• 제목/요약/키워드: NVP

검색결과 55건 처리시간 0.023초

Physical Properties of Ophthalmic Hydrogel Polymer Containing Zinc Oxide Nanoparticles

  • Sung, A-Young;Kim, Tae-Hun
    • 통합자연과학논문집
    • /
    • 제6권2호
    • /
    • pp.76-81
    • /
    • 2013
  • ZnO nanoparticles and vinyl pyridine were added to the mixture of MMA (methyl methacrylate), HEMA (2-hydroxy ethyl methacrylate) and NVP (N-vinylpyrrolidone) in a mould at various concentrations. Cross-linker EGDMA (ethyleneglycoldimethacrylate) and AIBN (azobisisobutyronitrile) initiator were finally added to the mixture and then heated at $80^{\circ}C$ for 60 min to prepare high-performance hydrogel ophthalmic lens. The physical properties of the hydrogel ophthalmic material were investigated by measuring the average value of refractive index, water content and optical transmittance. The refractive index of 1.429~1.450, water content of 34~41%, and visible transmittance of 78~90% were obtained. The material is possibly used to manufacture UV-block hydrogel contact lens.

카르복시메칠 셀룰로오스 성분이 포함된 인공누액이 하이드로젤 콘택트렌즈의 물성에 미치는 영향 (Influence of Artificial Tear Containing Carboxymethyl Cellulose Component on Physical Properties of Hydrogel Contact lens)

  • 조선아;성아영
    • 한국안광학회지
    • /
    • 제18권4호
    • /
    • pp.457-463
    • /
    • 2013
  • 목적: 본 연구는 하이드로젤 콘택트렌즈에 미치는 카르복시메칠 셀룰로오스나트륨을 포함한 인공누액의 영향을 다양한 조건에서 분석 하였다. 방법: 렌즈 재료로 사용되는 NVP(N-vinyl-2-pyrrolidone) 및 MMA(methyl methacrylate)를 가교제인 Ethylene glycol dimethacrylate를 사용하여 HEMA(2-hydroxyethyl methacrylate)와 공중합 하였으며, 개시제로는 azobisiobutyonitrile을 사용하였다. 또한 제조된 렌즈의 물리적 특성을 평가하기 위해 함수율, 굴절률, 접촉각 그리고 분광투과율 등을 측정하였다. 결과: 제조된 콘택트렌즈의 기본 물성을 측정한 결과, 함수율 26.61% ~ 48.58%, 굴절률 1.422~1.455 그리고 분광투과율의 경우 80.8%~91.4%로 나타났으며 접촉각은 $33.93^{\circ}{\sim}65.70^{\circ}$의 범위로 나타났다. 또한 제조된 콘택트렌즈를 인공누액에 침지시킨 후 측정한 물리적 특성은 함수율 24.46%~48.25%, 굴절률 1.422~1.457 또한 분광투과율의 경우 77.0%~91.0%로 나타났으며 접촉각은 $37.25^{\circ}{\sim}77.33^{\circ}$의 범위로 나타났다. 수화시간에 따른 물성 변화는 굴절률의 증가, 함수율의 감소, 광투과율 감소 및 접촉각의 증가를 나타내었다. 결론: 카르복시메칠 셀룰로오스나트륨을 포함한 인공누액은 친수성 하이드로젤 콘택트렌즈의 함수율, 굴절률, 접촉각 그리고 광투과율에 영향을 주는 것으로 나타났다.

σ, m, p-위치로 치환된 Difluoroaniline을 첨가제로 사용한 안의료용 렌즈 고분자의 물리·광학적 특성 (Opto-Physical Properties of Ophthalmic Lens Polymer Containing σ, m, p-Substituted Difluoroaniline as Additives)

  • 노정원;성아영
    • 한국안광학회지
    • /
    • 제19권1호
    • /
    • pp.69-77
    • /
    • 2014
  • 목적: 본 연구는 플루오로로 치환된 아닐린 (2,4-difluoroaniline, 2,6-difluoroaniline, 3,4-difluoroaniline)을 첨가제로 사용한 기능성 콘택트렌즈를 제조한 후 각각의 물리 광학적 특성을 알아보았다. 방법: 친수성 하이드로젤 콘택트렌즈를 제조하기 위해 HEMA(2-hydroxyethylmethacrylate), NVP(N-vinyl pyrrolidone), MA(methacrylic acid), 교차결합제인 EGDMA(ethylene glycol dimethacrylate), 그리고 개시제인 AIBN(azobisisobutyronitrile)을 기본배합으로 한후, 불소로 치환된 aniline을 첨가하였다. 콘택트렌즈 제조방법은 cast mould법을 사용하여 공중합 하였으며, 제조된 콘택트렌즈는 0.9% NaCl normal saline에 완전히 침지시켜 24시간 수화 후 콘택트렌즈의 물리 광학적 특성을 측정하였다. 결과: 2,4-, 2,6- 및 3,4-difluoroaniline을 비율별로 첨가한 sample의 함수율을 측정한 결과, 첨가제의 비율이 증가할수록 함수율이 감소하는 경향을 나타내었으며, 굴절률의 경우 첨가제의 비율이 증가할수록 함수율과 반비례 하여 굴절률은 증가하는 경향을 나타내었다. 제조된 고분자에 대한 자외선 영역의 광투과율을 측정한 결과, 2,4-difluoroaniline를 첨가제로 사용한 경우, UV-B(9.8~51.4%), UV-A(58.8~79.2%) 그리고 visible transmittance(87.0~90.4%)의 투과율을 나타내었고, 2,6-difluoroaniline를 첨가제로 사용한 sample 렌즈는, UV-B(80.2~83.2%), UV-A(85.8~86.4%), 그리고 visible transmittance(90.8~91.4%)의 투과율을 나타내었다. 또한, 3,4-difluoroaniline를 첨가제로 사용한 고분자 렌즈는, UV-B(3.8~30.4%), UV-A(47.8%~74.4%) 그리고 visible transmittance(86.2~91.0%)의 투과율을 각각 나타내었다. 결론: 본 연구 결과를 통해, 2,4-difluoroaniline 그리고 3,4-difluoroaniline은 자외선 차단성을 지닌 착색 안의료용 렌즈 재료로 유용하게 사용될 수 있을 것으로 판단된다.

써클콘택트렌즈가 눈물막 안정성에 미치는 영향 (The Effect of Circle Contact Lens on the Stability of Tear Film)

  • 이세희;형성민;고승환;박미정;김소라
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.125-131
    • /
    • 2015
  • 목적: 본 연구에서는 써클콘택트렌즈의 착색이 눈물막 안정성에 미치는 영향을 알아보고자 하였다. 방법: 눈물량이 정상인 20대 54안을 대상으로 콘택트렌즈 착용 전후의 비침입성 눈물막파괴시간 및 눈물막 깨짐이 시작되는 부위를 측정하였으며, 콘택트렌즈 전후면의 표면 거칠기를 주사전자현미경으로 관찰하였다. 콘택트렌즈는 hilafilcon B재질의 투명 및 써클콘택트렌즈, polymacon 재질 및 HEMA NVP 공중합 재질의 써클콘택트렌즈를 대상으로 하였다. 결과: 콘택트렌즈 착용 시 나안에 비해 눈물막파괴시간이 통계적으로 유의하게 감소하였으며 써클콘택트렌즈 간에 눈물막파괴시간이 통계적으로 유의한 차이를 보이는 경우도 있었다. 일반적으로 콘택트렌즈의 상방부 보다는 하방부에서, 코방향 보다는 귀방향에서 좀 더 높은 빈도로 눈물막이 깨지기 시작하였으나 렌즈의 종류에 따라 다소 차이가 있었다. Hilafilcon B 투명렌즈에 비해 동일 재질 써클콘택트렌즈 주변부(착색부분)에서의 눈물막 깨짐이 더 많았다. 결론: 써클콘택트렌즈의 착용으로 인해 눈물막 안정성이 영향을 받음을 알 수 있었으며, 본 연구결과는 써클콘택트렌즈 착용 시 착색으로 인하여 나타날 수 있는 문제점 해결의 기초자료로 사용될 수 있을 것으로 보인다.

Preparation of Ag/PVP Nanocomposites as a Solid Precursor for Silver Nanocolloids Solution

  • Hong, Hyun-Ki;Park, Chan-Kyo;Gong, Myoung-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1252-1256
    • /
    • 2010
  • A polyvinylpyrrolidone (PVP)/Ag nanocomposites was prepared by the simultaneous thermal reduction and radical polymerization route. The in situ synthesis of the Ag/PVP nanocomposites is based on the finding that the silver n-propylcarbamate (Ag-PCB) complex can be directly dissolved in the NVP monomer, and decomposed by only heat treatment in the range of 110 to $130^{\circ}C$ to form silver metal. Silver nanoparticles with a narrow size distribution (5 - 40 nm) were obtained, which were well dispersed in the PVP matrix. A successful synthesis of Ag/PVP nanocomposites then proceeded upon heat treatment as low as $110^{\circ}C$. Moreover, important advantages of the in situ synthesis of Ag/PVP composites include that no additives (e.g. solvent, surface-active agent, or reductant of metallic ions) are used, and that the stable silver nanocolloid solution can be directly prepared in high concentration simply by dissolving the Ag/PVP nanocomposites in water or organic solvent.

THERMO-SENSITIVITY OF N-VINYL PYRROLODONE-CO-2- HYDROXYETHYLMETHACRYLATE HYDROGELS

  • Irina Nam;Park, Jung-Ki;Lee, Seong-Nam;Sung, Shi-Joon;Min, Yong-Jin
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 SMICS 2004 International Symposium on Maritime and Communication Sciences
    • /
    • pp.9-15
    • /
    • 2004
  • The copolymerization of HEMA with different hydrophilic and hydrophobic co-monomers allows for the manipulation of their intrinsic properties. 2-Hydroxyethylmethacrylate (HEMA)-based hydrogels thus are of great interest due to their outstanding physico-mechanical properties and chemical stability. The idea to use HEMA in order to create thermo-sensitive polymers was based on our assumption that thermal-sensitivity comes from a suitable hydrophilic-hydrophobic balance of macromolecules. In this work we have chosen N-vinyl pyrrolidone as a hydrophilic co-monomer with the relatively hydrophobic HEMA due to its good polymerizing properties as well as its non-toxicity in a polymer state and deserved recognition as a biocompatible material. As a result, copolymerization of NVP and HEMA was successful in obtaining new types of thermo-sensitive polymers composed of hydrophilic and hydrophobic monomers.

  • PDF

중소벤처기업의 CEO 변혁적 리더십과 내적 외적 혁신 행동이 사업 성과에 미치는 영향에 관한 연구 : 유연적 조직문화의 조절 효과를 중심으로

  • 정운섭;하규수
    • 한국벤처창업학회:학술대회논문집
    • /
    • 한국벤처창업학회 2020년도 춘계학술대회
    • /
    • pp.141-147
    • /
    • 2020
  • 최근 중소기업연구원 연구자료에 의하면 우리나라 중소벤처기업의 혁신 수준은 OECD 최하위 수준이며, 네트워크 기반의 협력체계가 필요하다고 발표하였다. 또한, 최근의 혁신 행동 관련 연구를 살펴보면 내적 혁신 행동에 대한 연구는 많으나, 외부 네트워크 혁신 행동과 연동한 연구는 미진하였다. 따라서 본 연구의 목적은 CEO 변혁적 리더십이 조직 공정성을 기반으로 내적 외적 혁신 행동을 실행함에 있어서 유연적 조직 문화의 조절 효과가 사업성과에 미치는 영향에 대해서 알아보고자 한다. 이론적 고찰을 통해 중소벤처기업 성과모형, CEO 변혁적 리더십, 내적 혁신 행동, 외적 혁신 행동, 조직 공정성, 유연적 조직문화, 사업성과에 대해서 알아보았다. Chrisman 등(1998)의 중소벤처기업 성과모형은 ①기업가(entrepreneur), ②산업구조(industry structure), ③사업전략(business strategy), ④자원(resources), ⑤조직구조(organization structure, processes and systems) 등 5가지를 제시하였다. 본 연구에서는 Chrisman 등(1998)의 벤처기업 성과모형 NVP = f(E, IS, BS, R, OS)을 적용하여 연구 모형을 설계하고 실증 검증하였다. 향후 중소벤처기업 성과모형으로서 직원들의 미래전망과 자부심 향상에 본 연구가 시사점을 제공할 뿐만 아니라 중소벤처기업 경쟁력 강화를 위한 기업 혁신 행동 컨설팅 연구에도 기여할 수 있을 것으로 판단된다.

  • PDF

Expression of DOG1, CD117 and PDGFRA in Gastrointestinal Stromal Tumors and Correlations with Clinicopathology

  • Sun, Xiu-Wei;Feng, Zhan-Jun;Huang, Peng;Hao, Wang;Sui, Xing-Ling
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1389-1393
    • /
    • 2012
  • Objective: To discuss the significance of DOG1, CD117 and PDGFRA in the diagnosis of gastrointestinal stromal tumors (GISTs), and analyze their correlations with clinicopathological features and risk ranking. Method: DOG1, CD117 and PDGFRA were detected with IHC Envision ldpe-g-nvp in 63 GISTs and 43 cases of non-GISTs, and analyzed for relations with clinicopathological factors (gender, age, location, tumor size, mitotic phase, histology) and risk degree. Results: The positive expression rate of DOG1, CD117 and PDGFRA in GISTs was 84.1% (53/63), 90.5% (57/63), 53.2% (33/63), respectively. Among the 6 CD117 negative cases, all were DOG1 positive and 5 were PDGFRA positive. Rates in patients with non-GISTs was 11.6%, 16.3%, 6.98%, respectively. Expression of DOG1 and PDGFRA demonstrated no significant variation with gender, age, position, tumor size, mitotic phase, histology, and risk rank. However, CD117 was related with position and histology (P=0.008 and P=0.045), those in the mesentery having a higher positive rate than those derived from stomach, small intestine, colon and rectum (50.0% vs 94.7%, P=0.008). Furthermore CD117 was also highly expressed in spindle and epithele types. Conclusions: DOG1 had a good sensitivity and specificity as a kind of newly discovered marker, especially for KIT negative GISTs. However, DOG1, CD117 and PDGFRA cannot be used for assessing the rish of patients.

네트워크형 복층 터널 환기 시스템 설계 인자 (Design Factors for the Ventilation System of a Networked Double-deck Tunnel)

  • 박상훈;이승준;박요한;김세민;노장훈;유용호;김진
    • 터널과지하공간
    • /
    • 제26권1호
    • /
    • pp.32-45
    • /
    • 2016
  • 전 세계적으로 도심지 공간의 효율적인 활용을 위한 지하 공간 이용방안에 대해 연구가 진행되어 왔고 미국, 유럽, 중국 등이 복층터널을 건설하여 운영 중이다. 대표적으로, 프랑스의 A86 East, 말레이시아 SMART 터널, 스페인 M30 프로젝트, 미국 시애틀 SR99, 중국 상하이 양쯔강 터널 등을 예로 들 수 있다. 이에 따라서 국내에서도 교통집중을 해소하고 지상 공간 확보를 위해 대심도에 위치하는 네트워크형 복층도로터널 운영에 대한 연구가 진행되고 있다. 그러므로 본 연구에서는 기존에 사용하고 있는 일반적인 도로터널의 환기설계 아웃라인의 리뷰를 통해 대심도 복층터널에 추가적으로 필요한 다양한 요소들을 분석해보고, 해외 복층 도로터널설계사례들을 자세히 검토하여 환기방식과 종류에 따른 환기설계인자분석을 통해 네트워크형 복층 도로터널에 적용 가능한 설계인자를 도출해내고 특징적인 환기설계인자를 새롭게 정립해 본다.

Polymerization and Optical Properties of Polymers with High Tensile Strength Added Isocyanate Group

  • Sung, A-Young;Ye, Ki-Hun
    • 통합자연과학논문집
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Polyurethane resin containing isocyanate is marked by excellent tensile and mechanical strengths and this test aims to gauge its applicability as a medical high polymer. Tris [2-(acryloyloxy)ethyl]isocyanurate and hexamethylenediisocyanate were added to a basic mixing ratio of HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (n-vinyl-2-pyrrolidone) and crosslink agent, EGDMA (ethylene glycol dimethacrylate) with increasing proportions and copolymerized respectively. Also, the basic physical properties of the polymerized high polymers including refraction rate, tensile strength, light transmission and water content were measured to confirm that they are appropriate as hydrogelcontact lenses. After measuring the physical properties of high performance polymers produced by adding tris [2-(acryloyloxy) ethyl]isocyanurate, it was found that the average tensile strengths of sample TRIS1 to TRIS10 were between 0.285 and 0.612 kgf, while the average values of refractive index were ranged from 1.441 to 1.449 with water content from 30.00 to 37.35%.The measurement of physical properties of the copolymers generated by adding hexamethylenediisocyanate showed that the average tensile strength of sample HEXA1 to HEXA10 ranged from 0.267 to 1.742 kgf, the refractive index ranged from 1.443 to 1.475 and water contents were in the range of 21.22 to 35.58%. In all combinations the transmission rates satisfied the transmittance of general hydrogel contact lenses. From theresults, it is possible to conclude that the produced copolymers can be used as contact lens materials with excellent tensile strength.