4-bromophenacyl bromide gave unexpectedly dibenzylcyclohexyltelluronium bromide (6) and bis(4-bromophenacyl)cyclohexyltelluronium bromide (7), respectively. Reaction of 6 with NaBPh4 gave the corresponding tetraphenylborate derivative (8) in high yield. $^1H$ NMR studies revealed that in $CDCl_3$solution compound 1 eliminated alkyl halide. Conductivity, IR, $^1H\;and\;^{13}C$ NMR and thermal data for the new compounds are presented and discussed.

The Development of Iodine-123 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구)

  • Suh, Yong-Sup;Yang, Seung-Tae;Chun, Kown-Soo;Lee, Jong-Doo;Han, Hyon-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

Evaluation of Image Quality by Using Various Detector Materials according to Density : Monte Carlo Simulation Study (몬테카를로 시뮬레이션 기반 밀도에 따른 다양한 검출기 물질을 적용한 획득 영상 평가)

  • LEE, Na-Num;Choi, Da-Som;Lee, Ji-Su;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.459-464
    • /
    • 2021
  • The detector performance is important role in acquiring the gamma rays from patients. Among parameters of detector performances, there is density, which relates to respond to gamma rays. Therefore, we confirm the detection efficiency according to various detector materials based on the density parameter using GATE (geant4 application for emission tomography) simulation tool. The NaI (density: 3.67 g/cm3), CZT (Cadimium Zinc Telluride) (density: 5.80 g/cm3), CdTe (Cadmium Telluride) (5.85 g/cm3), and GAGG (Gadoinium Aluminum Gallium Garnet) (density g/cm3) were used as detector materials. In addition, the point source and quadrant bar phantom, which is modeled for 0.5, 1.0, 1.5, and 2.0 mm thicknesses, were modeled to confirm the quatitative analysis using sensitivity (cps/MBq) and the full width at half maximum (FWHM, mm) at the 2.0 mm bar thickness containing visual evaluation. Based on the results, the sensitivity for NaI, CZT, CdTe, and GAGG detector materials were 0.12, 0.15, 0.16, and 0.18 cps/MBq. In addition, the FWHM for quadrant bar phantom in the 2.0 mm bar thickness is 3.72, 3.69, 3.70, and 3.73 mm for NaI, CZT, CdTe, and GAGG materials, respectively. Compared with performance of detector materials according to density, the high density can improve detection efficiency in terms of sensitivity and mean count. Among these detector materials, the GAGG material is efficient for detection of gamma rays.

SIPPING TEST: CHECKING FOR FAILURE OF FUEL ELEMENTS AT THE OPAL REACTOR

  • Smith, Michael Leslie;Bignell, Lindsey Jorden;Alexiev, Dimitri;Mo, Li
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.125-130
    • /
    • 2010
  • Sipping measurements were implemented at the Open Pool Australian Light water reactor (OPAL) to test for failure in reactor fuel elements. Fission product released by the fuel element into the pool water was measured using both High Purity Germanium (HPGe) detection via samples and a NaI(Tl) detection in-situ with the sipping device. Results from two fuel elements are presented.

The Recovery of Tellurium from Copper Anode Slimes by Hydrometallurgical Processes

  • Lee, Churl-Kyoung;Rhee, Kang-In;Sohn, Hun-Joon
    • Resources Recycling
    • /
    • v.6 no.3
    • /
    • pp.41-45
    • /
    • 1997
  • The recovery of tellurium from Te-cement obtained during the processing of copper anode slimes was carried out by a series of hydrometallurgical processes, i.E. leaching Te-cement in NaOH solution, precipitation of impurities with the addition of ${Na}_{2}S$ followed by direct electrowinning of tellurium in NaOH solution. The optimum conditions for each process were determined and discussed in terms of various parameters associated with each step to maximize the recovery and purity of tellurium. The final purity of tellurium from electrownning in alkaline solution was found to be more than 99.9%.

  • PDF

The Separation of the Impurities in Bismuth Metal by Ion Exchange Resins and Colorimetric Determination (이온交換樹脂에 依한 蒼鉛 中 不純物의 分離定量 (I))

  • Park, Myon-Yong
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.2
    • /
    • pp.47-50
    • /
    • 1968
  • Two methods for separation of the impurities from bismuth metal have been found by the use of Dowex $1{\times}4,$ anion exchange resins. The first method is that Dowex $1{\times}4$ resins are packed into the two stage columns (height of under stage is 22cm and upper stage is 3cm, and diameter of columns are 1.5cm), and the impurities of Pb(II), Ag(I) and Cu(II) are separated by the eluent of 7.5M HCl soln, Zn(II), Fe(III) by 0.5M HCl solns, and Te(IV) in the upper stage by 2M NaOH soln. Remained Au(III) in the upper stage is determined by the ignition with resins. The 2nd method is that for the separation of all the impurities simultaneously the same resins are packed into single stage column(height is 10cm and diameter is 1.5cm), and all the impurities of Pb(II), Zn(II), Cu(II), Fe(III) and Ag(I) are eluted by the eluent of 0.5M HCl soln. Separated impurities are determined by the colorimetry.

  • PDF

The Study on Fish Diseases with Reference to Bacterial Susceptibility to Antibiotics in the Southern Area of Kyeognam (경남 남부지역 양식어류 질병에서 항생제 감수성에 관한 연구)

  • 허정호;정명호;조명희;김국헌;이국천;김재훈;정태성
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.19-22
    • /
    • 2002
  • The examination with 96 bacteria isolates for antibiotics susceptibility was resulted in exploring many antibiotics resistance isolates from the diseased fishes. Vibrio sp. isolates were demonstrated over 90% resistances for Penicillin (P), Amoxicillin (Amc), Erythromycin (I), Colistin (CL). Streptomycin (S). Novobiocin (NV) and Neomycin(N), these isolates were, however, appeared over 80% susceptibilities for Norfloxacin (Nor), CE and UB. In Edwardsiella tarda case, 90 to 100% high resistance was observed for P, Doxycycline (Do), Tetracyclin (Te), Oxytetracycline (T), E, CL, Sulfamethoxasoletrimetoprim (SXT), S, Oxolinic acid (OA), W, Neomycin(N), on the contrary, 90 to 100% high susceptibilities was found for Amc, Nor, Ciprofloxacin (Cip), Orbifloxacin (ORB), Enrofloxacin (ENR), Flumeguine (UB) and NA. CL, Pefloxacin (PEF),S, Flumeguine (UB), OA, NA, NV N was exhibited 90 to 100% resistances for Streptococcus sp., on the other hand, 100% susceptible to AMC and 80% susceptible to Do, Te, ENR and UB was recognised. Lastly, Photobacterium damsela subsp. piscicida was showed 100fe susceptible to Amc and 86% susceptible to NOR, CIP ENR and UB. As a consequence, fish bacterial pathogens isolated from Kyeongnam area, especially Tongyeong-si, Geoje-si, and Goseong-gun, were showed highly resistant to a variety of antibiotics available in the field.

A Study on the Nuclear Structure through the Multipurpose Coincidence Measurement System Development (II) - Double ionization of the K-shell in $^{125}I$- (다목적 동시측정 장치 개발에 의한 원자핵 구조 연구 (II) - $^{125}I$ 붕괴시 K 각 이중 이온화 현상 -)

  • Chung, Won-Mo;Chung, Kap-Soo;Joo, Koan-Sik;Nam, Kie-Yong;Choi, Hey-Jin;Jeon, Woo-Ju;Na, Sang-Kyun;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.63-70
    • /
    • 1993
  • Double ionization of the K- shell accompanying K- shell electron capture of the 0.035 MeV transition of $^{125}I$ has been studied by counting coincidences between $K_{\alpha}$ hypersatellite X-rays and Ka satellite X-rays emitted when double vacancies are filled. The $^{125}I\;and\;^{125}Te^m$ source materials were used in the measurement. We obtained the coincidence spectrum using two NaI(T1) detectors and a Ge(Li) detector and TAC(Time-to-Amplitude Converter), and then analysed the measured coincidence number $N(K_{\alpha}^{II},\;K_{\alpha}^s)$, the total number $N(K_{\alpha})$ of K X-ray. The probability per K-shell electron capture that a double vacancy is formed, $P_{KK}$ is formed, $P_{KK}$ is found to be $2.15{\times}10^{-4}$.

  • PDF

Serotyping and antibiotic susceptibility of Salmonella species from pigs with rectal stricture found in slaughterhouses (도축장 출하 직장협착 돼지에서 분리된 살모넬라균 혈청형 및 항생제 감수성)

  • Jiyeon Kim;Jinju Gwak;Doori Seo;Jaegi Lee;Daewoong Lim;Hana Kim;Jiyeong Park;Jongwoog Choi;Byeongcheol Yoon
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.2
    • /
    • pp.137-145
    • /
    • 2023
  • From November 2021 to October 2022, 151 pigs were discarded due to the suspected salmonellosis, when assessed by antemortem inspection at slaughterhouses in Gwangju. Among them, 85 cases shown with the rectal stricture were confirmed to be infected with Salmonella spp, when assessed by postmortem inspection and Salmonella-oriented culture in the laboratory, accounting for 56.3% of the carcass discard cases. Salmonella spp. were isolated in 58 cases (68.2%) out of 85 total discard cases. As for serotyping of the Salmonella isolates, 28 cases (48.3%) belonged to serogroup B and 28 cases (48.3%) belonged to serogroup C, those were the most frequent isolates, and 2 cases (3.4%) belonged to serogroup E. The most prevalent serotype was Rissen (39.7%), followed by I4,[5],12:i:-(37.9%), Derby (8.6%), Bareilly (5.2%), Infantis (3.4%), Give (3.4%), and Typhimurium (1.7%). The 58 isolates of salmonellae showed resistance to tetracycline (63.8%), chloramphenicol (56.9%), ampicillin (53.4%), and ampicillin-sulbactam (51.7%). S. Rissen showed resistance to chloramphenicol (82.6%), ampicillin (52.2%), ampicillin-sulbactam (52.2%), and tetracyclin (47.8%). S. I4,[5],12:i:-was resistant to tetracycline (90.9%), ampicillin (81.8%), ampicillin-sulbactam (77.3%), and chloramphenicol (59.1%). Among the isoates, S. Bareilly (3 strains), S. Infantis (2 strains), S. Give (2 strains), S. Rissen (3 strains), and S. I4,[5],12:i:- (1 strain) showed no resistance to the tested antimicrobials. As for the prevalence of the antibiotic resistance pattern, AM-SAM-TE-C was the most common, which was shown in 15.5% of S. Rissen. At second, the resistance pattern was occurred as AM-SAM-TE (12.1%) and AM-SAM-CF-CZ-FOX-CTX-NA-TE-C (12.1%), respectively in the case of S. I4,[5],12:i:-.