DOI QR코드

DOI QR Code

SIPPING TEST: CHECKING FOR FAILURE OF FUEL ELEMENTS AT THE OPAL REACTOR

  • Published : 2010.02.28

Abstract

Sipping measurements were implemented at the Open Pool Australian Light water reactor (OPAL) to test for failure in reactor fuel elements. Fission product released by the fuel element into the pool water was measured using both High Purity Germanium (HPGe) detection via samples and a NaI(Tl) detection in-situ with the sipping device. Results from two fuel elements are presented.

Keywords

References

  1. C, A. Zeituni, L. A. A. Terremoto, and J, E. R. da Silva, in Failed MTR Fuel Element Detect in a Sipping Tests, United States, 2004, p, Size: 8 pages;
  2. Y. K. Bibilashvilli, Atomic Energy 36, 289- 292 (1974), https://doi.org/10.1007/BF01223185
  3. J, A. Perrotta, L. A. A. Terremoto, and C. A. Zeituni, Annals of Nuclear Energy 25,237-258 (1998), https://doi.org/10.1016/S0306-4549(97)00039-X
  4. P, Tipping, International Journal of Pressure Vessels and Piping 66, 17-25 (1996), https://doi.org/10.1016/0308-0161(95)00082-8
  5. F, Piton, M,-C, Lepy, M,-M, Be, and J. Plagnard, Applied Radiation and Isotopes 52, 791-795 (2000), https://doi.org/10.1016/S0969-8043(99)00246-8
  6. M,-C, Lepy, M,-M, Be, and p, Piton, Laboratoire National Henri Becquerel Note Technique LNHB/01/09/A (2004),
  7. W, T, o, R, Isotopes, http://nucleardata,nuclear.lu,se/ nucleardata/toi,
  8. (Labomtoire National Henri Becquerel http://laraweb,free,fr),
  9. R. Nicolini, F, Camera, N, Blasi, S, Brambilla, R. Bassini, C, Boiano, A. Bracco, F, C, L. Crespi, O, Wieland, G, Benzoni, S, Leoni, B. Million, D, Montanari, and A. Zalite, Nuclear Instruments and Methods in Physics Research A 582, 554 - 561 (2007), https://doi.org/10.1016/j.nima.2007.08.221
  10. D, Alexiev, L. Mo, D, A. Prokopovich, M, L. Smith, and M, Matuchovac, IEEE Transactions on Nuclear Science, Article in press (2008),