PP, NY섬유를 혼입한 150MPa 콘크리트의 고온역학적 특성 (Evaluation on High-Temperature Mechanical Properties of 150MPa Concrete Mixed with PP and NY Fiber)

  • 백재욱;김규용;윤민호;황의철;손민재;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.5-6
    • /
    • 2017
  • Ultra high-strength concrete can prevent spalling by mixed ratio of PP and NY fiber. However, there is a lack of research on the deterioration of strength due to changes in mechanical properties after spalling prevention. In this study, the effect of high temperature on the mechanical properties of 150MPa concrete mixed with PP and NY fiber was evaluated. As a result, mixing PP and NY fiber is judge to be little effect on the mechanical properties of the 150MPa concrete at high temperature.

  • PDF

가압가열 방식에 의한 Brown Stock의 유통 중 품질 변화 (The Quality Characteristics of Brown Stock Prepared by The High Pressure Cooking)

  • 최수근;최희선
    • 동아시아식생활학회지
    • /
    • 제13권6호
    • /
    • pp.615-623
    • /
    • 2003
  • This study has been conducted to develop brown stock with the high pressure cooking(HPC) method. The sterilization methods, package film and storage methods, and quality maintenance during storage were investigated in this study. The packaging quality of NY/PP was inferior to that of PE/AL/PP since NY/PP facilitated the ventilation and moisture absorption. The maximum duration of the safe storage was found to be 50 days at 25$^{\circ}C$, 30 days at 35$^{\circ}C$ for NY/PP package film, and 60 days at 25$^{\circ}C$, 40 days at 35$^{\circ}C$ for PE/AL/PP one. These results showed that the overall quality of brown stock by the HPC method was not different significantly from that of brown stock by the traditional approach. Furthermore, the HPC approach might improve the productivity by saving the labour cost, food cost, and cooking time. Therefore, the traditional method might well be substituted by this newly developed method.

  • PDF

섬유 종류가 도로포장용 콘크리트의 기초적 특성에 미치는 영향 (Effect of Fiber Types on Fundamental Properties of Pavement Concrete)

  • 한천구;박종섭;정우태;전규남
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.473-479
    • /
    • 2010
  • 이 연구에서는 도로포장용 콘크리트의 성능향상을 목적으로 폴리프로필렌(PP), 나일론(NY), 폴리비닐알코올(PVA) 및 셀룰로우스(CL)의 섬유 종류에 변화를 주어 도로포장용 섬유보강 콘크리트(FRC)의 공학적 특성을 분석하였다. 그 결과 굳지 않은 콘크리트의 특성으로 유동성은 OPC에 비해 섬유를 혼입할 경우 저하하는 경향을 나타내었으나, 혼합 즉시는 PP섬유, 60분 경시변화까지도 고려하면 NY섬유에서 가장 우수한 것으로 나타났다. 공기량은 OPC와 유사한 경향을 나타내며, 섬유 혼입으로 인한 공기량의 변화는 크지 않았다. 경화 콘크리트의 특성으로 압축강도 및 휨강도는 Plain에 비하여 모든 재령에서 섬유를 혼입할 경우 증가하는 경향을 나타내었는데, 섬유 종류별로는 NY, PVA, PP, CL순이었다. 단, 인장강도에서는 NY 및 PP일 경우만 증가하는 경향이었다. 포로시미터에 의한 세공분포는 NY섬유를 혼입할 경우 섬유의 영향으로 $1{\mu}m$ 전후의 세공량이 많이 분포하여 누적 세공량이 커지는 경향을 나타내었다. 따라서 유동성 및 강도 등을 종합적으로 고려할 때, 이 연구의 실험 조건에서는 NY섬유 혼입 시 최상의 결과가 도출되는 것으로 분석되었다.

복합섬유(PP,NY)를 혼입한 설계강도 80MPa 3성분계 고강도콘크리트의 폭렬특성 (Spalling Properties of 80MPa High Strength Concrete with Fiber)

  • 김성덕;이범식;배기선;김상연;박수희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.51-54
    • /
    • 2009
  • In this study, the fire resistance test was carried out with a parameter such as fiber(PP+NY) mixed ratio on high strength concrete with 80MPa, and the spalling resistance property was evaluated. Concrete material test was carried out with a parameter such as fiber(PP+NY) mixed ratio(0%, 0.05%, 0.1%, 0.2%) of high strength concrete with 80MPa. Although the flowability and the strength capacity were delicately decreased with a increase of fiber mixed ratio, they satisfied the target limits. As the spalling resistance property after the fire resistance test of 3 hours, the spalling was partly shown on the high strength concrete with fiber(PP+NY) mixed ratio of 0% but, wasn't shown on the high strength concrete with fiber(PP+NY) mixed ratio of 0.05% ~ 0.2%.

  • PDF

3성분계 복합유기섬유 혼입율 변화에 따른 고강도 콘크리트의 내화특성 (Fire Resistance of the High Strength Concrete Depending on Ternary Blended Organic Fiber)

  • 박천진;한상윤;백대현;한민철;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.397-398
    • /
    • 2010
  • 본 연구는 PP, NY, CL의 유기섬유 조합비율 변화에 따른 고강도 콘크리트의 내화특성을 분석한 것으로, PP+NY+CL=0.02+0.01+0.02의 경우가 여타의 섬유 조합보다 내화특성이 우수한 것으로 나타나 최적조합비율인 것으로 판단된다.

  • PDF

섬유의 종류 및 온도가열곡선 변화에 따른 콘크리트의 내화특성 (Fire Resistance of the Concrete Corresponding to the Various Fiber Contents and Heating Curves)

  • 한천구;배장춘
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.101-107
    • /
    • 2008
  • This study investigated fundamental characters of the concrete according to various fiber types and contents and their properties of spatting resistance and residual compressive strength after fire test corresponding to ISO and RABT heating corves. The results were summarized as following. The Flowability was gradually declined as the increase of fiber contents, and it was the most favorable with nylon(NY) fibers. The decrease of air contents due to increasing fiber contents was in order by polypropylene(PP), polyvinyl alcohol(PVA) and NY fibers. The compressive strengths were over 40 MPa at 7 days and 50 MPa at 28 days. It was in order by PVA, PP and NY fibers. For the spatting properties, all specimens were prevented at ISO heating curve. In the other hand, the partial spatting at the surface occurred on the plain without fibers, but it was prevented over 0.10 % of PVA and 0.05 % of PP and NY fibers at the RABT heating curve.

복합섬유(PP, NY)를 혼입한 60, 80MPa 3성분계 고강도콘크리트의 내화특성 (Spalling Properties of 60, 80MPa High Strength Concrete with Fiber)

  • 김성덕;김상연;배기선;박수희;이범식
    • 한국건축시공학회지
    • /
    • 제10권4호
    • /
    • pp.3-9
    • /
    • 2010
  • 본 연구는 고강도콘크리트의 내화성능 증진에 효과적인 것으로 알려진 섬유(PP+NY) 혼입율 변화에 따른 60 MPa, 80 MPa 3성분계 고강도콘크리트의 유동성 및 강도특성을 검토하고 내화시험을 통해 폭렬현상을 확인하였다. 섬유(PP+NY) 혼입율을 0%, 0.05%, 0.1%, 0.2%로 산정하여 실험한 결과, 유동성 및 강도가 미세하지만 저하하는 것으로 나타났으나, 전반적으로 목표 범위를 만족하는 것으로 나타났다. 3시간 내화 후 폭렬특성으로 0%에서는 폭렬현상이 나타났지만, 0.05%이상에서는 표면에 미세한 균열만 발생하고 피복 탈락현상은 나타나지 않는 것으로 나타났다. 또한 폭렬이 발생되지 않은 공시체의 경우 잔존압축강도율이 5 ~ 6%로 나타났다. 이상 적은 양의 섬유(PP+NY)혼입율인 0.05%이상에서 폭렬현상이 방지되어 가장 양호한 것으로 판단된다.

복합유기섬유를 사용한 고강도 콘크리트의 기초특성 및 폭렬방지 (Fundamental Properties and Spalling Resistance of High Strength Concrete Containing Hybrid Organic fiber)

  • 배장춘;한동엽;이진우;한창평;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.745-748
    • /
    • 2006
  • This study investigates the fundamental properties and examines spalling appearances and residual compressive strength of high strength concrete containing hybrid organic fibers subjected to fire. Test showed that overall, an increase of fiber content decreased the fluidity of concrete, but specimens containing polyvinyl alcoho(PVA)+polypropylene(PP) fiber and nylon(NY)+PP fiber had improved flow. In addition, the air content of all specimens was properly ranged in target value, regardless of fiber content. As for the spalling properties when completed the fire test, control concrete exhibited spalling occurrence due to sudden elevated temperature. However, specimens containing more than 0.1 vol% of PP fiber prevented the spalling, while specimens containing PP+CL and PVA+PP fiber can protected from fire in more than 0.15vol% of the fiber content. Importantly, a specimen containing only 0.05vol% of NY+PP showed the favorable spalling resistance performance.

  • PDF

유기섬유 복합 혼입 고성능 콘크리트의 기초적 특성 (Basic Characteristics of High Performance Concrete Mixing Organic Fiber)

  • 박병관;유지영;이정아;김성일;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.87-91
    • /
    • 2008
  • The study examined fire resistance of concrete followed by change of mixed rate in PP and NY composite fiber and the results were as follows. In the event of fluidity in concrete not set, plane satisfied 600±100, its target slump flow, and fluidity was reduced as organic fiber's mixed rate was increased. Air amount satisfied 3.0±1.0, its target air amount, and didn't have distinct differences in reduction and increase according to organic fiber's kind and change of its mixed rate. However, it had a tendency that fluidity was reduced as the mixed rate was increased. In characteristics of hardening concrete, the 28th day compressive strength followed by organic fiber's kind and change of its mixed rate didn't have a lot of differences and satisfied high strength scope as about 70MPa. In spalling characteristics after fire resistance test, spalling was happened in non-mixture, plane combination, and P1N0. In other combinations, spalling resistance was happened. The relic compressive strength rate was 56%, the best condition, in P3N1(PP0.03%, NY0.01% compositeness) mixing PP fiber with NY fiber at once.

  • PDF

폭렬방지공법 변화에 따른 RC 기둥부재의 내화특성 (Fire Resistant Properties of the RC Columns Applying Various Splling Prevention Methods)

  • 한천구;배장춘;이종석;이찬영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권3호통권55호
    • /
    • pp.119-126
    • /
    • 2009
  • 본 연구에서는 RC 기둥의 폭렬방지를 위하여 유기섬유의 혼입방식, 내화보드 부착방식, 스프레이 방식의 폭렬방지공법에 따른 내화특성을 검토하였는데, 그 결과를 요약하면 다음과 같다. 굳지않은 콘크리트의 특성으로, 유기섬유의 혼입율이 증가에 따른 유동성은 저하하는 것으로 나타났고, 섬유의 종류에 따라서는 NY섬유를 혼합한 경우 가장 양호하였다. 공기량은 NY섬유가 가장 적게 저하하였고, 그 다음으로 PVA, PP순이었다. 경화 콘크리트의 특성으로, 압축강도는 28일 재령에서 50MPa이상으로 섬유의 혼입율이 증가할 수록 약간 크게 나타났다. 내화시험후 폭렬특성으로, 유기섬유 혼입방식의 경우 PVA섬유를 제외한 PP섬유, NY 섬유는 혼입율 0.05%이상에서 폭렬이 발생하지 않는 것으로 나타났다. 스프레이 방식의 경우는 모든 마감재 부분에서 부분적인 폭렬이 발생하였을 뿐, 모재 콘크리트는 폭렬이 발생하지 않고 본래의 형상을 그대로 유지하는 것으로 나타났다. 또한, 보드방식의 경우는 보편적인 일반 건식공법인 경우를 제외한 건식공법 시공 후 내화페인트로 연결철물을 도포한 경우, 내화모르터로 차폐한 경우, 경량기포 콘크리트로 그라우트 한 경우는 모두 폭렬이 발생하지 않고 본래의 형상을 그대로 유지하고 있었다. 질량감소율은 플레인 콘크리트를 제외한 내화시공공법변화에 따라서 공히 8%미만으로 비교적 양호하게 나타났다.