• Title/Summary/Keyword: NTU

Search Result 315, Processing Time 0.031 seconds

A Study on Coagulation and MF Membrane Process for the Reuse of Sewage Effluent (하수처리장 방류수의 응집 및 정밀여과 처리공정에 관한 연구)

  • Paik, Ke-Jin
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.36-43
    • /
    • 2005
  • Prior to the study of the sewage treatment methods, water quality for Gwangju sewage of fluent was investigated from January to December, 2004 for sewage water reuse. Monthly mean values of BOD, SS, turbidity, total phosphorus and color were 4.1 mg/L, 2.9 mg/L, 0.8 NTU, 1.3 mg/L, and 27 unit, respectively. Jar-test was performed to investigate the removal efficiency of pollutants under the coagulation conditions of fast mixing for 5 min, slow mixing for 15 min and precipitation for 1hr. Here, alum and polyaluminium chloride (PAC) were used as coagulants to reduce color, turbidity, total phosphorus (TP) and total organic carbon (TOC) in sewage effluents. The results showed that PAC gave better efficiency in removing turbidity and dissolved phosphorus than alum. It was also found from the relative molecular weight (RMW) distribution analysis that organic matter over 1,000 Dalton (Da) was easily removed by coagulation and subsequently MF treatment, while it was not effective for less than 500 Da. Based on tis result, Natural organic matter (NOM) with lower molecular weight (< 500 Da) may cause harmful disinfectant by-product (DBP) after chlorine treatment. Thus, activated carbon adsorption seems to be required for the complete removal of DBP in the hybrid system.

Indoor and Outdoor Distribution of Legionella spp and Microbes on Cooling Towers Water of Central Air Conditioning Facilites (중앙집중식 냉방시설의 냉각탑수중 레지오넬라균과 실내외 미생물 분포에 관한 연구)

  • 방선재;이철민;김윤신;선우영
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.39-48
    • /
    • 2002
  • Cooling towers water has frequently been known as a source of infection in outbreaks of Legionnaires' disease and a source of indoor air pollution. However, there have been a few reports on the presence of Legionella in cooling towers water and aerosols of various public facilities. This study was carried out to investigate the indoor and outdoor dis-tribution of Legionella spp and microbe from 132 cooling towers water of public facilities detected 1. pneumophila in Seoul and Gyeonggi-Do areas. The results showed that the Lpneumophila among the selected 132 cooling towers was detected mostly in July (12.0%), followed by August (4.0%) and June, September no-detected. The 1. pneumophiia in public facilities was detected mostly in department store (27.3%), followed by hospital (8.7%), office building (5.9%), big market (5.0%) and hotel, subway no-detected. The pH values of cooling towers water with presence of 1. pneumophila showed mostly 8.0 or higher (9.5%), followed by 7.0~8.0 (6.8%), lower 7.0 no-detected. The tem-perature of cooling towers water with presence of L pnemophila showed mostly 30℃ or higher (9.8%), followed by 26~30℃ (6.9%), lower 25℃ no-detected. The turbidity of cooling towers water with presence of 1. pneumaphila showed mostly 1-2 M (8.8%), followed by above 2 NTU (5.9%), lower 1 NTU no-detected. The correlation coef-ficient between indoor and outdoor concentration of microbes in public facilities showed 0.67 in Legionella spy. (p>0.05), 0.93 in bacteria (p<0.01), 0.94 in fungus (p<0.01), 0.98 in coilform (p<0.01), respectively.

Dynamics of Phytoplankton Community after Formation of Turbid Water in Lake Imha (임하댐의 탁수 형성후 식물플랑크톤 군집 동태)

  • Lee, Kyung-Lak;Choi, Jae-Sin;Kim, Han-Soon;Park, Jung-Won
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.429-434
    • /
    • 2005
  • The dynamics of phytoplankton community after the formatiom of turbidity was assessed at Dam barrage of Lake Imha from May 2003 to July 2004. The maximum turbidity of 1221 NTU during September and October 2003 was well correlated with heavy precipitation caused by Typoon Maemi. A total of 102 phytoplankton taxa was identified and the most abundant phytoplankton group was Bacillariophyceae with 63 taxa, followed by Chlorophyceae with 23 taxa, Cyanophyceae with 9 taxa, 3 taxa each of Synurophyceae and Cryptophyceae and Euglenophyceae with 1 taxon. The total standing crops ranged between 270 indls. $mL^{-1}$ and 4,515 indls. $mL^{-1}$ during the investigation Periods. The three species, Cryptomonas ovata, Cyclotella sp. and Microcystis aeruginosa predominated in sequence after the decrease of turbidity.

Removal of Nitrate and Particulate from Groundwater with Two stage Biofilter system (2단 생물막여과 탈질시스템에서 지하수의 질산성질소 및 입자제거특성)

  • Lee, Moo-Jae;Park, Sang-Min;Jun, Hang-Bae;Kim, Kong-Soo;Lim, Jeoung-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.669-675
    • /
    • 2005
  • Biological nitrate removal from groundwater was investigated in the biofilters packed with both gravel/sand and plastic media. Removal of particles and turbidity were also investigated in the 2-stage biofilter system consisted of biofilter and subsequent sand filter. In the single biofilter packed with gravel and sand, nitrate removal efficiency was dropped with the increase of filtration velocity and furthermore, nitrite concentration increased up to 3.2 mg-N/L at 60 m/day. Denitrification rate at the bottom layer below 25 cm was faster 8 times than upper layer in the up-flow biofilter. Nitrite build-up, due to the deficiency of organic electron donors, occurred at the upper layer of bed. Besides DO concentration and organic carbon, contact time in media was the main factor for nitrate removal in a biofilter. The most of the effluent particles from biofilter was in the range from 0.5 to $2.0{\mu}m$, which resulted in high turbidity of 1.8 NTU. However, sand filter followed by biofilter efficiently performed the removal of particles and turbidity, which could reduce the turbidity of final filtrate below 0.5 NTU. Influent nitrate was removed completely in the 2-stage biofilter and no nitrite was detected.

Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System (DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구)

  • Lee, Byoung Ho;Kim, Sang Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

Analysis of Heat Transfer Performance of a Gas Cooler of CO2 Heat Pump for Water Heating (온수제조용 CO2 히트펌프의 가스쿨러 열전달 성능 해석)

  • Kwon, Jeong-Tae;Lee, Chang-Kyung;Baek, Dong-Seok;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5317-5322
    • /
    • 2013
  • This study presents a prediction method for heat transfer performance of a gas cooler of $CO_2$ heat pump using ${\epsilon}$-NTU method, and compared the results with the experimental data from the open literature. The heat transfer rate, refrigerant side outlet temperature and water side outlet temperature were calculated by using EES(Engineering Equation Solver)program in multi-tube-in-tube type $CO_2$ heat pump gas cooler. Analysis was performed in two methods : The first method performed without dividing into the test section by applying an analysis of the mean properties(mean analysis). The second method, tube length divided into 50 sections, was applied to the local properties(local analysis). From the present study, a good agreement at the local analysis was obtained between the analytical and experimental results by 0.3~1.1%, 1.31~1.88% and 3.12~5.18% for heat transfer rate, water and refrigerant side outlet temperatures, respectively.

Cryptosporidium Oocyst Detection in Water Samples: Floatation Technique Enhanced with Immunofluorescence Is as Effective as Immunomagnetic Separation Method

  • Koompapong, Khuanchai;Sutthikornchai, Chantira;Sukthana, Yowalark
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.4
    • /
    • pp.353-357
    • /
    • 2009
  • Cryptosporidium can cause gastrointestinal diseases worldwide, consequently posing public health problems and economic burden. Effective techniques for detecting contaminated oocysts in water are important to prevent and control the contamination. Immunomagnetic separation (IMS) method has been widely employed recently due to its efficiency, but, it is costly. Sucrose floatation technique is generally used for separating organisms by using their different specific gravity. It is effective and cheap but time consuming as well as requiring highly skilled personnel. Water turbidity and parasite load in water sample are additional factors affecting to the recovery rate of those 2 methods. We compared the efficiency of IMS and sucrose floatation methods to recover the spiked Cryptosporidium oocysts in various turbidity water samples. Cryptosporidium oocysts concentration at 1, $10^1$, $10^2$, and $10^3$ per $10{\mu}l$ were spiked into 3 sets of 10 ml-water turbidity (5, 50, and 500 NTU). The recovery rate of the 2 methods was not different. Oocyst load at the concentration < $10^2$ per 10 ml yielded unreliable results. Water turbidity at 500 NTU decreased the recovery rate of both techniques. The combination of sucrose floatation and immunofluorescense assay techniques (SF-FA) showed higher recovery rate than IMS and immunofluorescense assay (IMS-FA). We used this SF-FA to detect Cryptosporidium and Giardia from the river water samples and found 9 and 19 out of 30 (30% and 63.3%) positive, respectively. Our results favored sucrose floatation technique enhanced with immunofluorescense assay for detecting contaminated protozoa in water samples in general laboratories and in the real practical setting.

Characteristics of Depth Filtration for Various Filter-Bed Configurations (심층여과지의 여층구성에 따른 여과특성 비교)

  • An, Jong-Ho;Yun, Jae-Heung
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.459-472
    • /
    • 2001
  • The objective of this study is to evaluate the filtration efficiency of deep-bed filters by comparing to single and dual media filters. Pilot-plant tests using four-filter columns were conducted for the comparison of head loss development and filtered water quality. The dual-media filter showed greater initial head loss, but less rate of head-loss development than those of the coarse-sand-0deep-bed filters. For 180 m/day of filtration rate, the dual-media filter produces larger unit production rate by 30-40%, and the turbidities of filtered water were below 0.1 NTU. The initial breakthrough could be effectively controlled by the dual-media filter rather than coarse-sand-deep-bed filters.

  • PDF

Prolonged Turbidity of the Lower Nakdong River in 2003

  • Kim, Dong-Kyun;Kim, Hyun-Woo;Kim, Gu-Yeon;Kim, Young-Sang;Kim, Myoung-Chul;Jeong, Kwang-Seuk;Joo, Gea-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.spc
    • /
    • pp.44-53
    • /
    • 2005
  • The Nakdong River, which lies in a monsoon climate zone with warm rainy summers and cold dry winters, is a typical ecosystem showing the attributes of a regulated river. In 2003, the total annual rainfall (1,805 mm) was higher than the average of the past nine years from 1994 to 2002 (1,250 mm). In September a powerful typhoon, Maemi, caused a big impact on the limnology of the river for over two months. Among the limnological variables, turbidity in 2003 (37.4 ${\pm}$ 94.1 NTU, n = 54) was higher than the annual average for ten years (18.5 ${\pm}$ 2.3 NTU, n = 486) in the lower part of the river (Mulgum: RK 28). Furthermore, physical disturbance (e.g. stream bank erosion within channel) in the upstream of the Imha Dam (RK ca. 350; river distance in kilometer from the estuary barrage) in the upper part of the river was a source of high turbidity, and impacted on the limnological dynamics along a 350 km section of the middle to lower part of the river. After the typhoon, high turbidity persisted more than two months in the late autumn from September to November in 2003. Flow regulation and the extended duration of turbid water are superimposed on the template of existing main channel hydroecology, which may cause spatial changes in the population dynamics of plankton in the river.

A Pilot-Scale Microfiltration/Ultrafiltration system for Drinking Water Treatment (상수처리를 위한 파일롯 규모의 정밀여과/한외여과 시스템)

  • Kim, Hanseung;Oh, Jeongik;Kim, Chunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.770-777
    • /
    • 2004
  • Three pilot-scale membrane systems were operated using lake water as influent in this study. Microfiltration (MF) membrane with pore size of 0.01 m was used in Systen I of which filtration mode was set at constant pressure of $1kgf/cm^2$. Ultrafiltration (UF) membranes with molecular cutoff (MWCO) of 80,000 and 13,000 were used in System II-1 and II-2, respectively. Constant flow mode was applied at the range between 0.7 and $1.5m^3/m^2{\cdot}d$ (average of $1.1m^3/m^2${\cdot}d) for System II-1 and between 0.37 and $1.65m^3/m^2{\cdot}d$ (average of $1.18m^3/m^2{\cdot}d$) for System II-2. In System I, the flux changed from $1m^3/m^2{\cdot}d$ to $0.2m^3/m^2{\cdot}d$ during the operation time of 5 months. System II showed recovery of 94% under the allowable maximum pressure of $3kgf/cm^2$ during the same operation period. From these results, the efficient operation was observed in constant flow mode with respect to filtration time and recovery. Average filtrate turbidity showed 0.0071 NTU in System I and 0.0054 NTU in System II, which implied that high turbidity removal was obtained in both MF and UF systems with no significant difference between MF and UF. From the fact that membrane flux depends largely on membrane type and operation mode, a guideline of optimum design and operation should be suggested for application of membrane systems to full scale water treatment.